Laserfiche WebLink
DEAN TRAN RESIDENCE <br />2004 PICASSO, SANTA ANA, CA 92704 <br />PHONE: 714-606-3502 <br />EMAIL: jamesdeanofmath@gmail.com <br />APN: 412-551-14 <br />SHEET SIZE SHEET NAME <br />5628 BALDWIN AVE. <br />TEMPLE CITY, CA 91780 <br />PHONE NO.:626-353-4787 <br />LICENSE TYPE: B, C-46 ; LICENSE #: 1007552 <br />info@brightspotsolar.com <br />REVISIONS <br />REVDATE DESCRIPTION <br />SHEET NUMBER <br />E 1.2 <br />ANSI B <br />11" X 17" <br />R04/13/2023 DRAFT REVIEW <br />SYSTEM SIZE: 2.160 kW DC <br />1.740 kW AC <br />MODULE TYPE & AMOUNT: (6) LONGI SOLAR LR4-60-HPB-360M <br />MODULE DIMENSIONS: (L/W/H) 69.9"/41.41"/1.38" <br />INVERTER: (6) ENPHASE ENERGY IQ8PLUS-72-2-US [240V][SI1-SB] <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />EE NOTES <br />SITE NOTES: <br />1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. <br />2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE <br />BATTERIES. <br />3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. <br />4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER <br />SECTION CEC 110.26. <br />5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED <br />MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. <br />EQUIPMENT LOCATIONS: <br />1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY CEC 110.26. <br />2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY CEC 690.31 <br />(A),(C) AND CEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). <br />3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC 690.34. <br />4. ADDITIONAL AC DISCONCECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONCECT. <br />2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CEC APPLICABLE CODES. <br />5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. <br />STRUCTURAL NOTES: <br />1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A <br />DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY <br />/ SUBARRAY, ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS. <br />2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED <br />PER LOCAL REQUIREMENTS. <br />3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A <br />LICENSED CONTRACTOR. <br />4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING <br />MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING <br />MEMBERS. <br />WIRING & CONDUIT NOTES: <br />1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON <br />MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. <br />2. CONDUCTORS SIZED ACCORDING TO CEC 690.8, CEC 690.7. <br />3. VOLTAGE DROP LIMITED TO 1.5%. <br />4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY <br />W/ SUITABLE WIRING CLIPS. <br />5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE <br />PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONCECTED <br />SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [CEC 110.15]. <br />GROUNDING NOTES: <br />1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS <br />SHALL BE RATED FOR SUCH USE. <br />2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO CEC 690.43 AND MINIMUM CEC TABLE 250.122. <br />3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND <br />250.136(A). <br />4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45 AND MICRO INVERTER MANUFACTURERS’ <br />INSTRUCTIONS. <br />5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND <br />APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG <br />HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. <br />6. THE GROUNDING CONCECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OFA MODULE DOES NOT INTERRUPT A <br />GROUNDING CONDUCTOR TO ANOTHER MODULE. <br />7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER <br />[CEC 250.119] <br />8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 AND CEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS <br />INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC 250, CEC 690.47 AND AHJ. <br />9. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS <br />DISCONCECTION AND OVER-CURRENT PROTECTION NOTES: <br />1. DISCONCECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED <br />ARE CONCECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). <br />2. DISCONCECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH <br />3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR <br />EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D). <br />4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8, 690.9, AND 240. <br />5. MICRO INVERTER BRANCHES CONCECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH CEC 110.3(B). <br />6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. <br />INTERCONCECTION NOTES: <br />1. LOAD-SIDE INTERCONCECTION SHALL BE IN ACCORDANCE WITH [CEC 705.12 (B)] <br />2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUS BAR RATING [CEC <br />705.12(D)(2)(3)]. <br />3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE <br />PROTECTING THE BUS BAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUS BAR, PV DEDICATED BACKFEED BREAKERS <br />MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [CEC 705.12(B)(2)(3)]. <br />4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO CEC 705.12 (B)(2)(3)(C). <br />5. FEEDER TAP INTERCONCECTION (LOADSIDE) ACCORDING TO CEC 705.12 (B)(2)(1) <br />6. SUPPLY SIDE TAP INTERCONCECTION ACCORDING TO CEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH <br />CEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [CEC <br />705.12 (B)(5)]. <br />2004 W Picasso - <br />2018062008/29/23