Laserfiche WebLink
JB <br />JB <br />N <br />DEAN TRAN RESIDENCE <br />2004 PICASSO, SANTA ANA, CA 92704 <br />PHONE: 714-606-3502 <br />EMAIL: jamesdeanofmath@gmail.com <br />APN: 412-551-14 <br />SHEET SIZE SHEET NAME <br />5628 BALDWIN AVE. <br />TEMPLE CITY, CA 91780 <br />PHONE NO.:626-353-4787 <br />LICENSE TYPE: B, C-46 ; LICENSE #: 1007552 <br />info@brightspotsolar.com <br />REVISIONS <br />REVDATE DESCRIPTION <br />SHEET NUMBER <br />E 1.3 <br />ANSI B <br />11" X 17" <br />R04/13/2023 DRAFT REVIEW <br />SYSTEM SIZE: 2.160 kW DC <br />1.740 kW AC <br />MODULE TYPE & AMOUNT: (6) LONGI SOLAR LR4-60-HPB-360M <br />MODULE DIMENSIONS: (L/W/H) 69.9"/41.41"/1.38" <br />INVERTER: (6) ENPHASE ENERGY IQ8PLUS-72-2-US [240V][SI1-SB] <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />WARNING LABELS <br />UTILITY METER & <br />MAIN PANEL <br />PICASSO <br />LOCATION: <br />CODE REF: <br />AC DISCONNECT <br />UTILITY15 <br />UTILITY AC DISCONNECT <br />SWITCH <br />LOCATION: <br />CODE REF: <br />MAIN PANEL:(EXTERIOR) <br />PV BREAKER: (INTERIOR) <br />CEC 705.12(B)(2)(3)(B) <br />PV SOLAR BREAKER <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE16 <br />LOCATION: BACKFED BREAKER <br />CODE REF: CEC 705.12(4)1 CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />! <br />LOCATION: BACKFED BREAKER <br />CODE REF: 2017 CEC 705.12(2)(3)(b) 2 <br />WARNING <br />INVERTER OUTPUT CONCECTION: <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />! <br />5 <br />LOCATION: MAIN PANEL (EXTERIOR) <br /> PV BREAKER (INTERIOR) <br />CODE REF: CEC 690.56(C)(3) <br />RAPID SHUTDOWN <br />SWITCH FOR <br />SOLA R PV SYSTEM <br />6 <br />LOCATION: <br />CODE REF: <br />COMBINER PANEL <br />AC DISCONNECT <br />JUNCTION BOX <br />INVERTER(S) <br />CEC 690.13(B) <br />WARNING ! <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />8 <br />LOCATION: AC COMBINER PANEL <br />CODE REF: CEC 690.13(B) <br />WARNING <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />DO NOT ADD LOADS <br />! <br />9 <br />LOCATION: <br />CODE REF: <br />DC DISCONNECT <br />INVERTER <br />UTILITY <br />480VDC <br />15.0ADC <br />MAXIMUM VOLTAGE: <br />MAXIMUM CIRCUIT CURRENT: <br />MAX. RATED OUTPUT CURRENT OF <br />THE CHARGE CONTROLLER OR DC- <br />TO-DC- CONVERTER (IF INSTALLED)15.0ADC <br />PHOTOVOLTAIC SYSTEM DC DISCONNECT <br />10 <br />LOCATION: DC DISCONNECT, COMBINE BOX <br />CODE REF: CEC 690.13(B) <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />WARNING! <br />11 <br />LOCATION: <br />CODE REF: <br />YELLOW STICKER <br />MAIN SERVICE (OUTSIDE COVER) <br />CEC 690.12 <br />CEC 690.56(C)(1)(a) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />SOLAR ELECTRIC <br />PV PANELS <br />12 <br />LOCATION: <br />CODE REF: <br />REFLECTIVE AND WEATHER RESISTANT <br />DC CONDUIT <br />JUNCTION BOX <br />NO MORE THAN 10FT <br />CEC 690.31(G)(3) <br />CEC 690.31(G)(4) <br />WARNING PHOTOVOLTAIC POWER SOURCE <br />LABEL REQUIRES CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8 INCH, WHITE LETTERS ON RED BACKGROUND <br />LABELS SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES <br />EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF <br />ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS. <br />LOCATION: SERVICE METER <br />MAIN PANEL13DUAL POWER SOURCE <br />SECOND SOURCE IS <br />PHOTOVOLTAIC <br />CAUTION! <br />7 LOCATION: <br />CODE REF: <br />DEDICATED KWH METER <br />CEC 690.4(B) UTILITY DEDICATED DER METER LOCATION: <br />CODE REF: <br />(IF APPLICABLE) <br />SERVICE PANEL <br />CEC 705.12(7)14 <br />WARNING <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />INVERTER OUTPUT CONCECTION <br />! <br />3 <br />LOCATION: <br />CODE REF: <br />(IF APPLICABLE) <br />SUPPLY SIDE TAP <br />LOAD PANEL <br />UTILITY <br />WARNING <br />A GENERATION SCOURCE IS CONCECTED TO THE SUPPLY <br />(UTILITY) SIDE OF THE MAIN SERVICE DISCONNECT. FOLLOW <br />THE PROPER LOCK-OUT/TAG-OUT PROCEDURES TO ENSURE <br />THE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH IS <br />OPENED PRIOR TO PERFORMING WORK ON THIS DEVICE <br />CAUTION <br />POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONCECTS LOCATED AS SHOWN <br />! ! <br />ENPHASE <br />COMBINER BOX <br />4 <br />LOCATION: <br />CODE REF: <br />MAIN PANEL <br />AC DISCONNECT(S) <br />CEC 690.54 <br />PHOTOVOLTAIC AC DISCONNECT <br />RATED AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />29.7A AC <br />240VAC <br />2004 W Picasso - <br />2018062008/29/23