Laserfiche WebLink
DEAN TRAN RESIDENCE <br />2004 PICASSO, SANTA ANA, CA 92704 <br />PHONE: 714-606-3502 <br />EMAIL: jamesdeanofmath@gmail.com <br />APN: 412-551-14 <br />SHEET SIZE SHEET NAME <br />5628 BALDWIN AVE. <br />TEMPLE CITY, CA 91780 <br />PHONE NO.:626-353-4787 <br />LICENSE TYPE: B, C-46 ; LICENSE #: 1007552 <br />info@brightspotsolar.com <br />REVISIONS <br />REVDATE DESCRIPTION <br />SHEET NUMBER <br />PV 0.0 <br />ANSI B <br />11" X 17" <br />R04/13/2023 DRAFT REVIEW <br />SYSTEM SIZE: 2.160 kW DC <br />1.740 kW AC <br />MODULE TYPE & AMOUNT: (6) LONGI SOLAR LR4-60-HPB-360M <br />MODULE DIMENSIONS: (L/W/H) 69.9"/41.41"/1.38" <br />INVERTER: (6) ENPHASE ENERGY IQ8PLUS-72-2-US [240V][SI1-SB] <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />SYSTEM SIZE: 2.160 kW DC <br />1.740 kW AC <br />MODULE TYPE & AMOUNT: (6) LONGI SOLAR LR4-60-HPB-360M <br />MODULE DIMENSIONS: (L/W/H) 69.9"/41.41"/1.38" <br />INVERTER: (6) ENPHASE ENERGY IQ8PLUS-72-2-US [240V][SI1-SB] <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />APPROVALS - FOR AHJ AND OFFICIAL USE ONLY <br />NOTES <br />EQUIPMENT LOCATION <br />1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY CEC 110.26. <br />2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING <br />TEMPERATURE AS SPECIFIED BY CEC690.31(A),(C) AND CEC TABLES 310.15(B)(2)(A) AND <br />310.15(B)(3)(C). <br />3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC <br />690.34. <br />4. ADDITIONAL AC DISCONCECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN <br />SIGHT OF THE AC SERVICING DISCONCECT. <br />5. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO <br />CEC APPLICABLE CODES. <br />6. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN <br />APPROPRIATE. <br />WIRING & CONDUIT NOTES <br />1. ALL CONDUITS AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT <br />AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT <br />MEANT TO LIMIT UP-SIZING. <br />2. CONDUCTORS SIZED ACCORDING TO CEC 690.8, CEC 690.7. <br />3. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE <br />LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. <br />4. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK, PHASE B OR <br />L-2 RED, OR OTHER CONVENTION IF THREE PHASE, PHASE C OR L3-BLUE, YELLOW, ORANGE, <br />OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONCECTED SYSTEMS <br />THE PHASE WITH THE HIGHER VOLTAGE TO BE MARKED ORANGE CEC 110.15. <br />GENERAL NOTES <br />1. MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE <br />STANDARDS. <br />2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE <br />STANDARDS. <br />3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL <br />ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION <br />MIGHT VARY. <br />4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT <br />WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. <br />5. ALL GROUND WIRING CONCECTED TO THE MAIN SERVICE GROUNDING <br />IN MAIN SERVICE PANEL/SERVICE COMPONENT. <br />6. ALL CONDUCTORS SHALL BE 600V, 75° C STANDARD COPPER UNLESS <br />OTHERWISE NOTED. <br />7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN <br />COMPLIANCE WITH OSHA REGULATIONS. <br />8. THE SYSTEM WILL NOT BE INTERCONCECTED BY THE CONTRACTOR <br />UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. <br />9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT <br />REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS <br />SUCH AS WINDOWS WHERE THE ACCESS POINT DOES NOT CONFLICT <br />WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. <br />10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM <br />ARRAY WIRING TO CONDUIT WIRING. <br />11. CONDUIT TO BE PAINTED TO MATCH EXTERIOR SURFACE COLOR. <br />SHEET INDEX: <br />PV 0.0: COVER SHEET <br />PV 1.0: PLOT PLAN <br />PV 1.1: SITE PLAN <br />PV 1.2: ROOF PLAN <br />S 1.1: MOUNT DETAILS <br />E 1.1: LINE DIAGRAM <br />E 1.2: EE NOTES <br />E 1.3: WARNING LABELS <br />DS: EQUIPMENT SPEC SHEET <br />GOVERNING CODES <br />ALL WORK SHALL CONFORM TO THE FOLLOWING CODES <br />· 2022 CALIFORNIA BUILDING CODE <br />· 2022 CALIFORNIA RESIDENTIAL CODE <br />· 2022 CALIFORNIA MECHANICAL CODE <br />· 2022 CALIFORNIA PLUMBING CODE <br />· 2022 CALIFORNIA ENERGY CODE <br />· 2022 CALIFORNIA HISTORICAL BUILDING CODE <br />· 2022 CALIFORNIA EXISTING BUILDING CODE <br />· 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />· 2022 CALIFORNIA FIRECODE <br />· 2022 CALIFORNIA ELECTRICAL CODE <br />JURISDICTION : CITY OF SANTA ANA <br />DEAN TRAN RESIDENCE <br />SCALE: NTS <br />1 AERIAL VIEW <br />PV 0.0 SCALE: NTS <br />2 VICINITY MAP <br />PV 0.0 <br />COVER SHEET <br />2004 PICASSO, SANTA ANA, CA 92704 <br />PHONE: 714-606-3502 <br />EMAIL: jamesdeanofmath@gmail.com <br />APN: 412-551-14 <br />BLDG# 101116243 ISS. 08/24/2023 <br />ELEC# 20180620 ISS. 08/24/2023 <br />The scope of the plans is for the installation of the <br />solar photovoltaic system only and the approval is <br />subject to compliance with all applicable city and <br />state codes and regulations regarding construction. <br />The approval of the plans does not constitute any <br />certification of the accuracy, completeness, or <br />building permit status of the existing buildings and <br />structures as shown. <br />2004 W Picasso - <br />2018062008/29/23