Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
<br /> Code Compliance Research Report CCRR-0456 Page 3 of 9 <br /> <br /> <br /> <br /> <br /> <br /> 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 <br /> intertek.com/building <br /> <br />PCA-101 <br />Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report <br /> <br />placement of the adjacent modules. When adjacent to <br />asphalt shingles, the GAF Energy Step Flap must be installed <br />2 inches above the reveal line and must be nailed with two <br />nails, one in each upper corner. <br /> <br />Penetrations in the roof deck may occur only in the sections <br />of the roof covering where the asphalt shingles are located. <br />Penetrations must be flashed in accordance with applicable <br />code requirements. <br /> <br />6.0 CONDITIONS OF USE <br /> <br />6.1 Installation must comply with this Research Report, the <br />manufacturer’s published installation instructions, and the <br />applicable Code. In the event of a conflict, this report <br />governs. <br /> <br />6.2 The Timberline Solar BIPV Roofing System is <br />manufactured under a quality control program with <br />inspections by Intertek Testing Services NA, Inc. <br /> <br />7.0 SUPPORTING EVIDENCE <br /> <br />7.1 Reports of tests in accordance with UL 7103, UL 61730 <br />(1 & 2), ASTM E108, UL 790, ASTM D3161, TAS 100, TAS 107, <br />UL 2218, UL 3741 and UL 1703 Section 30. <br /> <br />7.2 Intertek Listing Report "GAF Energy LLC - Timberline <br />Solar BIPV Roofing System", on the Intertek Directory of <br />Building Products. <br /> <br />7.3 Intertek Listing Report “Photovoltaic Hazard Control” <br />on the Intertek Directory of Listed Products. <br /> <br />7.4 Intertek Listing Report “Photovoltaic Module Safety <br />Qualification Part 1 Requirements for Construction” on the <br />Intertek Directory of Listed Products. <br /> <br />8.0 IDENTIFICATION <br /> <br />The GAF Energy LLC Timberline Solar BIPV Roofing System is <br />identified with the manufacturer’s name, the product name, a <br />label indicating listing to UL 7103 and UL 61730 (1 & 2), the <br />Intertek Mark as shown below, the Intertek Control Number <br />and the Code Compliance Research Report number (CCRR- <br />0456). Packaging labels shall also include reference to TAS 107 <br />and ASTM D3161, Class F. <br /> <br /> <br /> <br /> <br /> <br /> <br />9.0 OTHER CODES <br /> <br />9.1 Florida Building Code: <br /> <br />The Timberline Solar BIPV Roofing System, described in <br />Sections 2.0 through 7.0 of this Research Report, complies <br />with the 2023 and 2020 Florida Building Code – Building <br />and Florida Building Code – Residential, including High- <br />velocity Hurricane Zones (HVHZ). <br /> <br />Intertek is an approved evaluation entity and quality <br />assurance entity pursuant to Florida Statute 553.842 – <br />Product Evaluation and Approval. <br /> <br />9.2 National Electric Code: <br /> <br />Timberline Solar, in combination with the Delta Electronics <br />components and components that are listed under the user <br />manual revision of Rev 2.1 has been evaluated as a system <br />to the requirements in ANSI/CAN UL 3741 Photovoltaic <br />Hazard Control. When installed in accordance with <br />manufacturer’s installation instructions and this report, this <br />its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than <br />to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit <br />copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and <br />understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of <br />the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification <br />and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale <br />2006 N Deodar St - 101118000 & <br />20181911 <br />6/11/2024