My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 W 19th St - Plan
PBA
>
Building
>
ProjectDox
>
N
>
Nineteenth St
>
210 W Nineteenth St
>
210 W 19th St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:00 PM
Creation date
6/1/2025 12:01:21 PM
Metadata
Fields
Template:
Plan
Permit Number
20182849
30147263
40139112
101119348
101119349
Full Address
210 W Nineteenth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1235674 <br />4' - 0"27' - 0"19' - 9"15' - 10"24' - 10"6' - 2" <br />A <br />B1 <br />B <br />E <br />9' <br /> <br />- <br /> <br />0 <br />" <br />6' <br /> <br />- <br /> <br />9 <br />" <br />3' <br /> <br />- <br /> <br />8 <br />" <br />9' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />9' <br /> <br />- <br /> <br />6 <br />" <br />D <br />2 <br />A5.1 <br />1 <br />A5.1 <br />97' - 7" <br />9' - 2"8' - 6"9' - 4"4' - 0"23' - 4"10' - 6"10' - 6"12' - 2" <br />38 <br />' <br /> <br />- <br /> <br />9 <br />" <br />8' <br /> <br />- <br /> <br />1 <br />" <br />8' <br /> <br />- <br /> <br />2 <br />" <br />7' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />7' <br /> <br />- <br /> <br />6 <br />" <br />16 <br />' <br /> <br />- <br /> <br />3 <br />" <br />22 <br />' <br /> <br />- <br /> <br />6 <br />" <br />13' - 2"10' - 6"18' - 10"10' - 6"10' - 6"7' - 10"12' - 7"7' - 6" <br />71' - 4"20' - 1"3' - 2" <br />6' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />6' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />6 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />6 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />AD1 <br />6 <br />C <br />3A <br />38 <br />' <br /> <br />- <br /> <br />9 <br />" <br />1 <br />7 <br />8 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />11 1 <br />11 <br />1 <br />EGRESS STAIRCASE 2EGRESS STAIRCASE 2 <br />EGRESSEGRESS <br />STAIRCASE 1STAIRCASE 1 <br />UNISEX 2UNISEX 2 <br />OPEN OFFICE 2OPEN OFFICE 2 <br />A5.2 <br />8 <br />A5.2 <br />3 <br />111 <br />8 <br />10 <br />10 <br />12 <br />4: <br />1 <br />2 <br />4:12 <br />4:12 <br />13 <br />13 <br />9'-0" CLG. <br />8'-0" CLG.14 <br />7 <br />7 <br />5' - 0" <br />9 <br />1-HR FIRE RATED WALL. REFER TO 1/AD3 <br />(N) 2x WOOD STUD WALL <br />TEMPERED GLASS <br />1 <br />2 <br />(N) STRUCTURE COLUMN. REFER TO STRUCTURE DWG. <br />3 <br />4 <br />(N) BIKE RACK <br />5 <br />(N) ISA SIGN AT 60 AF.F PER NOTE ON SHEET A0.026 <br />(N) TACTILE EXIT SIGN. REFER TO DETAIL 1/AD17 <br />DASHLINE INDICATES AWNING ABOVE8 <br />METAL GATE WITH PRE-FIN. CORRUGATED METAL PANELS9 <br />DASHLINE INDICATES ROOFLINE ABOVE <br />(N) AC OUTDOOR UNIT. REFER TO MECHANICAL DWG. <br />(N) CONCRETE SLAB <br />(N) ACCESSIBLE PATH OF TRAVEL 5% MAX SLOPE, 2% MAX CROSS SLOPE <br />DASHLINE INDICATES 2ND LEVEL ABOVE <br />10 <br />11 <br />(N) AWNING12 <br />(N) ASPHALT SHINGLE ROOF COVERING SYSTEM PER ICC-ESR-3267, <br />MANUFACTURE: OAKRIDGE SHINGLE, ESTATE GRAY LAMINATED ARCHITECTURAL ROOF <br />SHINGLES CLASS "A" OR BETTER. ROOF COVERING OVER FLASHING OVER 2 LAYERS <br />OF #15 ROOF FELT OVER 1/2" CDX PLYWOOD SHEATHING. <br />13 <br />(N) ATTIC ACCESS LADDER14 <br />(N) 400AMP ELECTRICAL PANEL15 <br />ENTRY DOOR <br />EXTERIORA SINGLE PANEL <br />INTERIORB <br />SINGLE HUNG WINDOW <br />EXTERIORA <br />SEE SCHEDULE SEE SCHEDULE <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />VA <br />R <br />I <br />E <br />S <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />JOB# <br />DATE <br />DRAWN <br />SCALE <br />Th <br />i <br />s <br /> <br />D <br />u <br />c <br />o <br />u <br />m <br />e <br />n <br />t <br /> <br />i <br />s <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />Y <br />N <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C <br />. <br />, <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br />n <br />o <br />t <br /> <br />be <br /> <br />r <br />e <br />p <br />o <br />r <br />d <br />u <br />c <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />c <br />o <br />n <br />s <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />Y <br />N <br />G <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C. <br />© <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />No. C-32798 <br />HC <br />F <br />RADSEN <br />E <br />S <br />TAT <br />LCAIOF <br />EILC <br />A <br />ORNI <br />TC <br />ITEYENNY NG <br />DATERENEWAL <br />03-31-25 <br />As indicated <br />A2.2 <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />S <br />E <br />C <br />O <br />N <br />D <br />FL <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />YC23005 <br />AN <br />C <br />E <br />N <br />A <br />Y <br /> <br />C <br />O <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />JAN 2024 <br />T.N. <br />21 <br />0 <br /> <br />W <br />. <br /> <br />1 <br />9 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />SCALE <br /> 1/4" = 1'-0"1PROPOSED SECOND FLOOR PLAN <br />SYMBOL LEGENDSDOOR AND WINDOW TYPES <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />1 <br />07 <br />/ <br />3 <br />1 <br />/ <br />2 <br />0 <br />2 <br />4 <br />2N <br />D <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />2 <br />9/ <br />1 <br />6 <br />/ <br />2 <br />0 <br />2 <br />4 <br />3R <br />D <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />3 <br />10 <br />/ <br />0 <br />1 <br />/ <br />2 <br />0 <br />2 <br />4 <br />OC <br />F <br />A <br /> <br />R <br />E <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />4 <br />10 <br />/ <br />1 <br />7 <br />/ <br />2 <br />0 <br />2 <br />4 <br />4T <br />H <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />DOOR SCHEDULE <br />NUMBER TYPE SIZE MATERIAL DESCRIPTION <br />1 A 3'-0" x 8'-0"WOOD FRAME, GLASS PANELLED FRONT ENTRANCE <br />2 A 3'-0" x 8'-0"WOOD FRAME, GLASS PANELLED STAIRCASE 1, 1-HR FIRE RATED, TEMPERED GLASS <br />3 A 3'-0" x 8'-0"WOOD FRAME, GLASS PANELLED SIDE ENTRANCES, 1-HR FIRE RATED, TEMPERED GLASS <br />4 A 3'-0" x 8'-0"WOOD FRAME, GLASS PANELLED STAIRCASE 2, 1-HR FIRE RATED, TEMPERED GLASS <br />5 B 3'-0" x 8'-0"WOOD FRAME, HOLLOW CORE UNISEX 1 <br />6 C (2) 5'-3"x5'-0"CORRUGATED METAL PANELS TRASH ENCLOSURE <br />7 A 3'-0" x 8'-0"WOOD FRAME, GLASS PANELLED STAIRCASE 1, 1-HR FIRE RATED, TEMPERED GLASS <br />8 B 3'-0" x 8'-0"WOOD FRAME, HOLLOW CORE UNISEX 2 <br />9 A 3'-0" x 8'-0"WOOD FRAME, GLASS PANELLED STAIRCASE 2, 1-HR FIRE RATED, TEMPERED GLASS <br />WINDOW SCHEDULE <br />NUMBER TYPE COUNT SIZE HEAD HEIGHT MATERIAL U-VALUE SHGC DESCRIPTION <br />1 A 28 3'-6"x6'-0"8' - 10"DOUBLE GLAZE 0.46 0.22 <br />2 A 2 3'-0"x6'-0"8' - 10"DOUBLE GLAZE 0.46 0.22 <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />DOOR: <br />EXIT SIGNS SHALL BE 6" MINIMUM HIGH LETTERS ON CONTRASTING BACKGROUND <br />LOCATED ABOVE EXITS. <br />DOOR HARDWARE SHALL BE MOUNTED AT 34" - 44" ABOVE FLOOR LEVEL. <br />PROVIDE LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR <br />OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY <br />TO GRASP THE OPENING HARDWARE <br />THRESHOLD SHALL BE NO HIGHER THAN 1/2" ABOVE THE FLOORING EDGES TO BE <br />BEVELED WITH A SLOPE NO GREATER THAN 1:2 IF THICKER THAN 1/2" <br />ALL GLAZING WITHIN 12" OF DOOR AND 18" ABOVE FLOOR SHALL BE TEMPERED <br />DOOR OPERATIONS: ALL EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT KEY <br />SPECIAL KNOWLEDGE OR EFFORT. THE UNLATCHING ENY EXIT DOOR SHALL NOT <br />REQUIRE MORE THAN ONE OPERATION. <br />LOCKS AND LATCHES: THE LOOKING DEVICE FOR THE MAIN EXTERIOR EXIT DOOR(S) <br />SHALL BE READILY DISTINGUISHABLE AS LOCKED. <br />DOOR SHALL ALSO HAVE A VISIBLE SIGN STATING: "THIS DOOR TO REAMIN UNLOCKED <br />WHEN BUILDING IS OCCUPIED." THE SIGN SHALL BE IN LETTERS ONE INCH HIGH ON <br />CONTRASTING BACKGROUND (ABOVE THE DOOR; POSTED ON THE EGRESS SIDE OR <br />ADJACENT TO THE DOOR <br />WINDOW: <br />GLASS AND GLAZING SHALL COMPLY WITH CBC CHAPTER 24 <br />GLASS AND GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH THE <br />REQUIREMENTS OF CBC SECTION 2406 AND TABLES 24-C AND 24-D <br />GLASS SHALL BE FIRMLY SUPPORTED ON ALL FOUR EDGES (CBC 2401.1) <br />FIELD MEASURE ALL OPENINGS PRIOR TO FABRICATION <br />SAFETY GLAZING IS REQUIRED FOR GLAZING IN DOORS, WINDOWS WITHIN 24" OF <br />DOOR, WITHIN 18" OF THE FLOOR, OR WITHIN 36" OF WALKING SURFACES MEASURED <br />HORIZONTALLY. <br />ALL SAFETY GLAZING SHALL COMPLY WITH IMPACT TEST IN ACCORDANCE WITH CPSC <br />16 CFR PART 1201 <br />GENERAL NOTESDOOR AND WINDOW SCHEDULES KEYNOTES <br />4 <br />210 W 19th St <br />4/14/2025
The URL can be used to link to this page
Your browser does not support the video tag.