DN <br />DN <br />1235674 <br />A <br />B1 <br />B <br />E <br />D <br />2 <br />A5.1 <br />1 <br />A5.1 <br />TRASH ENCLOSURE <br />COVERED <br />PORCH <br />EGRESS STAIRCASE 2 <br />EGRESS STAIRCASE 1 <br />TD1 <br />TD2 <br />TD3 <br />E-1 <br />E-2 <br />C <br />3A <br />42'-3" DISTANCE BETWEEN EXIT DOORS <br />63'-9" DISTANCE BETWEEN AREA SERVED <br />E-3 <br />E-4 <br />EXIT SIGN. REFER TO 1/AD1 <br />EXIT <br />PATH OF EGRESS <br />EXIT <br />-- <br />12" <br />EXIT TAG <br />No. OF OCCUPANTS EXITING <br />PROVIDED WIDTH OF <br />COMPONENT <br />OCCUPANCY <br />WITHOUTH <br />SPRINKLER <br />SYSTEM <br />(feet) <br />WITH <br />SPRINKLER <br />SYSTEM <br />(feet) <br />A,E,F-1,M,R,S-1 200 250 <br />I-1 NOT PERMITED 250 <br />H-2 <br />200 300 <br />H-3 <br />300 400 <br />H-4 <br />75 <br />H-5 <br />100 <br />I-2, I-3, I-4 <br />150 <br />B <br />175 <br />F-2, S-2, U <br />200 <br />H-1 <br />200 <br />NOT PERMITED <br />NOT PERMITED <br />NOT PERMITED <br />NOT PERMITED <br />NOT PERMITED <br />NOT PERMITED <br />JOB# <br />DATE <br />DRAWN <br />SCALE <br />Th <br />i <br />s <br /> <br />D <br />u <br />c <br />o <br />u <br />m <br />e <br />n <br />t <br /> <br />i <br />s <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />Y <br />N <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C. <br />, <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />be <br /> <br />r <br />e <br />p <br />o <br />r <br />d <br />u <br />c <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />c <br />o <br />n <br />s <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />Y <br />N <br />G <br /> <br />A <br />R <br />CH <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C <br />. <br />© <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />No. C-32798 <br />HC <br />F <br />RADSEN <br />E <br />S <br />TAT <br />LCAIOF <br />E <br />ILC <br />A <br />ORNI <br />TC <br />ITEYENNY NG <br />DATE <br />RENEWAL <br />03-31-25 <br />As indicated <br />A2.3 <br />FI <br />R <br />S <br />T <br /> <br />F <br />L <br />O <br />O <br />R <br />ME <br />A <br />N <br />S <br /> <br />O <br />F <br /> <br />E <br />G <br />R <br />E <br />S <br />S <br />YC23005 <br />AN <br />C <br />E <br />N <br />A <br />Y <br /> <br />C <br />O <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />JAN 2024 <br />T.N. <br />21 <br />0 <br /> <br />W <br />. <br /> <br />1 <br />9 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />FIRST FLOOR MEANS OF EGRESS 1SCALE: <br />1/4" = 1'-0" <br />TD1 -> E-2 (16'-6" + 36'-3") = 52'-9" < 300' <br />TD2 -> E-1 (8'-6" + 19'-4") = 27'-10" < 300' <br />E-2 (14'-3" + 36'-3") = 50'-6" < 300' <br />TD3 -> E-1 (25'-10" + 2'-4") = 28'-2) <300' <br />E-2 (31'-3") = 31'-3" < 300' <br />ALL NEW TRAVEL DISTANCES ARE LESS THAN 300' <br />SYMBOL LEGENDSMEANS OF EGRESS NOTES TABLE 1016.2: EXIT ACCESS TRAVEL DISTANCE DOORS DISTANCES <br />E-1 TO E-2 = 42'-3" <br />DIAGONAL AREA OF SERVICE = 63'-9" <br />THE MINIMUN SEPARATION BETWEEN REQUIRED EXIT ACCESS DOORS OR <br />EXITS SHALL BE EQUAL OR GREATER THAN 1/2 THE DIAGONAL OF THE <br />SPACE OR FLOOR IT SERVES IN NOT SPRINKLER BUILDINGS. PROPOSED <br />DISTANCES BETWEEN DOORS ARE GREATER THAN MINIMUM REQUIRED. <br />1. ALL MEANS OF EGRESS DOORS SHALL COMPLY WITH THE REQUIREMENTS OF <br />SECTION 1010.1. <br />THE FORCE FOR PUSHING OR PULLIING OPEN INTERIOR SWINGING EGRESS DOORS, <br />OTHER THAN FIRE DOORS, SHALL NOT EXCEED 5 POUNDS. FOR OTHER SWINGING <br />DOORS, AS WELL AS SLIDING AND FOLDING DOORS, THE DOOR LATCH SHALL <br />RELEASE WHEN SUBJECTED TO A 15-POUND FORCE. THE DOOR SHALL BE SET IN <br />MOTION WHEN SUBJECTED TO A 30-POUND FORCE. THE DOOR SHALL SWING TO A <br />FULL OPEN POSITIONWHEN SUBJECTED TO A 15-POUND FORCE. REVOLVING AND <br />SLIDING DOORS MAY BE USED IN OTHER THAN GROUP H OCCUPANCIES AS EGRESS <br />DOORS ONLY IF ALL OF THE REQUIREMENTS OF SECTION 1010.1.4.1 AND SECTION <br />1010.1.4.3, RESPECTIVELY, ARE MET. <br />2. SHOW CLEARLY THAT PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS <br />IN THIS BUILDING. SATISFY THE FOLLOWING: (1008.1.10) <br />A. THE ACTUATING PORTION OF THE RELEASING DEVISE SHALL EXTEND AT LEAST <br />ONE-HALF OF THE DOOR LEAF WIDTH. <br />B. THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15-POUND <br />C. PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE PANIC <br />HARDWARE IS REQUIRED, AND THE PAD SHALL NOT EXTEND ACROSS MORE THAN <br />ON HALF OF THE FLOOR WIDTH, MEASURED FROM THE LATCH SIDE. <br />D. PANIC HARDWARE IS LISTED IN ACCORDANCE WITH UL 305. <br />E. FIRE EXIT HARDWARE IS LISTED IN ACCORDANCE WITH UL 10C AND UL 305 <br />3. EXIT SIGN SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. INTERNALLY <br />ILLUMINATED EXIT SIGNS SHALL BE LISTED AND LABLED IN ACCORDANCE WITH UL 924 <br />AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTRUCTIONS AND CHAPTER 27. EXTERNALLY ILLMINATED EXITS SIGNS SHALL <br />COMPLY WITH THE GRAPHICS AND POWER SOURCE REQUIREMENTS IN SECTIONS <br />1013.6.1 AND 1011.6.3, RESPECTIVELY. WHEN THE FACE OF AN EXIT SIGN IS <br />ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT <br />LESS THAN 5-FOOTCANDLE (54LUX). (1013.3). <br />4. ANY TIME A BUILDING OR A PORTION OF A BUILDING IS OCCUPIED, THE MEANS OF <br />EGRESS SERVING THE OCCUPIED PORTION SHALL BE ILLUMINATED AT AN INTENSITY <br />OF NOT LESS THEN 1-FOOTCANDLE (11LUX) AT THE WALKING SURFACE LEVEL.. <br />5. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY <br />THE PERMISE'S ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, <br />ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM <br />FOR THE FOLLOWING AREAS: <br />A. AISLES AND UNENCLOSED EGRESS STAIWAYS IN ROOMS AND SPACES THAT <br />REQUIRE TWO OR MORE MEANS OF EGRESS. <br />B. CORRIDORS, INTERIOR EXIT STAIRWAYS AND RAMPS, AND EXIT PASSAGEWAYS IN <br />BUILDINGS REQUIRED TO HAVE TWO ORE MORE EXITS. <br />C. EXTERIOR EGRESS COMPONENTS AT OTHER THAT THE LEVEL OF EXIT DISCHARGE <br />UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRE TO HAVE <br />TWO OR MORE EXITS. <br />D. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1028.1, IN <br />BUILDINGS REQUIRE TO HAVE TWO OR MORE EXITS. <br />E. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1010.1..6, FOR EXIT DISCHRGE <br />DOORWAYS IN BUILDINGS REQUIRE TO HAVE TWO OR MORE EXITS. <br />6. THE EMERGENCY POWER SYSTEM SHALL ALSO BE CONNECTED TO AN EMERGENCY <br />ELECTRICAL SYSTEM WHICH IS TO PROVIDE CONTINUED ILLUMINATION FOR A <br />DURATION OF NOT LESS THAN 1-1/2 HR. IN CAE OF PRIMARY POWER LOSS. <br />CONTINUED ILLUMINATION IS TO BE PROVIDED FROM STORAGE BATTERIES, UNIT <br />EQUIPMENT, OR AN ON-SITE GENERATOR AND THE INSTALLATION OF THE <br />EMERGENCY POWER SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH CHAPTER <br />27. (1008.3.4). <br />7. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL <br />ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1-FOOTCABLE (11LUX) AND A <br />MINIMUM AT ANY POINT OF 0.1-FOOTCANDLE (1LUX) MEASURE ALING THE PATH OF <br />EGRESS AT FLOOR LEVEL. A MAXIMUM-TO-MINIMUM ILLUMINATIO UNIFORMITY RATIO <br />OF 40 TO 1 SHALL NOT BE EXCEEDED. (1008.3.5). <br />8. WHERE KEY-OPERATED LCKING DEVICES ARE USED, POST A SIGN ON OR ADJACENT <br />TO THE REQUIRED MAIN EXIT DOOR WITH 1-IN. LETTERING STATING: "THIS DOOR TO <br />REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." (1008.1.9.3). <br />9. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT <br />THE USE OF A KEY SPECIAL KNOWLEDGE, OR EFFORT. DOOR HANDLES, PULL, <br />LATCHES, LOCKS, AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34" TO 44" <br />ABOVE THE FINISHED FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE <br />BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT <br />REQUIRE MORE THAN ONE OPERATION. <br />Da <br />t <br />e <br /> <br />D <br />e <br />s <br />c <br />r <br />i <br />p <br />t <br />i <br />o <br />n <br />1 <br />0 <br />7 <br />/ <br />3 <br />1 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />2 <br />N <br />D <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />MAIN TRAVEL DISTANCES <br />1 <br />210 W 19th St <br />4/14/2025