My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2109 W Flora St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flora St
>
2109 W Flora St
>
2109 W Flora St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:01:55 PM
Creation date
6/1/2025 12:01:34 PM
Metadata
Fields
Template:
Plan
Permit Number
20178424
101113462
Full Address
2109 W Flora St
Document Relationships
101113462 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Flora St\2109 W Flora St
20178424 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Flora St\2109 W Flora St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:01 PM
Modified:
5/30/2025 2:57 PM
Text:
WWW.TITANSOLARPOWER.COM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />SERRANO <br />RESIDENCE <br />1 0.800 DC kW <br />9.930 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />21 09 <br />WEST FLORA ST <br />SANTA ANA, CA <br />92704 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 8521 0 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP1 47901 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN1 1 -30-22 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cDGIoUcDOL#JmDLO.com <br />323-698-4207 <br />SP: Green Life Home <br />Improvement <br />E1 <br />ELECTRICAL <br />LINE DIAGRAM <br />(N) SE1 0000H-US (240V) <br />SOLAREDGE HD INVERTER(N) 27 - Q.PEAK DUO BLK ML-G1 0+400 <br />HANWHA Q CELL MODULES WITH <br />P401 SOLAREDGE OPTIMIZERS (N) JB <br />NEMA 3R <br />... <br />DC1 DC2 <br />WITH INTEGRATED DC <br />DISCONNECT AND <br />AUTOMATIC RAPID <br />SHUTDOWN UPON AC GRID <br />DISCONNECT <br />DC <br />AC <br />G <br />AC1 <br />STRING B - 1 3 <br />WIRE/CONDUIT SCHEDULE <br />NOTE: TERMINATE LUGS AT 75°. WIRING/CONDUIT RACEWAY WILL BE MIN 7/8'' ABOVE THE ROOF <br />TAG DESCRIPTION CONDUCTOR TYPE/SIZE/QUANTITY CONDUIT <br />SIZE/TYPE <br />DC1 ARRAY TO JBOX <br />4 #1 0 AWG 2+ & 2- PV WIRE <br />FREE AIR <br />1 #6 AWG GND- BARE COPPER <br />DC2 JBOX TO INVERTER <br />4 #1 0 AWG 2+ & 2- THWN-2 <br />3/4" EMT <br />1 #8 AWG GND THWN-2 <br />AC1 INVERTER TO AC <br />DISCONNECT <br />3 #6 AWG L1 , L2 & N THWN-2 <br />3/4" EMT <br />1 #8 AWG GND THWN-2 <br />AC2 AC DISCONNECT TO <br />SUBPANEL "POI" <br />3 #6 AWG L1 , L2 & N THWN-2 <br />3/4" EMT <br />1 #8 AWG GND THWN-2 <br />AC3 (E) SUBPANEL TO <br />SUBPANEL "POI" <br />3 #2 AWG L1 , L2 & N THWN-2 <br />1 -1 /2" EMT <br />1 #8 AWG GND THWN-2 <br />G <br />N <br />(N) 60A AC <br />DISCONNECT <br />EATON DG222URB <br />60A, 2P, 240V, TYPE DG, <br />NON-FUSIBLE, NEMA 3R <br />AC2 <br />OPTIMIZER ISC CALCULATION <br />MAX# OF MODULES X MODULE <br />WATTAGE 5600 <br />= 1 4.00 AMPSNOMIMAL DC INPUT VOLTAGE OF <br />INVERTER 400 <br />(OPTIMIZER MAX OUTPUT CURRENT) <br />[CEC 690.8] <br />1 5 > 1 4.00 = OK <br />AMPS AMPS <br />1 1 .1 4A (MODULE ISC) /= 12.50A (OPTIMIZER ISC) = OK <br />OPTIMIZER VOC CALCULATION <br />LARGEST MODULE VOC FOR SINGLE-MODULE DC/DC CONVERTER CONFIGURATIONS (WITH <br />80V AFCI CAP) (CEC 690.7 DQ G 690.1 1 ) <br />MODULE VOC ____ X # OF MODULES PER CONVERTER ___X CF = V <br />MODULE VOC 45.30 TL IS GREATER THAN OR <br />EQUAL TO -5°C, C F 1 .1 2 <br />MODULES PER OPTIMIZER 1 .00 <br />VOLTS 50.74 <br />THE VALUE CALCULATED MUST BE LESS THAN <br />OPTIMIZERS MAX DC INPUT VOLTAGE 60V > 50.74 OK <br />OPTIMIZER SPECIFICATION <br />MAKE SOLAREDGE 401 <br />MAXIMUM INPUT DC POWER 430 <br />MAX INPUT VOLTAGE (VOC)60 V <br />SHORT CIRCUIT CURRENT (ISC)1 2.50 A <br />MAX OUTPUT CURRENT 1 5 A <br />MAX OUTPUT VOLTAGE 60 V <br />MODULE SPECIFICATION <br />MANUFACTURER HANHWA Q CELL <br />MODEL NO.Q.PEAK DUO BLK ML-G1 0+ 400 <br />PEAK POWER 400 W <br />RATED VOLTAGE (Vmp)37.1 3 V <br />RATED CURRENT (Imp)1 0.77 A <br />OPEN CIRCUIT VOLTAGE (Voc)45.30 V <br />SHORT CIRCUIT CURRENT (Isc)1 1 .1 4 A <br />INVERTER SPECIFICATION <br />INVERTER MAKE SOLAREDGE <br />INVERTER MODEL NO.SE1 0000H-US (240V) <br />MAX INPUT VOLTAGE 480 V <br />MAX INPUT CURRENT 27 A <br />NOMIMAL AC VOLTAGE 240 V <br />MAX AC CURRENT 42 A <br />INTERCONNECTION COMPLIANCE PER 705 CODE <br />MAX AC OUTPUT OF INVERTER WITH 1 25% <br />MAX AC OUTPUT <br />(AMPS) <br />TOTAL # <br />INVERTER <br />TOTAL MAX AC <br />OUTPUT 1 25%RESULT <br />(AMPS) <br />OCPD <br />SIZE <br />42.00 1 42.00 1 .25 52.50 60A <br />SERVICE PANEL CALCULATIONS WITH 1 20% <br />BUS RATING SIZE MUTIPLIER <br />(1 20%)RESULT MAIN <br />BREAKER <br />INVERTER AC <br />OUTPUT+1 25 <br />% <br />RESULT <br />200 1 .20 240 1 00 52.50 1 52.50 <br />240.00 >/= 1 52.50 = OK <br />NOTE: <br />705.1 2(B)(2)(3) BUSBARS <br />(B) WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER <br />ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT <br />CONTAINS LOADS, THE SUM OF 1 25 PERCENT OF THE POWER SOURCE(S) OUTPUT <br />CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING <br />THE BUSBAR SHALL NOT EXCEED 1 20 PERCENT OF THE AMPACITY OF THE <br />BUSBAR. THE BUSBAR SHALL BE SIZED FOR THE LOADS CONNECTED IN <br />ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL SHALL BE <br />APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED <br />BREAKER FROM THE POWER SOURCE THAT DISPLAYS THE FOLLOWING OR <br />EQUIVALENT WORDING: <br />WARNING: POWER SOURCE OUTPUT CONNECTION — DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE. <br />THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 1 1 0.21 (B). <br />THIS DISCONNECT WILL BE <br />THE RAPID SHUTDOWN <br />INITIATION DEVICE TO COMPLY <br />WITH CEC 690.1 2 (C) <br />STRING A - 1 4 M <br />(E <br />) <br />1 <br /> <br />0 <br />0 <br />A <br />MC <br />B <br />(E) EARTH <br />GROUND <br />GG <br />(N) 60A <br />EXISTING <br />1 00A MAIN SERVICE PANEL <br />240V, 1 P, 3W <br />PV OCPD <br />SCE METER# <br />22201 3-506053 <br />EXISTING <br />WIRES & <br />CONDUIT <br />NOTE: <br />1 ) PV BREAKER MUST BE INSTALLED <br />AT THE FARTHEST, OPPOSITE END <br />OF MAIN BREAKER <br />2) SOLAR GROUND TYING INTO THE <br />UFER GROUND POINT <br />AIC RATING: 1 0KNEW <br />200A SUBPANEL <br />EATON CH32B200R <br />"POINT OF CONNECTION" <br />G <br />N <br />(E)1 25A SUBPANEL <br />"LOCATED INSIDE <br />BEDROOM" <br />AC3 <br />(N)1 00A <br />(E) SUB <br />2109 W Flora St <br />01/27/23
The URL can be used to link to this page
Your browser does not support the video tag.