Laserfiche WebLink
PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />SERRANO <br />RESIDENCE <br />1 0.800 DC kW <br />9.930 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />21 09 <br />WEST FLORA ST <br />SANTA ANA, CA <br />92704 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 8521 0 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP1 47901 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN1 1 -30-22 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />caGIorcali@Jmail.com <br />323-698-4207 <br />SP: Green Life Home <br />Improvement <br />A0 <br />PROJECT INFO <br />VICINITY MAP <br />PV NOTES <br />VICINITY MAP <br />PROJECT SITE <br />OWNER:VELIA SERRANO <br />ADDRESS:21 09 WEST FLORA ST <br />SANTA ANA, CA 92704 <br />PHONE:(71 4) 643-0607 <br />EMAIL:velia.serrano@yahoo.com <br />AHJ:SANTA ANA CITY <br />APN:41 239705 <br />(ORANGE COUNTY) <br />AERIAL VIEW <br />1 0.800 DC kW SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT <br />21 09 WEST FLORA ST SANTA ANA, CA 92704 <br />SERRANO RESIDENCE <br />SHEET INDEX <br />A0 PROJECT INFO, VICINITY MAP, PV NOTES <br />A1 SITE PLAN <br />A2 MOUNTING ROOF PLAN <br />E1 SINGLE LINE DIAGRAM <br />E2 ELECTRICAL CALCULATIONS <br />E3 REQUIRED SIGNAGE <br />E4 - E4.1 MODULE DATA SHEET & CERTIFICATION <br />E5 - E5.1 INVERTER DATA SHEET & CERTIFICATION <br />E6 OPTIMIZER DATA SHEET <br />S1 STANCHION DATA SHEET <br />S2 RACKING DATA SHEET <br />S3 - S3.3 RACKING ENGINEERING <br />S4 RACKING GROUNDING <br />S5 RACKING CERTIFICATION <br />SOLAR PHOTOVOLTAIC SYSTEM NOTES <br />1 . ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE <br />LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS, CEC 1 1 0.2, 1 1 0.3, 690.4(B) AND 690.1 2(D). <br />2. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br />SWITCHES. <br />3. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />4. ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT PER <br />CEC 690.9. <br />5. DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY <br />ACCESSIBLE LOCATION NEAR THE EQUIPMENT, CEC 690.1 3, 690.1 5. <br />6. ENERGY STORAGE SYSTEMS TERMINALS LOCATED MORE THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM <br />CONNECTED EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE WITH CEC 706.7(E) AND LABELED PER <br />706.7(D). A SECOND DISCONNECTING MEANS LOCATED AT THE CONNECTED EQUIPMENT SHALL BE INSTALLED WHERE <br />THE DISCONNECTING MEANS AT THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT. <br />7. RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.1 2. <br />8. THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED <br />ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN <br />IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, <br />CEC 705.40. <br />9. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT <br />AND FOR THE APPLICATION. CEC31 0.1 0(D) AND 690.31 (C) THROUGH (F). <br />1 0. INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS, <br />CEC 690.31 (C). <br />1 1 . FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, <br />CEC 1 1 0.1 4. <br />1 2. ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION, CEC <br />690.31 (B). <br />1 3. ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC <br />200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH <br />INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.1 1 9 & 400.23. THE COLOR OF UNGROUNDED <br />CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 31 0.1 1 0(C). <br />1 4. MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 1 0 FEET, <br />CEC 705.31 . <br />1 5. CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY <br />DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.1 2(B). <br />1 6. DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE <br />SHEATHINGS, CEC 690.31 (G). <br />1 7. METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS <br />TO GROUND MUST BE BONDED IN ACCORDANCE WITH CEC 250.97. <br />1 8. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS, CEC <br />31 4.1 5 <br />1 9. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR <br />THAT ARE IDENTIFIED AND LISTED FOR SUCH USE, CEC 690.31 (H) & 1 1 0.1 4. <br />20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND <br />OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR <br />“NOT FOR CURRENT INTERRUPTING”, CEC 690.33(C) & (E)(2). <br />21 . EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM <br />PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.1 20(C). <br />22. THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, CEC <br />705.32. <br />23. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, <br />MUST BE PROTECTED, CEC 300.4. <br />24. PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL <br />UTILITY COMPANY. <br />25. FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD <br />WATER MUST BE PROVIDE, CEC 250.1 04. <br />26. GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH <br />SOIL, CEC 250.52(A)(5), 250.53(G). <br />27. MINIMUM 7/8’’ CLEARANCE FROM ROOF TO BOTTOM OF CONDUIT OR USE A TEMPERATURE ADDER OF 33 DEGREES C. <br />CEC 31 0.1 5(B)(3)(C) <br />28. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE <br />COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. <br />29. EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 1 2" FROM THE <br />PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE <br />MODULES, CPC 906.1 . <br />30. EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, <br />MUST BE EXTENDED 1 2" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1 (1 ) & CPC 509.6.1 (1 ). <br />31 . THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE <br />AT 1 0' O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, CEC <br />690.31 (G)(4). <br />32. PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV <br />CIRCUITS ONLY NO LOADS ARE TO BE CONNECTED. <br />33. WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, CEC 1 1 0.26. <br />34. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND <br />EXTENDING 3' ABOVE THE ROOF. <br />35. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY <br />INSPECTIONS. <br />36. LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN <br />WHITE ON A RED BACKGROUND. CEC 690.31 (G)(4) <br />37. IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). <br />38. WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO <br />INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT. <br />39. PANELS AND MODULES NOT TO BE INSTALLED ON ROOF BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. CRC <br />R324.6.2.2 <br />40. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 1 0-FEET AND A FIRE SEPARATION <br />DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES, CRC R324.7 & R302.1 . <br />41 . PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. <br />42. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. <br />43. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE <br />FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE <br />INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. <br />CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF <br />THE HOUSE. R31 4.1 , R31 5.1 <br />44. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. <br />APPLICABLE CODES <br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL <br />COMPLY WITH THE FOLLOWING APPLICABLE CODES <br />201 9 CA BUILDING CODES (CBC) <br />201 9 CA RESIDENTIAL CODES (CRC) <br />201 9 CA MECHANICAL CODES (CMC) <br />201 9 CA PLUMBING CODES (CPC) <br />201 9 CA FIRE CODES (CFC) <br />201 9 CA ELECTRICAL CODES (CEC) <br />201 9 CA ENERGY CODES (CEnC) <br />201 9 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) <br />PROJECT SCOPE <br />INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM <br />PV EQUIPMENT QTY MODEL NO AND MANUFACTURER <br />MODULES:27 Q.PEAK DUO BLK ML-G1 0 400 <br />HANWHA Q CELL MODULES <br />OPTIMIZERS:27 P401 SOLAREDGE OPTIMIZERS <br />INVERTER:1 SE10000H-US (240V) >SI1@ <br />SOLAREDGE HD INVERTER <br />SYSTEM SIZE:10.800 DC kW RATING <br />9.930 CEC AC RATING <br />ARRAY AREA:21.14 SQFT x 27 =570.66 SQFT <br />BUILDING INFO <br />OCCUPANCY:R3-SFD CONSTRUCTION TYPE:VB <br /># OF STORIES:1 BLDG AREA (SQFT):1584 <br />SPRINKLERS:NONE ROOF AREA (SQFT):3841 <br />ENGINEERING CRITERIA FOR RACKING <br />DESIGN WIND SPEED:110 MPH <br />WIND EXPOSURE CATEGORY:B <br />GROUND SNOW LOAD:O PSF <br />PROJECT SITE <br />MAIN SERVICE PANEL INFORMATION <br />EXISTING:YES UPGRADE:NO <br />BUS RATING:(E)100A MAIN BREAKER SIZE:(E)100A <br />PHASE:1PH MB POSITION:TOP <br /># OF WIRES:3 DERATE?:NO <br />VOLTAGE:240V DERATE SIZE:N/A <br />UTILITY FED:OH <br />METER#:222013-506053 <br />INTERCONNECTION THRU 200A SUBPANEL <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />12.12.2022 <br />The scope of the plans is for the <br />installation of the solar photovoltaic <br />system only and the approval is subject to <br />compliance with all applicable city and <br />state codes and regulations regarding <br />construction. The approval of the plans <br />does not constitute any certification of the <br />accuracy, completeness, or building <br />permit status of the existing buildings and <br />structures as shown. <br />Bldg# 101113462 <br />Elec# 20178424 <br />Issued 01/25/23 <br />2109 W Flora St <br />01/27/23