EXTERIOR WALL DETAIL 4 <br />EXISTING ROOF SHINGLE TO BE REMAIN <br />(E <br />) <br />1 <br />0 <br /> <br />7 <br />/ <br />8 <br />" <br />OV <br />E <br />R <br />H <br />A <br />N <br />G <br />(E)10 7/8" <br />OVERHANG <br />(E)10 7/8" <br />OVERHANG <br />” ’” <br />TYP. WATER CLOSET <br />1-HR FIRE RATED WALL 3 <br />EQ. EQ. <br />SIMPSON ST22 STRAP <br />@ 48" OCE.N. <br />ROOF RAFTER <br />W/ HANGERS <br />TO RIDGE <br />STUD WALL <br />5/8" TYPE X GYP. BD. <br />ADU MAIN HOUSE <br />5/8" TYPE X GYP. BD. <br />PROPOSED FLOOR PLAN 1 <br />A <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />Job No: <br />Drawn by: <br />Sheet: <br />A-1 <br />Date: <br />Scale:N.T.S. <br />DA <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />De <br />s <br />i <br />g <br />n <br />10 <br />4 <br />9 <br />2 <br /> <br />T <br />R <br />A <br />S <br />K <br /> <br />A <br />V <br />E <br />, <br /> <br /># <br />B <br />Ga <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />3 <br />Ph <br />o <br />n <br />e <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br />4 <br />1 <br />7 <br />- <br />1 <br />8 <br />3 <br />9 <br /> <br />- <br /> <br />( <br />6 <br />5 <br />7 <br />) <br />7 <br />2 <br />0 <br />- <br />8 <br />5 <br />5 <br />5 <br />Em <br />a <br />i <br />l <br />: <br /> <br />a <br />r <br />t <br />. <br />d <br />e <br />s <br />i <br />g <br />n <br />. <br />g <br />r <br />o <br />u <br />p <br />2 <br />0 <br />2 <br />2 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />J <br />A <br />D <br />U <br />22 <br />1 <br />7 <br /> <br />W <br />. <br /> <br />M <br />o <br />n <br />i <br />c <br />a <br /> <br />L <br />a <br />n <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />2 <br />. <br />PROPOSED FOOR PAN <br />ROOF PAN <br />AGING-IN-PLACE/FALL PREVENTION NOTES: <br />A. Reinforcement for Grab Bars. [R327.1.1] At least one bathroom on the entry level shall be provided with <br />reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least <br />one bathroom on the 2nd or 3rd floor of the dwelling shall comply. <br />1. Reinforcement shall be solid lumber or other construction materials approved by the enforcing agency. <br />2. Reinforcement shall not be less than 2 by 8 inch nominal lumber (1-1/2” x 7-1/4” actual dimension) or Other <br />construction material providing equal height and load capacity. Reinforcement shall be located between 32” and 39-1/4” <br />above the finished floor, flush with the wall framing. <br />3. Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back wall. <br />4. Shower reinforcement shall be continuous where wall framing is provided. <br />5. Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back <br />wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge <br />located no more than 6” above the bathtub rim. <br />6. Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom <br />shall have provisions for installation of floor-mounted, foldaway or similar alternate grab bar <br />reinforcements approved by the enforcing agency. <br />B. Documentation for Grab Bar Reinforcement. [R327.1.1.1] Information and/or drawings identifying the location of <br />grab bar reinforcement shall be placed in the operation & maintenance manual in accordance with the <br />California Green Building Standards Code, Ch. 4, Division 4.4. <br />C. Electrical Receptacle Outlet, Switch & Control Heights. [R327.1.2] Electrical receptacle outlets, switches and <br />controls (including controls for heating, ventilation and air conditioning) intended to be used by occupants shall <br />be located no more than 48” measured from the top of the outlet box and not less than 15” measured from the <br />bottom of the outlet box above the finish floor. <br />D. Doorbell Buttons. [R327.1.4] Doorbell buttons or controls, when installed, shall not exceed 48” above exterior floor or <br />landing, measured from the top of the doorbell button assembly. Where doorbell buttons integrated with other <br />features are required to be installed above 48” measured from the exterior floor or landing, a standard doorbell <br />button or control shall also be provided at a height not exceeding 48” above exterior floor or landing, measured <br />from the top of the doorbell button or control. <br />ROOF PLAN 2 <br />EXISTING ROOF SHINGLE <br />TO BE REMAIN <br />(E <br />) <br />1 <br />0 <br /> <br />7 <br />/ <br />8 <br />" <br />OV <br />E <br />R <br />H <br />A <br />N <br />G <br />(E)10 7/8" <br />OVERHANG <br />(E <br />) <br />1 <br />0 <br /> <br />7 <br />/ <br />8 <br />" <br />OV <br />E <br />R <br />H <br />A <br />N <br />G <br />(E)10 7/8" <br />OVERHANG <br />(E <br />) <br />1 <br />0 <br /> <br />7 <br />/ <br />8 <br />" <br />OV <br />E <br />R <br />H <br />A <br />N <br />G <br />(E)10 7/8" <br />OVERHANG <br />WHOLE BUILDING VENTILATION (ADU) <br />FLOOR AREA 474 S.F. <br />474/100 x 1 = 4.74 CFM <br />1 BEDROOM x 1 + 1 = 2 OCCUPANTS <br />2 x 7.5 = 15.0 CFM <br />CFM (FAN) = 4.74+15.0 = 19.74 CFM. USE 20-40 CFM FAN <br />USE THIS FAN MODEL: <br />*PANASONIC FV-04VE1 WHISPERCEILING OR EQUAL FAN IS <br />CONT. OPERATING WITH A SONAR RATING OF 1.0 MAX. <br />2 <br />A-1 <br />(E) BEDROOM <br />#1 <br />(E) BEDROOM <br />#2 <br />(E) BEDROOM <br />#3 <br />(E) BEDROOM <br />#4 <br />(E) Bth #1 <br />(E) Bth #2 <br />(E) PORCH <br />65 SF <br />EXISTING DWELING UNIT <br />1682 SF <br />(E) LIVING <br />(E) KITCHEN <br />(N) BEDROOM <br />ADU <br />(N) KITCHEN <br />ADU <br />(N) LIVING <br />ADU <br />(N) BTH. <br />5' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />5 <br />" <br />19 <br />' <br />- <br />5 <br />" <br />8'-2"3'-9"4'-3"8'-3" <br />24'-5" <br />3' <br />- <br />0 <br />" <br />2' <br />- <br />1 <br />1 <br />" <br />1'-0" <br />7' <br />- <br />6 <br />" <br />3'-0" <br />15min. <br />30"min <br />EXISTING WALL <br />NEW WALL <br />1HR FIRE RATED WALL <br />2 <br />A-1 <br />2 <br />A-1 <br />15min. <br />24 <br />" <br />m <br />i <br />n <br />. <br />KEY NOTES <br />2217 W Monica Ln, <br />#23/19/2025