LED RECESSED LIGHT <br />WALL MOUNTED LIGHT <br />VS <br />3-WAY SWITCH <br />SINGLE POLE SWITCH <br />SINGLE POLE SWITCH WITH DIMMER CONTROLS <br />D <br />S <br />3 <br />S <br />S SINGLE POLE SWITCH W VACANCY SENSOR <br />S <br />WALL MOUNTED SECURITY LIGHT <br />HOSE BIBB <br />FG <br />HB <br />FUEL GAS <br />AFCI 120 v SINGLE PHASE, 15 OR 20 AMP RECEPTACLES, WITH <br />ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE <br />125 V, SINGLE PHASE, 15 OR 20 AMP RECEPTACLES, WITH <br />GROUND FAULT CIRCUIT INTERRUPTERGFCI <br />COMBINATION OF CARBON MONOXIDE AND SMOKE <br />DETECTOR , HARD WIRED WITH BATTERY BACK UP & LOW <br />BATTERY SIGNAL <br />SD <br />SD-CO <br />SMOKE DETECTOR , HARD WIRED WITH BATTERY BACK UP & <br />LOW BATTERY SIGNAL <br />G.D. <br />GARBAGE DISPOSAL <br />EXHAUST FAN TO BE 50 CFM MIN AND TO HAVE HUMIDISTAT <br />CONTROL AND SWTCHED SEPARATE FROM LIGHTING <br />KITCHEN EXHAUST FAN 160 CFM (GAS RANGE) 280 CFM <br />(ELECTRIC RANGE) VENT TO OUTSIDE AIR. <br />IAQ FAN PER T24 <br />EXTERIOR LIGHTING TO BE ON A TIME/PHOTO <br />SENSOR <br />MINI SPLIT <br />A/C UNIT <br />(E) BEDROOM <br />#1 <br />(E) BEDROOM <br />#2 <br />(E) BEDROOM <br />#3 <br />(E) BEDROOM <br />#4 <br />(E) Bth #1 <br />(E) Bth #2 <br />(E) PORCH <br />65 SF <br />EXISTING DWELING UNIT <br />1682 SF <br />(E) LIVING <br />(E) KITCHEN <br />(N) BEDROOM <br />(N) KITCHEN <br />(N) LIVING <br />(N) BTH. <br />S <br />S <br />SSS <br />FG <br />G.D. <br />S <br />SS <br />SD <br />S <br />SD-CO <br />ATTIC <br />ACCESS <br />22X30 <br />EXISTING WALL <br />NEW WALL <br />1HR FIRE RATED WALL <br />EXISTING GARAGE <br />CONVERT TO ADU <br />474 SF <br />FG <br />A <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />Job No: <br />Drawn by: <br />Sheet: <br />A-2 <br />Date: <br />Scale:N.T.S. <br />DA <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />De <br />s <br />i <br />g <br />n <br />10 <br />4 <br />9 <br />2 <br /> <br />T <br />R <br />A <br />S <br />K <br /> <br />A <br />V <br />E <br />, <br /> <br /># <br />B <br />Ga <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />3 <br />Ph <br />o <br />n <br />e <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br />4 <br />1 <br />7 <br />- <br />1 <br />8 <br />3 <br />9 <br /> <br />- <br /> <br />( <br />6 <br />5 <br />7 <br />) <br />7 <br />2 <br />0 <br />- <br />8 <br />5 <br />5 <br />5 <br />Em <br />a <br />i <br />l <br />: <br /> <br />a <br />r <br />t <br />. <br />d <br />e <br />s <br />i <br />g <br />n <br />. <br />g <br />r <br />o <br />u <br />p <br />2 <br />0 <br />2 <br />2 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />J <br />A <br />D <br />U <br />22 <br />1 <br />7 <br /> <br />W <br />. <br /> <br />M <br />o <br />n <br />i <br />c <br />a <br /> <br />L <br />a <br />n <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />2 <br />. <br />PROPOSED EECTRICA PAN <br />EEVATION <br />PROPOSED ELECTRICAL PLAN 1 <br /> TOP DOOR/WINDOW <br />GROUND LEVEL <br /> FLOOR LEVEL <br /> TOP PLT. <br />(E)TOP OF STRUCTURE <br />2" <br />6' <br />- <br />8 <br />" <br />8' <br />- <br />0 <br />" <br />15 <br />' <br />- <br />0 <br /> <br />5 <br />/ <br />8 <br />" <br />MAIN HOUSE29'-2 5/8"ADU <br />EAST ELEVATION 4WEST ELEVATION 5 <br />2" <br />6' <br />- <br />8 <br />" <br />8' <br />- <br />0 <br />" <br />15 <br />' <br />- <br />0 <br /> <br />5 <br />/ <br />8 <br />" <br />MAIN HOUSE34'-0"ADU <br />SOUTH ELEVATION 3 <br />NORTH ELEVATION 2 <br /> TOP DOOR/WINDOW <br />GROUND LEVEL <br /> FLOOR LEVEL <br /> TOP PLT. <br />(E)TOP OF STRUCTURE <br />2" <br />6' <br />- <br />8 <br />" <br />8' <br />- <br />0 <br />" <br />15 <br />' <br />- <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />MAIN HOUSE30'-0"ADU <br />’’ <br />’ <br /> TOP DOOR/WINDOW <br />GROUND LEVEL <br /> FLOOR LEVEL <br /> TOP PLT. <br />(E)TOP OF STRUCTURE <br />8' <br />- <br />0 <br />" <br />15 <br />' <br />- <br />0 <br /> <br />5 <br />/ <br />8 <br />" <br />MAIN HOUSE54'-5" <br />2217 W Monica Ln, <br />#23/19/2025