Laserfiche WebLink
PREPARED BY J ASON HAYES <br />LIC.#947761 <br />SITE <br />PLAN <br />PV-01 <br />COMPANY <br />ADVANCED IMPROVEMENTS INC. <br />5031 <br /> E. ORANGETHORPE AVE UNIT G <br />71 <br />4-630-661 <br />1 <br />AERIAL VIEW MAP <br />SCALE: 1 INCH = 1 0 FOOT <br />ALL WORK SHALL COMPLY WITH 2022 CBC, CMC, CPC,CEC, CRC, <br />CFC ARTICLE 690, ALL CITY MUNICIPAL CODES, TITLE1 5, 24, CITY <br />AND STATE FIRE CODE AND ALL MANUFACTURER 'S LISTINGS <br />AND INSTALLATION INSTRUCTIONS. <br />ISSUE <br />1 <br />0.3.23 <br />DRAWN BY <br />JASON HAYES <br />CLIENT <br />NGUYEN,THOMAS <br />231 <br />4 W SAN LORENZO AVE <br />SANTA ANA, CA 92704 <br />PROJ <br />ECT <br />NGUYEN <br />PROJ <br />ECT NO. <br />2023.30051 <br />0 <br />1 0' 0" <br />TABLE OF CONTENTS <br />PAGE # DESCRIPTION <br />PV-01 SITE PLAN <br />PV-02 STRUCTURAL DETAILSOLAR SYSTEM UNDER 3 LB PER SQ FT <br />PROPERTY LINE <br />BACK YARD <br />R324.6.2 Setback at ridge: For photovoltaic arrays occupying <br />not more than 33 percent of the plan view total roof area , <br />not less than an 18-inch clear set back is required on <br />both sides of a horizontal ridge. For photovoltaic arrays <br />occupying more than 33 percent of the plan view total roof <br />area, not less than a 36-inch clear set back <br />is required on both sides of a horizontal ridge <br />C-10,20,36,39 <br />EXISTING MAIN ELECTRICAL SERVICE <br />ENPHASE COMBINER BOX WITH ENVOY NEXT TO MAIN SERVICE PANEL <br />1'-6" <br />ROOF AREA: 2454 SQ FT <br />SOLAR AREA: 608 <br />COVERAGE:<25% <br />FIRE SETBACK <br />N SYSTEM INFORMATION <br />ARRAY PITCH ORIENTATION <br />#1 22° 1 69° <br />SCOPE OF WORK: <br />1 . 8.7KW AC, 1 2KW DC MICRO INVERTER ROOF MOUNTED PV SYSTEM INSTALLED BY ADVANCED IMPROVEMENTS INC. LIC. # 947761 <br />2. (30) HANWHA Q-CELL 400W SOLAR MODULES AND (30) ENPHASE IQ8PLUS-72-2-US MICRO INVERTERS <br />3. ROOF TOP SOLAR SYSTEM MOUNTED USING IRONRIDGE SOLAR RACKING SYSTEM <br />4. WEIGHT DISTRIBUTION: 2.4 LBS/SQFT <br />5. TOTAL AREA OF ARRAYS: <608 SQ/FT <br />8.ROOF TYPE: COMP ROOF, 5/1 2 PITCH AND SINGLE STORY IN HEIGHT. <br />9. MICRO INVERTERS LOCATED UNDER EACH MODULE <br />1 0. CONNECT SOLAR SYSTEM TO MAIN ELECTRICAL DISTRIBUTION PANEL VIA CIRCUIT BREAKER. <br />1 1 . RUN CONDUIT ON ROOF TOP AND EXTERIOR WALL <br />1 2. OCCUPANCY: R3, CONSTRUCTION TYPE: VB, ROOF STRUCTURE: 2”X6” RAFTER AT 24” ON CENTER SPACING, 1 /2" PLYWOOD <br />SHEATHING (1 ) LAYER <br />1 3. WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE <br />MAINTAINED IN ACCORDANCE WITH CEC 1 1 0.26 <br />1 4. BUILDING INSPECTOR SHALL FIELD VERIFY THAT ALL SMOKE AND CO ALARMS ARE INSTALLED IN ACCORDANCE WITH CODE PRIOR TO <br />PROJ ECT FINAL APPROVAL PER CRC R31 4.1 , R31 5.1 <br />1 5. ALL CONDUIT PAINTED TO MATCH SURFACE <br />1 6. EXPOSURE: C, BASIC WIND SPEED: 1 1 0 MPH <br />1 7. APN: 41 2-262-30 <br />ROOF ACCESS <br />AND PATHWAYS <br />PER R324.6 <br />SOLAR ARRAYS <br />WILL MAINTAIN <br />2H2 FROM EDGES <br />ASCE 7-16 <br />46'-9" <br />46'-1"FRONT YARD <br />ROOF LADDER ACCESS PER CFC 605.11.1.1 CRC R324.7.1 <br />3/4" EMT HOME RUN <br />ALL SOLAR PANELS <br />PARALLEL TO ROOF <br />3" AIR GAP SEE PV-02 <br />FOR DETAIL <br />ROOF TOP J-BOX <br />Bldg# 101117407 <br />Elec# 20181463 <br />Issued 11/15/23 <br />The scope of the plans is for the installation of the solar photovoltaic <br />system only and the approval is subject to compliance with all <br />applicable city and state codes and regulations regarding construction. <br />The approval of the plans does not constitute any certification of the <br />accuracy, completeness, or building permit status of the existing <br />buildings and structures as shown. <br />2314 W San Lorenzo <br />Ave11/17/2023