Laserfiche WebLink
ROOFING <br />RAFTER <br />PV UICK BOLT <br />RAFTER <br />5 16"3-1 2" STAINLESS STEEL LAG BOLT MINIMUM <br />3" EMBEDDED AND SEALED WITH CHEMLINK M1 <br />5 16" 3" 304 STAINLESS FLASHING <br />SEALED WITH CHEMLINK M1 <br />SCALE: 1 INCH = 10 FOOT10' 0" <br />STRUCTURAL <br />PLAN <br />PV-0PREPARED BY JASON HAYES <br />LIC.#947761 <br />ILLUSTRATION IS FOR REFERENCE ONLY <br />SOLAR MODULE <br />CLAMP BOLT <br />SOLAR MODULE <br />CLAMP BOLT <br />3" 5" ROOF <br />CLEARANCE <br />SOLAR MODULESOLAR MODULE <br />UL LISTED 2703 SELF GROUNDING RACKING <br />(SEE PV-05) <br />NOTE: <br />IRONRIDGE RACKING <br />AND HARDWARE USED <br />STANDARD R10 RAIL <br />ALL FOOTINGS ARE <br />SPACED 4' ON CENTERS <br />WITH LESS THAN 20" <br />OVERHANG <br />T-BOLT MOUNTING <br />MID END CLAMPS MOUNT IN UPPER <br />CHANNEL <br /> <br />L BRACKET FOR MOUNTING IRON RIDGE RACKING <br />COMPANY <br />ADVANCED IMPROVEMENTS INC. <br />5031 E. ORANGETHORPE AVE UNIT G <br />ANAHEIM, CA 92 <br />07 <br />714-630-6611 <br />C-10,20,36,39 <br />48" <br />4 " <br />IRONRIDGE XR10 SPAN CHART <br />PER ASCE 7-16 <br />EXPOSURE: C <br />WIND SPEED: 110 MPH <br />EDGE AREA GROUP 1 <br />MAX SPAN PER CHART: 89 INCHES <br />ROOF ATTACHMENTS <br />ISSUE <br />10.3.23 <br />DRAWN BY <br />JASON HAYES <br />CLIENT <br />NGUYEN,THOMAS <br />2314 W SAN LORENZO AVE <br />SANTA ANA, CA 92704 <br />PROJECT <br />NGUYEN <br />PROJECT NO. <br />2023.300510 <br />46'-9" <br />46'-1" <br />4 <br />" <br />4 " <br />RIDGELINE <br />RAFTERS 24" ON CENTER <br />QUICKBOLT ATTACHMENT <br />SEE DETAIL TO RIGHT <br />IRONRIDGE RACKING SYSTEM <br />EAVE <br />2314 W San Lorenzo <br />Ave11/17/2023