MODULE C ARACTERISTICS <br />ELECTRICAL NOTES <br />1. GROUNDING WIRE WILL BE BONDED DIRECTLYAT THE GROUND BAR PER <br />690.47(C)(3) <br />2. ELECTRICAL SYSTEM GROUND WILL COMPLY WITH CEC 250 <br />3. MODULES WILL BE DIRCETLY CONNECTED INTO THE ENPHASE INVERTER <br />4. 690.6 A THE RE UIREMENTS OF ARTICLE 690 PERTAINING TO PHOTOVOLTAIC <br />SOURCE CIRCUITS SHALL NOT APPLY TO AC MODULES. THE PHOTOVOLTAIC <br />SOURCE CIRCUIT, CONDUCTORS AND INVERTERS SHALL BE CONSIDERED AS <br />INTERNAL WIRING OF AN AC MODULE. <br />5. THE ENPHASE MICRO INVERTER PROVIDES NECESSARY GROUND FAULT <br />PROTECTION AS RE UIRED BY CEC 690.5 GROUND FAULT PROTECTION. <br />6. THE PHOTOVOLTAIC SYSTEM HAS CONDUCTOR BONDED TO ALL RAILS, AND <br />MODULES AS RE UIRED BY CEC 690.41 SYSTEM GROUNDING <br />7. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703 <br />. INVERTERS CONFORM TO AND ARE LISTED UNDER UL 1741 AND COMPLY WITH <br />CEC 690.61 ANTI-ISLANDING PREVENTION <br />9. MODULE CONNECTORS COMPLY WITH CEC 690.33 <br />10. MODULE GROUNDING AND SIZE SHALL BE CEC 690.4 C AND 690.45 <br />11. ALL NON-CURRENT CARRYING METAL PART OF E UIPMENT SHALL BE <br />GROUNDED PER CEC 690.47 A <br />12. GROUNDING ELECTRODE SHALL BE SIZED AND INSTALLED TO CEC 690.47 <br />13. INVERTERS TO BE PLUGGED DIRECTLY INTO ENPHASE TRUNK CABLE, UPTO 13 <br />INVERTERS PER TRUNK CABLE. <br />14. TRUNK CABLE SHALL TERMINATE INTO WATER TIGHT PULL BO WITH STRAIN <br />RELIEF ADAPTER <br />15. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION. <br /> <br />SYSTEM C ARACTERISTICS <br />ENPHASE Q CABLE <br />BLACK-L1 <br />RED-L2 <br />SOLAR MODULES <br />BONDED WITH <br />IRONRIDGE GROUND LUG <br />CERTIFIED 2703 FIELD VERIFIABLRE <br />FACILITY/UFER GROUND <br />AC MICRO INVERTER SYSTEM <br />DC <br />AC <br />200A <br />M INCOMING <br />SERVICE <br />MAIN BREAKER <br />(NEW SOLAR READY) <br />MAIN DISTRIBUTION PANEL <br />TOP FED <br />240V-1PH 200A MAIN OCPD <br />WITH A 225A BUS <br />WARNING SIGNS: #2,3,4,5,7 <br />DC <br />AC <br />50A <br />10 MODULES <br />10 MODULES <br />BARE CU #6 GROUND USED <br />OUTSIDE OF CONDUIT PER 250.64 B <br />L S C <br />S 0.B IN ACCORDANCE WIT <br />0 .1 D <br />0A PV 00A MAIN 0A 0A 1 0 BUS <br />(1)-2 POLE 50 AMP <br />BREAKERS FOR SOLAR <br />DISCONNECTION <br />UL LISTED DYNOBOND <br />FOR MODULE TO MODULE <br />GROUNDING BETWEEN <br />ROWS <br />ENPHASE MICRO <br />INVERTER Q <br />CABLE UP TO 13 PER <br />BRANCH CIRCUIT <br />IQ8PLUS-72-2-US <br />ENPHASE <br />MICRO-INVERTERS <br />MODULES PLUG <br />INTO INVERTER <br />DIRECTLY <br />NOTE: SMOKE ALARMS AND CARBON MONO IDE DETECTORS <br />1 S : R314.3 CRC <br />. O <br />. <br />. I . <br />. I , . I <br /> <br /> , <br /> <br /> . <br />. A <br /> . <br />. A <br /> . <br />. A <br /> . <br />2 A <br /> <br /> - <br />, <br /> 1,000. L - <br /> <br /> <br /> <br /> . C <br /> . <br />T <br /> <br /> <br /> <br /> . R315 CRC <br />NOTE: T DC <br /> , <br /> IQ8 -72-2-US GEC. <br />SEE MANUFACTURE CUT SHEET <br />ENPHASE IQ COMBINER <br />X-IQ-AM1-240-3or4 <br />SEE CUT SHEET FOR DETAILS <br /> CONTAINS: <br />(3) 20A OCPD FOR SOLAR <br />(1) OCPD FOR ENVOY <br />COMBINING (2) L1 & (2) L2 <br />WARNING SIGN #6 <br />PREPARED BY JASON HAYES <br />LIC.#947761 <br />ELECTRICAL <br />PLAN <br />PV-0 <br />WIRING JUSTIFICATION <br />MA IMUM STRING SIZE: 13 1.21A=15.73A 125 = 19.6625A <br />#10 THWN-2 RATING IS 40A 77 HEAT 0 4-6 LOADS = 24.64A <br />WIRE CAP IS 24.64A 20A STRING SIZE <br />TOTAL NUMBER OF CONDUITS: 1 <br />CONDUIT TYPE: 3/4"EMT <br />EACH CONDUIT CONTAINS: <br />4-#10 AWG (CU) THWN-2 LOAD CARRYING CONDUCTORS <br />1-#10 AWG (CU) THWN-2 CONDUCTOR FOR EQUIPMENT GROUND <br />A <br />TOTAL NUMBER OF CONDUITS: 1 <br />CONDUIT TYPE: 3/4" LIQUID TIGHT <br />EACH CONDUIT CONTAINS: <br />2-#8 AWG (CU) THWN-2 LOAD CARRYING CONDUCTORS <br />1-#10 AWG (CU) THWN-2 FOR THE NEUTRAL(FOR ENVOY ONLY) <br />1-#10 AWG (CU) THWN-2 CONDUCTOR FOR GROUND <br />B <br />COMBINED SYSTEM SIZE: 30 1.21A=36.3A 125 = 45.375 <br />CIRCUIT SIZE:50A <br />#8 THWN-2 RATING IS 50A AT 75 <br />WIRE CAP IS 50A = 50A CIRCUIT SIZE <br /> <br />A B <br />SOLAR BREAKER <br />OPPOSITE END OF <br />FED BREAKER <br />COMPANY <br />ADVANCED IMPROVEMENTS INC. <br />5031 E. ORANGETHORPE AVE UNIT G <br />714-630-6611 <br />DC <br />AC10 MODULES CAUTION <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED <br />AS SHOWN: <br />SYSTEM LABELS AND WARNIN S <br />3 8" LETTER/PLACARD OR REFLECTIVE SIGNAGE: <br />WHITE LETTERING <br />RED BACK GROUND <br />ALL PLACARDS SHALL BE WEATHER RESISTANT <br />PERMANENTLY ETCHED PLACARDS. <br />HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE <br />CA FIRE CODE 605.11.1 MARKING <br />MARKING IS RE UIRED FOR DIRECT-CURRENT DC <br />CONDUIT ONLY <br />MAIN PANEL WILL BE LABLED <br />CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />DISCONNECT WILL BE LABELED <br />CAUTION: SOLAR CIRCUIT DISCONNECT <br />SIGN #1 FOR DC CONDUIT ONLY <br />WARNING: PHOTOVOLTAIC POWER SOURCE <br />WARNING <br />DUAL POWER SOURCES SECONG <br />SOURCE IS PHOTOVOLTAIC <br />SYSTEM <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />RATED A C OUTPUT OPERATING CURRENT: 36.3A <br />NOMINAL A C OPERATING VOLTAGE: 240V <br />SIGN #2 <br />SIGN #3 <br />SIGN #4 <br />SIGN #5 <br />SIGN #6 <br />SIGN #7 <br />WARNING <br />DUAL POWER SOURCES SECONG SOURCE <br />IS PHOTOVOLTAIC SYSTEM <br />RATED A C OUTPUT OPERATING CURRENT: 36.3A <br />NOMINAL A C OPERATING VOLTAGE: 240V <br />SOLAR PV SYSTEM E UIPPED WITH <br />RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZAR IN THE ARRAY <br />ISSUE <br />10.3.23 <br />DRAWN BY <br />JASON HAYES <br />CLIENT <br />NGUYEN,THOMAS <br />2314 W SAN LORENZO AVE <br />SANTA ANA, CA 92704 <br />PROJECT <br />NGUYEN <br />PROJECT NO. <br />2023.300510 <br />SERVICE POINT, <br />UTILITY METERING <br /> PV SYSTEM DISCONNECT <br />SOLAR PV <br />ARRAY ON ROOF WITH <br />MICRO INVERTERS <br />HANWHA .PEAK DUO BLK ML-G10 400 WATTS <br />OPEN CIRCUIT VOLTAGE VOC 45.3 VOLTS <br />MA POWER VOLTAGE VMP 37.13VOLTS <br />SHORT CIRCUIT CURRENT ISC 11.14 AMPS <br />MA POWER CURRENT IMP 10.77 AMPS <br />MODULE EFFICIENCY 20.4 <br />SERIES FUSE RATING 20 AMPS <br />UL LISTED 1703 UL <br />SYSTEM SIZE DC 12KW <br />NUMBER OF MODULES 30 <br />OUTPUT WITH INVERTER AC .7KW <br />MA OUTPUT VOLTAGE 264V <br />TYPICAL AC VOLTAGE 240V <br />OPERATING RANGE 211-264V <br />MA IMUM OUTPUT CURRENT PER 1.21 AMP <br />MA IMUM AC OUTPUT OVER CURRENT 20 AMPS <br />SYSTEM OPERATING CURRENT 36.3 AMPS <br />2314 W San Lorenzo <br />Ave11/17/2023