Laserfiche WebLink
CUSTOMER INFORMATION <br />NAME: KEVIN COTTAM <br />PROJECT ID AUR-73344 <br />DATE 3/14/2023 <br />CREATED BY SKV <br />SIGNATURE <br />CONTRACTOR INFORMATION <br />COORDINATES: 33.766260, <br />-117.845314 <br />ADDRESS: 2253 NORTH LYON <br />STREET, SANTA ANA, CA 92705 <br />AMERICAN SOLAR ADVANTAGE <br />ADDRESS: 13348 MONTE VISTA AVE, <br />CHINO, CA 91710 <br />LICENSE NUMBER: C-10 1009565 <br />2.400kW DC / 1.740kW AC / 2.163kW <br />CEC AC ROOF MOUNT PV SYSTEM <br />APN: 396-05-609 <br />PV-3.1 <br />STRUCTURAL DETAILS <br />DEAD LOAD CALCULATIONS <br />BOM QUANTITY LBS/UNIT TOTAL <br />WEIGHT (LBS) <br />MODULES 6 47.39 284.34 <br />MID-CLAMP 8 0.05 0.4 <br />END-CLAMP 8 0.05 0.4 <br />RAIL LENGTH 46 0.68 31.28 <br />SPLICE BAR 0 0.36 0 <br />TILE HOOK 12 1.95 23.4 <br />MICROINVERTER 6 2.38 14.28 <br />TOTAL WEIGHT OF THE SYSTEM (LBS)354.1 <br />TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 126.08 <br />WEIGHT PER SQ. FT.(LBS)2.80 <br />WEIGHT PER PENETRATION (LBS)29.50 <br />6" MAX <br />(N) IRONRIDGE XR100 RAIL <br />(N) SOLAR MODULE <br />(N) IRONRIDGE TILE HOOK <br />(N) STAINLESS STEEL 5/16" X 4" LAG <br />BOLT MIN. 2.5" EMBEDMENT <br />PILOT HOLE REQUIRED <br />(E) PLYWOOD ROOF DECKING <br />SCALE: NTS <br />(E) CONCRETE S-TILE ROOF <br />(E) 2 X 4 TOP CHORD @ 24" O.C. <br />(N) 3-COURSE MASTIC OR FELT-BIB <br />PRIMARY FLASHING <br />(E) PLYWOOD ROOF DECKING <br />(E) 2 X 4 TOP CHORD @ 24" O.C. <br />(N) ALUMINIUM SECONDARY FLASHING <br />This item has been digitally <br />signed and sealed on <br />03/16/2023 <br />2253 N Lyon St <br />06/06/23