Laserfiche WebLink
MSPAC <br />LC <br />CB <br />AC <br />CB <br />CUSTOMER INFORMATION <br />NAME: KEVIN COTTAM <br />PROJECT ID AUR-73344 <br />DATE 3/14/2023 <br />CREATED BY SKV <br />SIGNATURE <br />CONTRACTOR INFORMATION <br />COORDINATES: 33.766260, <br />-117.845314 <br />ADDRESS: 2253 NORTH LYON <br />STREET, SANTA ANA, CA 92705 <br />AMERICAN SOLAR ADVANTAGE <br />ADDRESS: 13348 MONTE VISTA AVE, <br />CHINO, CA 91710 <br />LICENSE NUMBER: C-10 1009565 <br />2.400kW DC / 1.740kW AC / 2.163kW <br />CEC AC ROOF MOUNT PV SYSTEM <br />APN: 396-05-609 <br />2253 NORTH LYON STREET, SANTA ANA, CA 92705 <br />PV-5 <br />PLACARDS <br />(N) PHOTOVOLTAIC <br />ARRAY <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS PHOTOVOLTAIC <br />SYSTEM ARE UNGROUNDED AND MAY BE <br />ENERGIZED <br />LABEL LOCATION <br />DC DISCONNECT, INVERTER <br />[To be used when inverter is ungrounded] <br /> WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION <br /> WARNING <br />LABEL LOCATION <br />AC DISCONNECT, <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 690.13 <br />SOLAR DISCONNECT <br />LABEL LOCATION <br />AC DISCONNECT, POINT OF INTERCONNECTION <br />PER CODE: CEC 690.13(B) <br />NOTES <br />1.PLACARDS SHALL MEET THE REQUIREMENTS <br />OF ARTICLES 690 AND 705, UNLESS <br />OTHERWISE SPECIFIED PER LOCAL AHJ <br />REQUIREMENTS. <br />2.PLACARDS SHALL MEET THE REQUIREMENTS <br />OF SECTION 110.21(B) AS REQUIRED AND <br />SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFTEY SIGNS AND LABELS. <br />3.PLACARDS SHALL BE PERMANENTLY AFFIXED <br />TO THE EQUIPMENT OR WIRING METHOD. <br />4.PLACARDS SHALL BE OF SUFFICIENT <br />DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED AND SHALL BE <br />HANDWRITTEN. <br />5.PLACARDS SHALL NOT COVER EXISTING <br />MANUFACTURER LABELS. <br />6.WARNING SIGNAGE TEXT SHALL BE MINIMUM <br />3/8" TALL. <br />LABEL LOCATION <br />SERVICE PANEL <br />PER CODE: CEC 705.10 <br />CAUTION:MULTIPLE SOURCES <br />OF POWER !! <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED <br />AS SHOWN! <br />! <br />LABEL LOCATION <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 705.12(B)(3-4) AND 690.59 <br /> WARNING <br />DUAL POWER SOURCE SECOND <br />SOURCE IS PHOTOVOLTAIC <br />SYSTEM <br />! <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVER-CURRENT DEVICE <br />LABEL LOCATION <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 705.12(B)(3)(2) <br />RATED AC OPERATING CURRENT <br />AC NOMINAL OPERATING VOLTAGE <br />27.26 <br />240 <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH <br />AMPS AC <br />VAC <br />LABEL LOCATION <br />AC DISCONNECT, POINT OF INTERCONNECTION <br />PER CODE: CEC 690.54 <br />LABEL LOCATION <br />AC DISCONNECT, COMBINER BOX <br />PER CODE: CEC 690.56(C)(2) <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />SYSTEM <br />LABEL LOCATION <br />AC DISCONNECT, <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 690.56(C) <br /> SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br /> "OFF" POSITION TO <br /> SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />LABEL LOCATION <br />CONDUIT, COMBINER BOX <br />PER CODE: CEC 690.31(D)(2) <br />WARNING:PHOTOVOLTAIC <br />POWER SOURCE <br />LABLABEL LOCATION <br />COMBINER BOX, JUNCTION BOX (ROOF), <br />AC DISCONNECT <br />WARNING-ELECTRIC SHOCK HAZARD <br />NO USER SERVICEABLE PARTS INSIDE <br />CONTACT AUTHORIZED SERVICE <br />PROVIDE FOR ASSISTANCE <br />GENERATION <br />THIS PANEL HAS A CUSTOMER OWNED <br />GENERATOR CONNECTED TO THE <br />LOAD SIDE OF THE MAIN BREAKER <br />GENERATION <br />THIS AC DISCONNECT ISOLATES THE <br />CUSTOMERS GENERATOR FROM THE <br />EDISON SYSTEM <br />LABEL LOCATION <br />MAIN SERVICE PANEL <br />LABEL LOCATION <br />AC DISCONNECT <br />SYSTEM UTILIZES MICROINVERTERS LOCATED UNDER EACH SOLAR MODULE <br />(E) PHOTOVOLTAIC <br />ARRAY <br />(N) AC DISCONNECT-2 <br />(E) UTILITY METER WITH <br />MAIN SERVICE PANEL <br />(N) LOAD CENTER <br />(N) ENPHASE IQ COMBINER 4 (E) ENPHASE IQ COMBINER 3 <br />(E) AC DISCONNECT-1 <br />This item has been digitally <br />signed and sealed on <br />03/16/2023 <br />2253 N Lyon St <br />06/06/23