My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2404 E Buffalo Ave - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Buffalo Ave
>
2404 E Buffalo Ave
>
2404 E Buffalo Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:04:31 PM
Creation date
6/1/2025 12:04:16 PM
Metadata
Fields
Template:
Plan
Permit Number
20178656
101113770
Full Address
2404 E Buffalo Ave
Document Relationships
101113770 - Permit
(Permit - Plan)
Path:
\Building\Permits\B\Buffalo Ave\2404 E Buffalo Ave
20178656 - Permit
(Permit - Plan)
Path:
\Building\Permits\B\Buffalo Ave\2404 E Buffalo Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
IQ ENVOY <br />ON <br />OFF <br />G <br />15A <br />(2) #12 ENPHASE Q-CABLE <br />(1) #6 AWG BARE GROUND <br />30' AC WIRE RUN <br />(4) #10 THWN-2 <br />(1) #8 THWN-2 E.G.C <br />3/4" EMT 10' AC WIRE RUN <br />(3) #10 THWN-2 <br />(1) #8 THWN-2 E.G.C <br />3/4" EMT <br />10' AC WIRE RUN <br />(3) #10 THWN-2 <br />(1) #8 THWN-2 E.G.C <br />3/4" EMT <br />15A <br />15A <br />(2) #12 ENPHASE Q-CABLE <br />(1) #6 AWG BARE GROUND <br />(N) (8) Q.PEAK DUO BLK ML-G10+400 <br />(N) (8) ENPHASE IQ7PLUS-72-2-US 240V <br />(N)(1) ENPHASE IQ COMBINER 4, <br />X-IQ-AM1-240-4 64A/240V <br />CONTINUOUS, PROTECTION MAX <br />80A BREAKER ON SOLAR OUPUT; <br />WITH 10KAIC CIRCUIT BREAKERS <br />(N) JUNCTION BOX <br />600V, NEM 3R <br />UL LISTED <br />(N) (8) Q.PEAK DUO BLK ML-G10+400 <br />(N) (8) ENPHASE IQ7PLUS-72-2-US 240V <br />M <br />(N) 200 MAIN SERVICE <br />METER/PANEL 120/240VAC, 1-PHASE, <br />3-WIRE, 10KAIC & 10KSCIR RATING, MSP <br />SUITABLE FOR USE WITH 60°C/75°C Cu/Al <br />WIRE - METER #: 222013-507459 <br />N <br />G <br />30A <br />200 A(N)(1) LOCKABLE BLADE TYPE <br />NON-FUSIBLE AC DISCONNECT <br />NEM 3R 60A-2P 120/240VAC <br />EATON DG222URB <br />RI <br />D <br /> <br />2 <br />2 <br />4 <br />2 <br />2 <br /> <br />- <br /> <br />H <br />E <br />A <br />T <br />H <br />E <br />R <br /> <br />R <br />U <br />H <br />L <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />24 <br />0 <br />4 <br /> <br />E <br /> <br />B <br />U <br />F <br />F <br />A <br />L <br />O <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />AP <br />N <br /> <br />3 <br />9 <br />6 <br />2 <br />8 <br />2 <br />1 <br />3 <br />5205 AVENIDA ENCINAS STE <br />D, CARLSBAD, CA 92008 <br />LICENSE: # 1063901 <br />LICENSE TYPE: A/B <br />LICENSE: # 1063901 <br />LICENSE TYPE: C-10 <br />PV-4 <br />SINGLE LINE <br />DIAGRAM <br />NOTES: <br />1- ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND <br />ELECTRICALLYCONTINUOUS (NEC 250.90, 250.96). <br />2- GROUNDING BUSHINGS ARE REQUIRED AROUND PREPUNCHED CONCENTRIC <br />KNOCKOUTS ON THE DC SIDE OF THE SYSTEM (NEC 250.97) <br />3- THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR <br />SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. (NEC 250.64) <br />4- THE EQUIPMENT GROUNDING CONDUCTOR MAY BE USED AS A GROUNDING <br />ELECTRODE CONDUCTOR. (NEC 250.121 EXCEPTION, INSTALLED PER 250.6(A), II, III, <br />VI.) <br />5- INSTALLER TO IDENTIFY THE EXISTING GROUNDING ELECTRODE TYPE (I.E. <br />DRIVEN ROD, UFER, WATER PIPE, OR COMBINATION OF SOME OR ALL OF THE <br />PREVIOUSLY MENTIONED). IN EXISTING ELECTRICAL SYSTEMS THAT USE ONLY A <br />WATER PIPING GROUNDING ELECTRODE SYSTEM, AN ADDITIONAL GROUNDING <br />ELECTRODE (I.E DRIVEN ROD) SHALL BE PROVIDED. (NEC 250.50) <br />-PER NEC 250.53(2), A SINGLE ROD, PIPE OR PLATE ELECTRODE SHALL BE <br />SUPPLEMENTED BY AN ADDITIONAL ELECTRODE OF TYPE SPECIFIED IN 250.52(A)(2) <br />THROUGH (A)(8) SPACED NO LESS THAN 6FT APART. EXCEPTION, IF A SINGLE ROD, <br />PIPE OR PLATE GROUNDING ELECTRODE HAS A RESISTANCE TO EARTH OF 25 <br />OHMS OR LESS, THE SUPPLEMENTAL ELECTRODE SHALL NOT BE REQUIRED. <br />-#4 AWG CU TO UNDERGROUND METAL WATER PIPE THAT IS A MINIMUM 10 FOOT <br />BURIAL IN PIPE LENGTH. CONNECT GROUNDING ELECTRODE CONDUCTOR WITHIN <br />FIVE FEET OF WHERE IT ENTERS BUILDING. 250.52(A)(1), 250.68(C). <br />-ADDITIONAL #4 AWG CONNECTION TO UFER IF AVAILABLE PER 250.66. IF UFER NOT <br />AVAILABLE THEN TWO #6 AWG CU CONNECTIONS TO GROUND RODS SEPARATED <br />BY AT LEAST 6 FT IS NEEDED 250.33. <br />310.15(B)(3)(C) RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS. <br />WHERE RACEWAYS OR CABLES ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE <br />ROOFTOPS, RACEWAYS OR CABLES SHALL BE INSTALLED A MINIMUM DISTANCE <br />ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR CABLE OF 23 MM (7∕8 IN.). <br />WHERE THE DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY IS <br />LESS THAN 23 MM (7∕8 IN.), A TEMPERATURE ADDER OF 33°C (60°F) SHALL BE ADDED <br />TO THE OUTDOOR TEMPERATURE TO DETERMINE THE APPLICABLE AMBIENT <br />TEMPERATURE FOR APPLICATION OF THE CORRECTION FACTORS IN TABLE <br />310.15(B)(2)(A) OR TABLE 310.15(B)(2)(B). <br />ENPHASE Q CABLE TO BE ATTACHED TO RAIL MIN. 3-1/2" ABOVE ROOF SURFACE <br />CONDUIT HEIGHT = 7/8" ABOVE ROOF SURFACE <br />WHEN A BACKFEED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, <br />BREAKER SHALL NOT READ LINE AND LOAD. CEC 690-13(F)(2) <br />CIRCUIT CALCULATION <br />NUMBER OF <br />PANELS (MAX 13) <br />CONTINUOUS <br />OUTPUT (A)CONTINUOUS RESULT (A) <br />CIRCUIT 1 8 19.36 1.25 193.60 <br />CIRCUIT 2 8 19.36 1.25 193.60 <br />CIRCUIT 3 0 19.36 1.25 0.00 <br />CIRCUIT 4 0 19.36 1.25 0.00 <br />TOTAL 387.20 <br />EXISTING 100A MAIN SERVICE PANEL TO <br />BE UPGRADED TO NEW 200 PANEL <br />PV SOLAR BREAKER TO BE <br />MOUNTED ON THE OPPOSITE <br />END OF THE BUSBAR FARTHEST <br />FROM THE MAIN BREAKER OR <br />INPUT FEEDER, AND NOT TO BE <br />AT BOTH ENDS IF IT IS A <br />CENTER-FED PANELBOARD. <br />705.12 (B)(2)(3)(b) or (d) <br />SOLAR PV CIRCUIT BREAKER AIC RATING = 10kA <br />MAIN SERVICE BUS RATING PER NEC 705.12(B)(2)(3)(b) <br />BUS <br />RATING <br />MAIN <br />BREAKER BACKFEED <br />200 x 120% - 200 = 40 <br />2404 E Buffalo Ave <br />02/15/23
The URL can be used to link to this page
Your browser does not support the video tag.