Laserfiche WebLink
RI <br />D <br /> <br />2 <br />2 <br />4 <br />2 <br />2 <br /> <br />- <br /> <br />H <br />E <br />A <br />T <br />H <br />E <br />R <br /> <br />R <br />U <br />H <br />L <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />24 <br />0 <br />4 <br /> <br />E <br /> <br />B <br />U <br />F <br />F <br />A <br />L <br />O <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />AP <br />N <br /> <br />3 <br />9 <br />6 <br />2 <br />8 <br />2 <br />1 <br />3 <br />5205 AVENIDA ENCINAS STE <br />D, CARLSBAD, CA 92008 <br />LICENSE: # 1063901 <br />LICENSE TYPE: A/B <br />LICENSE: # 1063901 <br />LICENSE TYPE: C-10 <br />PV-5 <br />WARNING LABEL <br />SIGNAGE <br />CAUTION <br /> POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED <br />AS SHOWN: <br />NEC 705.10 - ON MAIN SERVICE PANEL: <br />PV SYSTEM DISCONNECT <br />PV SOLAR BREAKER <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />DEVICE <br />NEC 705.12(B)(2)(3)(c) - BY BREAKER AT <br />DISTRIBUTION EQUIPMENT: <br /> WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />NEC 690.13(B) - AT COMBINER PANEL, <br />AC DISCONNECT, POINT OF <br />INTERCONNECTION <br />RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br />NEC 690.56 - ON RAPID SHUTDOWN DISCONNECT: <br />(690.56(C) RED WITH WHITE LETTERING) <br />NEC 690.13 (B) - AC/DC DISCONNECT <br />NEC 690.54 - ON AC DISCONNECT: <br />ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF <br />CALIFORNIA ELECTRICAL CODE WILL BE INSTALLED AS REQUIRED. <br />ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR <br />PLASTIC, ENGRAVED, OR MACHINE PRINTED LETTERS IN A <br />CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE <br />ATTACHED BY APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT <br />SHALL BE UV RESISTANT. <br />PHOTOVOLTAIC DC CONDUCTORS SHALL BE LABELED, "WARNING <br />PHOTOVOLTAIC DC POWER SOURCE" OR EQUIVALENT EVERY 10 FT <br />AND KEPT MINIMUM 18" BELOW THE ROOF SURFACE. PV DC CIRCUIT <br />LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM <br />THAT IS SEPARTED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, <br />OR FLOORS. PV DC LABELS SHALL BE REFLECTIVE, SUITABLE FOR <br />SURROUNDING ENVIRONMENT, AND WHITE LETTERING ON A RED <br />BACKGROUND. [690.31(G)] <br />EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE <br />FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE <br />GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) <br />REGARDLESS OF VOLTAGE. <br />EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED <br />CONNECTION POINT IDENTIFIED ON THE MODULE AND THE <br />MANUFACTURER'S INSTRUCTIONS. <br />IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE <br />VERIFIED OR IS ONLY <br />METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY <br />TO INSTALL A <br />SUPPLEMENTAL GROUNDING ELECTRODE. <br />EQUIPMENT COMPLIES WITH RAPID SHUTDOWN REQUIREMENTS. <br />[690.12] PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING <br />COLOR TO THE PLAQUE. <br />PLAQUES SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH <br />MUNICIPALITY APPROVED METHOD. <br />24 <br />0 <br />4 <br /> <br />E <br /> <br />B <br />U <br />F <br />F <br />A <br />L <br />O <br /> <br />A <br />V <br />E <br /> WARNING <br />DUAL POWER SOURCE <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />NEC 705.12(B)(3-4), NEC 690.59 - MAIN <br />SERVICE DISCONNECT <br />WARNING <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />NEC 110.27(C), OSHA 1910.145(f)(7) - <br />COMBINER PANEL(S), MAIN SERVICE <br />DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH <br />RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />NEC 690.56 - WITHIN 3FT OF ALL DISCONNECTS: <br />(690.56(C)(1)(a) YELLOW WITH BLACK LETTERING) <br />AC PHOTOVOLTAIC DISCONNECT <br />RATED AC OUTPUT CURRENT (A):309.7 <br />6 <br />NOMINAL OPERATING AC VOLTAGE: 240V <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE <br />705.12(B)(2)(3)(b) - MAIN SERVICE <br />DISCONNECT, POINT OF <br />INTERCONNECTION <br />DO NOT DISCONNECT UNDER LOAD <br />NEC 690.15 (C), NEC 690.33(E)(2) - MAIN <br />SERVICE DISCONNECT <br />WARNING: PHOTOVOLTAIC POWER <br />SOURCE <br />NEC 690.31(G)(3-4) - EMT, CONDUIT RACEWAY <br />SERVICE POINT & <br />UTILITY METER <br />222013-507459 <br />PV SYSTEM <br />DISCONNECT <br />FOR UTILITY <br />OPERATION <br />PV DISCONNECT <br />ENPHASE COMBINER <br />PV ARRAY <br />ON ROOF <br />2404 E Buffalo Ave <br />02/15/23