Laserfiche WebLink
G <br />EXISTING GROUNDING <br />ELECTRODE SYSTEM <br />N <br />(E) 200A-2P <br />(N) 40A-2P <br />(E) 200A MAIN SERVICE PANEL <br />(E) 200A / 2P MAIN BREAKER <br />(E) LOADS <br />4 <br />INTERCONNECTION NOTES: <br />1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [CEC 705.12], AND [CEC 690.64]. <br />3. GROUND FAULT PROTECTION IN ACCORDANCE WITH [CEC 215.9], [CEC 230.95] AND [CEC 690.5] <br />4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. <br />5. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. <br />DISCONNECT NOTES <br />1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE <br />CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) <br />2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH <br />N <br />G <br />BRANCH CIRCUIT (1): <br />12 MODULES <br />NEMA 3 <br />JUNCTION BOX <br />BRANCH CIRCUIT (2): <br />12 MODULES <br />DC <br />AC <br />DC <br />AC <br />DC <br />AC <br />DC <br />AC <br />DC <br />AC <br />DC <br />AC <br />1 2 <br />1 2 3 <br />JUNCTION <br />BOX <br />JUNCTION <br />BOX <br />ENPHASE IQ8PLUS-72-2-US <br />MICROINVERTER(S) <br />(N) ENVOY <br />BREAKER <br />THIS BREAKER MAY BE 10A OR 15A <br />AS PER MANUFACTURER, THIS <br />BREAKER ENERGIZES THE ENVOY <br />INSTALLED BY MANUFACTURER <br />(N) 125A IQ COMBINER <br />NEW <br />(2) 20A-2P <br />4 <br />PV AC DISCONNECT <br />VISIBLE, LOCKABLE, <br />LABELED, OPEN <br />60A, 240V, 2-POLE <br />M <br />(E) UTILITY METER <br />COMPLETE SOLAR <br />3000 EXECUTIVE PKWY,STE 504 <br />SAN RAMON, CA 94583 <br />LICENSE TYPE C10 <br />LICENSE # 961988 <br />PHONE # (877) 299-4943 <br />DESIGNED BY: BRAD NEWMAN <br />SITE INFORMATION: <br />MAX CONTINUOUS AC SYSTEM SIZE: <br />6.96 kW <br />DC SYSTEM SIZE: 8.4 kW <br />(24) LONGI LR4-60HPB-350M <br />MODULES <br />(24) ENPHASE IQ8PLUS-72-2-US <br />INVERTER(S) <br />MOUNTING EQUIPMENT: <br />UNIRAC SM & UNIRAC - FLASHLOC <br />COMP <br />LOPEZ <br />ROBERTO LOPEZ PROJECT <br />2826 RIDGEWOOD ST <br />SANTA ANA, CA 92705 <br />LAT , LONG: 33.7761031, <br />-117.8412164 <br />LINE DIAGRAM <br />VISIBLE, LOCKABLE, <br />LABELED AC DISCONNECT <br />LOCATED WITHIN 10' <br />OF THE UTILITY METER <br />CALCULATIONS: <br />PER CEC 690.80, "WHERE A SINGLE OVERCURRENT DEVICE IS USED TO PROTECT A SET OF TWO OR <br />MORE PARALLEL-CONNECTED MODULE CIRCUITS, THE AMPACITY OF EACH OF THE MODULE <br />INTERCONNECTION CONDUCTORS SHALL NOT BE LESS THAN THE SUM OF THE RATING OF THE SINGLE <br />FUSE PLUS 125 PERCENT OF THE SHORT-CIRCUIT CURRENT FORM THE OTHER PARALLEL-CONNECTED <br />MODULES." <br />MODULE COUNT(24) * MICROINVERTER MAX OUTPUT CURRENT(1.21) * (1.25) = 36.30A < 40A <br />'$7(2FWREHU <br />Wire Tag <br /># <br />1 (1) 12 - 2 TC - ER, THWN-2, COPPER,(OR CODE APPROVED EQUIVALENT), (1) 6 AWG BARE, COPPER (GROUND) <br />2 (1) 10 AWG THWN - 2, OR THHN, COPPER - (POSITIVE),(1) 10 AWG THWN - 2, OR THHN, COPPER - (NEGATIVE),(1) 10 AWG THHN/THWN, COPPER - (GROUND),(1) 3/4"EMT <br />3 (2)10 AWG THHN/THWN-2,COPPER -(L1), (2)10 AWG THHN/THWN-2,COPPER -(L2), (1) 10 AWG THHN/THWN-2 (GROUND), CONDUIT: 3/4" EMT <br />4 (1) 8 AWG THWN-2 COPPER - (L1), (1) 8 AWG THWN-2 COPPER - (L2), (1) 8 AWG THWN-2 COPPER - (NEUTRAL), (1) 10 AWG THWN-2 COPPER - (GROUND),(1) CONDUIT: 3/4" EMT <br />String1:12 <br />String2:12 <br />String3:0 <br />String4:0 <br />String5:0 <br />String6:0 <br />Scope of Work: <br />(24) LONGI LR4-60HPB-350M <br />(24) ENPHASE IQ8PLUS-72-2-US INVERTER(S) <br />PV-6.0 <br />COMPLETE <br />SOLAR <br />2826 N Ridgewood St- <br />101118523 & 201823013/11/2024