COMPLETE SOLAR <br />3000 EXECUTIVE PKWY,STE 504 <br />SAN RAMON, CA 94583 <br />LICENSE TYPE C10 <br />LICENSE # 961988 <br />PHONE # (877) 299-4943 <br />DESIGNED BY: BRAD NEWMAN <br />SITE INFORMATION: <br />MAX CONTINUOUS AC SYSTEM SIZE: <br />6.96 kW <br />DC SYSTEM SIZE: 8.4 kW <br />(24) LONGI LR4-60HPB-350M <br />MODULES <br />(24) ENPHASE IQ8PLUS-72-2-US <br />INVERTER(S) <br />MOUNTING EQUIPMENT: <br />UNIRAC SM & UNIRAC - FLASHLOC <br />COMP <br />LOPEZ <br />ROBERTO LOPEZ PROJECT <br />2826 RIDGEWOOD ST <br />SANTA ANA, CA 92705 <br />LAT , LONG: 33.7761031, <br />-117.8412164 <br />LABELS <br />DATE:October 24, 2022 <br />THE EQUIPMENT FED BY MULTIPLE SOURCES. <br />TOTAL RATING OF ALL OVERCURRENT DEVICES, <br />EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, <br />SHALL NOT EXCEED AMPACITY OF BUSBAR <br />LABELING NOTES: <br />1. LABELING REQUIREMENTS BASED ON THE 2020 CALIFORNIA ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. <br />2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [CEC 110.21] <br />4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] <br />PERMANENT WARNING LABELS SHALL BE APPLIED TO <br />DISTRIBUTION EQUIPMENT <br />FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND <br />CONDUCTORS LEAVING THE ARRAY: <br />THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH <br />RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED <br />CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN BLACK <br />ON YELLOW BACKGROUND, AND THE REMAINING <br />CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM <br />HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. <br />[CEC 690.56(C)(1)(A)] <br />A PERMANENT WARNING LABEL SHALL BE APPLIED TO <br />THE DISTRIBUTION EQUIPMENT ADJACENT TO THE <br />BACK-FED BREAKER FROM THE INVERTER. <br />[CEC 705.12(D)(2)(3)(b)] <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL <br />LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH <br />THAT INCLUDES THIS WORDING. THE LABEL SHALL BE <br />REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND <br />HAVING A MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED <br />BACKGROUND.[CEC 690.56(C)(2)] <br />AT POINT OF INTERCONNECTION, MARKED AT <br />DISCONNECTING MEANS [CEC 690.54] <br />SECOND SOURCE IS PHTOVOLTAIC SYSTEM <br />AT POINT OF INTERCONNECTION. <br />[CEC 705.12(D)(3)] <br />MAXIMUM AC OPERATING CURRENT: <br />PHOTOVOLTAIC AT EACH DC DISCONNECTING MEANS <br />[CEC 690.13(B)] <br />AT EACH AC DISCONNECTING <br />MEANS <br />[CEC 690.13(B)] <br />AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER <br />WIRING METHODS; SPACED AT MAXIMUM 10FT <br />SECTION OR WHERE SEPARATED BY ENCLOSURES, <br />WALLS, PARTITIONS, CEILINGS, OR FLOORS <br /> [CEC 690.31(G)(3)] <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />PHOTOVOLTAIC AC DISCONNECT <br />DUAL POWER SOURCE <br />NOMINAL OPERATING AC VOLTAGE: <br />DC DISCONNECT <br />EACH PV SYSTEM DISCONNECTING MEANS SHALL <br />PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR <br />CLOSED (ON) POSITION AND BE PERMANENTLY <br />MARKED [CEC. 690.13(B)] <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />AT BUILDING OR STRUCTURE MAIN <br />DISCONNECTING MEANS. [CEC 690.12(E), CEC <br />690.15]WARNING <br />ELECTRICAL SHOCK HAZARD <br />DO NO TOUCH TERMINALS <br />TERMINALS ON BOTH LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION <br />WARNING! <br /> INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />WARNING! <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />! <br />WARNING! <br />29.04 <br />240 <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />!! <br />PV-7.0 <br />COMPLETE <br />SOLAR <br />2826 N Ridgewood St- <br />101118523 & 201823013/11/2024