My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3002 W Cubbon St - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cubbon St
>
3002 W Cubbon St
>
3002 W Cubbon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:06:31 PM
Creation date
6/1/2025 12:06:25 PM
Metadata
Fields
Template:
Plan
Permit Number
20181281
101117158
Full Address
3002 W Cubbon St
Document Relationships
101117158 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cubbon St\3002 W Cubbon St
20181281 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cubbon St\3002 W Cubbon St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM <br />NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROMHIS SITE INSPECTION. <br />1 Project Information:PV SOLAR ARRAY: YAM RESIDENCELatitude33.7352°deg N 3002 W. CUBBON STREET, SANTA ANA, CA 92705Longitude-117.910°deg WWind Speed 110 mph 95 mph (ASCE 7-22)Wind Exposure CSite Class DSeismic Design Category D <br />2 Loads: <br />Existing Roof Dead Loads:2 x 4 Rafters @ 24" OC 0.7 psf1/2" Roof Sheathing 1.7 psfRoof Felt 1.5 psfComposition5.0 psfMiscellaneous3.1 psfTotal12.0 psf <br />Existing Snow Load:0.0 psfExisting Roof Live Load:20.0 psfProposed Roof Live Load: 20.0 psf <br />Wind Load: Using CBC 2022 (ASCE 7-22), Chapter 29: Wind Loads on Rooftop Equipment, the following wind pressures were calculated.p = qh (GCp) (ge) (ga) = 7.82 -40.21 psfqh = 0.00256 Kz Kzt Kd Ke V2 =19.64 psfKz = 0.85 (0-15 = 0.85, 20 = 0.90, 25 = 0.94, 30 = 0.98, 40 = 1.04)GCp =0.7 -3.6 (Roof pitch = 18 deg, Zone = 2, Aeff = 21.1 sf) <br />ge = 1.50 <br />ga = 0.80 <br />Lag Bolt Capacity:5/16" lag bolt capacity = 270 lbs per inch embedmentWith 2 1/2" minimum embedment, capacity = 675 lbsRequired Capacity:40.21 psf *20 modules *21.1 sf =16967.6 lbs16967.6 lbs /28 lag bolt connections = 606.0 lbsThe pull-out capacity of the 5/16" lag bolts with a minimum 2 1/2" embedment into the roof rafter is sufficientto meet the demand of the wind uplift force on the solar system. <br />Seismic Load: Per the CEBC 2022 Section 503.4, if the demand-capacity ratio of the lateral load-carrying elements increases less than 10% due to the addition of the solar system, no special provisions or structuralmodifications are required.Existing Roof Weight = 12.0 psf *2773 sf =33276 lbsWeight of Solar System = 20 modules *50.2 lbs +211 lbs of racking = 1215 lbs1215lbs / 33276 lbs =0.04The increase in load from the solar system will not increase the demand-capacity ratio of the existing lateralload-carrying elements by over 10%. <br />NOTICE: VISION CIVIL ENGINEERING: JENNIFER KEMME, PEANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300,JENKEMME@VISIONCE.COMCIVIL ENGINEERING IS STRICTLY PROHIBITED.RCE 73054, EXP 12/31/24 <br />Prepared by JENNIFER KEMME 10/3/2023 Page 1 <br />3002 W Cubbon St - <br />2018128112/6/2023