My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3002 W Cubbon St - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cubbon St
>
3002 W Cubbon St
>
3002 W Cubbon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:06:31 PM
Creation date
6/1/2025 12:06:25 PM
Metadata
Fields
Template:
Plan
Permit Number
20181281
101117158
Full Address
3002 W Cubbon St
Document Relationships
101117158 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cubbon St\3002 W Cubbon St
20181281 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cubbon St\3002 W Cubbon St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM <br />NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROMHIS SITE INSPECTION. <br />3 Analysis of Existing Rafter Capacity:PV SOLAR ARRAY: YAM RESIDENCE3002 W. CUBBON STREET, SANTA ANA, CA 92705 <br />Rafter Loads:Solar system dead load = 1215 lbs /28 lag bolts total =43.4 lbs at each lag boltExisting roof dead load =12 psfSnow load = 0 psfRoof live load =20 psfWind load = 117.8 lbs,606.0 lbsRafter span =7.0 ft <br />Load Combinations That Apply:#1: D + Lr or S = 12 psf +43.4 lbs at each lag bolt +20.0 psf#2: D + 0.75(0.6W) + 0.75(Lr or S) = (12 psf +43.4 lbs at each lag bolt) + (0.75 (0.6)117.8 lbs at each lag bolt) + (0.75 (20 psf))#3: 0.6D + 0.6W = 0.6 (12 psf + 43.4 lbs at each lag bolt) - (0.6)606.0 lbs at each lag bolt <br />Calculated Maximum Bending Moment:#1:196.0 ft/lbs +75.9 ft/lbs = 271.9 ft/lbs[(32 psf) (7 ft^2)] / 8 = 196.0 ft/lbs[(43.39 lbs) (7.0 ft)] / 4 =75.9 ft/lbs#2:73.5 ft/lbs +75.9 ft/lbs +92.8 ft/lbs +91.9 ft/lbs =334.1 ft/lbs[(12 psf) (7 ft^2)] / 8 = 73.5 ft/lbs[(43.39 lbs) (7.0 ft)] / 4 =75.9 ft/lbs117.8 lbs) (7 ft)] / 4 = 92.8 ft/lbs0.75 [(20 psf) (7 ft^2)] / 8 = 91.9 ft/lbs#3:44.1 ft/lbs +45.6 ft/lbs -636.3 ft/lbs =-546.6 ft/lbs0.6 [(12 psf) (7 ft^2)] / 8 = 44.1 ft/lbs0.6 [(43.39 lbs) (7.0 ft)] / 4 =45.6 ft/lbs0.6 [(606.0 lbs) (7 ft)] / 4 =636.3 ft/lbs <br />Section Required:546.6 ft/lbs (12) (0.7) / 1518 psi = 3.0 cu inSection Provided:1.5 (3.5 ^2) / 6 =3.1 cu in3.1 cu in >3.0 cu in, OK <br />Calculated Deflection:[5(32 psf / 12) (84 in^4)] / [384 (1200000) (5.4 )] =0.27 inAllowable Deflection:84 in / 240 = 0.35 in0.35 in >0.27 in, OK <br />NOTICE: VISION CIVIL ENGINEERING: JENNIFER KEMME, PEANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300,JENKEMME@VISIONCE.COMCIVIL ENGINEERING IS STRICTLY PROHIBITED.RCE 73054, EXP 12/31/24 <br />0.75 [(0.6)( <br />Prepared by JENNIFER KEMME 10/3/2023 Page 2 <br />3002 W Cubbon St - <br />2018128112/6/2023
The URL can be used to link to this page
Your browser does not support the video tag.