My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3002 W Cubbon St - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cubbon St
>
3002 W Cubbon St
>
3002 W Cubbon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:06:31 PM
Creation date
6/1/2025 12:06:25 PM
Metadata
Fields
Template:
Plan
Permit Number
20181281
101117158
Full Address
3002 W Cubbon St
Document Relationships
101117158 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cubbon St\3002 W Cubbon St
20181281 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cubbon St\3002 W Cubbon St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SCOPE OF WORK: <br />INSTALL (20) Q.CELLS Q.PEAK DUO BLK ML-G10+ 405 SOLAR ELECTRIC MODULES AND <br />(20) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY COMPOSITION <br />ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, <br />CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US <br />INVERTER WITH INTEGRATED DC DISCONNECT, (1) SOLAREDGE ENERGYBANK <br />BAT-10K1PSOB-01 BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. <br />HOMEOWNER: TYNA YAM <br />PH: 714.542.0788 <br />ADDRESS: 3002 W. CUBBON STREET <br />SANTA ANA, CA 92705 <br />DATE: 10/12/23 <br />ING ELECTRIC INC <br />1451 DOMIGUEZ RANCH ROAD <br />CORONA, CA 92882 <br />PH: 951.399.2555 <br />NORAN ING C10 - 1048140 <br />VICINITY MAP <br />YAM <br />RESIDENCE <br />SHEET INDEX: <br />SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK <br />SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL <br />SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />SHEET 4 SIGNS <br />SHEET 5 CALCULATIONS <br />ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />STRUCTURAL REPORT <br />NTS <br />SHEET <br />NOTICE: <br />ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE <br />WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. <br />1 OF 5 <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />(20) Q.CELLS Q.PEAK DUO BLK ML-G10+ 405 <br />PEAK POWER = 405 W <br />MAX OPERATING CURRENT = 10.83 A <br />MAX OPERATING VOLTAGE = 37.39 V <br />OPEN CIRCUIT VOLTAGE = 45.34 V <br />SHORT CIRCUIT CURRENT = 11.17 A <br />MAX SERIES FUSE RATING = 20 A <br />TEMP. COEFF. OF Voc = -0.27%/K <br />DIMENSIONS = 74.0" X 41.1" X 1.3" <br />WEIGHT = 48.5 LBS <br />GENERAL NOTES: <br />1. THIS SYSTEM COMPLIES WITH THE 2022 CRC, 2022 CBC, 2022 CFC, AND THE 2022 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />99499PV <br />INVERTER/DC DISCONNECT: (1) SOLAREDGE ENERGY HUB SE7600H-US <br />MAX DC INPUT VOLTAGE = 480 V <br />NOMINAL DC INPUT VOLTAGE = 400 V <br />MAX DC INPUT CURRENT = 20.0 A <br />DC DISCONNECT MAX INPUT CURRENT = 45.0 A <br />NUMBER OF DC INPUTS = 2 <br />RATED AC POWER = 7600 W <br />AC VOLTAGE = 240 V <br />MAX AC OUTPUT CURRENT = 32.0 A <br />NEMA 4X ENCLOSURE <br />DIMENSIONS = 17.7" X 14.6" X 6.8" <br />WEIGHT = 26 LBS <br />PHOTOVOLTAIC SOLAR PROJECT INFORMATION: <br />SYSTEM SIZE: 8.100 kW (DC), 7.600 kW (AC) <br />MODULES: <br />MODULE ADD-ON:(20) SOLAREDGE S440 <br />DC POWER OPTIMIZERS <br />MAX DC INPUT VOLTAGE = 60 V <br />OPERATING VOLTAGE RANGE = 8 V - 60 V <br />MAX DC INPUT CURRENT = 14.5 A <br />MAX DC OUTPUT CURRENT = 15 A <br />DC OUTPUT VOLTAGE = 380 V <br />MAX POWER PER STRING <br />(CONTROLLED BY INVERTER) = 6000 W <br />NEMA 6P ENCLOSURE <br />DIMENSIONS = 5.1" X 6.1" X 1.2" <br />WEIGHT = 1.6 LB <br />ARRAY:INSTALLED WEIGHT = 2.9 PSF <br />ROOF COVERAGE = 425 SF, <br />ARRAYS COVER 15% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: K2 CROSSRAIL 48X RAIL <br />K2 EVERFLASH ECOMP KIT ATTACHMENTS <br />5 16" STAINLESS STEEL LAG BOLTS @ <br />72" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 1 STORY, ASPHALT SHINGLE <br />2 X 4 RAFTERS @ 24" OC <br />BATTERY:(1) SOLAREDGE ENERGYBANK BAT-10K1PSOB-01 <br />USABLE ENERGY = 9.7 kWh <br />PEAK POWER = 5 kW <br />MAX POWER = 7.5 kW <br />IP65/NEMA 3R ENCLOSURE <br />DIMENSIONS = 31.1" X 46.4" X 9.8" <br />WEIGHT = 267 LBS <br />Bldg# 101117158 <br />Issued 12/05/23 <br />Elec# 20181281 MSmith <br />Issued 11/28/23 <br />The scope of the plans is for the installation of the <br />solar photovoltaic system only and the approval is <br />subject to compliance with all applicable city and state <br />codes and regulations regarding construction. The <br />approval of the plans does not constitute any <br />certification of the accuracy, completeness, or building <br />permit status of the existing buildings and structures <br />as shown. <br />3002 W Cubbon St - <br />2018128112/6/2023
The URL can be used to link to this page
Your browser does not support the video tag.