Laserfiche WebLink
PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />ONTIVEROS <br />RESIDENCE <br />4.800 DC kW <br />4.454 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />3409 <br />S OLIVE ST, <br />SANTA ANA, CA <br />92707 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP162149 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN07-28-23 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Renewable Power AZ <br />CRCR106 & Business and <br />Professions Code 5536.2 <br />REQUIRED <br />SIGNAGE <br />E3 <br />PV ARRAY <br />JBOX <br />1 <br />5 <br />INVERTER <br />DC <br />DISCO <br />3 <br />4 <br />4 <br />AC <br />DISCO <br />M <br />MAIN SERVICE <br />PANEL <br />2 <br />6 <br />SEE PAGE E3.1 <br />1 COMBINER BOX/CIRCUITS/ <br />CONDUIT COMBINER <br />BOX/ENCLOSURES/EMT <br />ENCLOSURE <br />WARNING! <br />TERMINAL ON THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />ELECTRICAL S HOCK HAZ ARD <br />CEC 706.15(C)(4) and CEC 690.13(B) <br />CEC 110.27(C) & OSHA 1910.145(f)(7) <br />WARNING! <br />TURN OF F P HOTOVOLTAIC <br />ACDISCONNECT P RIOR T O <br />WORKING INS IDE P ANEL <br />2 BUILDING/STRUCTURE <br />CAUTION <br />MULTIPLE SOURCES OF POWER <br />AC DISCONNECT <br />INVERTER <br />PV ARRAY <br />UTILITY <br />AC DISCONNECT <br />NORTH <br />CEC 705.10 & 690.56(A)(B) <br />3 EMT/CONDUIT RACEWAYS <br />4 <br />CEC 690.31(O)(2) <br />CEC 690.31(O)(2) <br />SOLAR PV DC CIRCUIT <br />PHOTOVOLTAIC POWER SOURCE <br />DC DISCONNECT <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />IFC 605.11.3.1(1) & CEC 690.56(C) <br />RAPID SHUTDOWN FOR <br />SOLAR PV SYSTEM <br />CEC 690.56(C)(2)) <br />PHOTOVOLTAIC <br />DC DISCONNECT <br />CEC 690.13(B) <br />MAIN SERVICE DISCONNECT <br />WARNING! <br />TERMINAL ON THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />ELECTRICAL S HOCK HAZ ARD <br />CEC 706.15(C)(4) and CEC 690.13(B) <br />CEC 110.27(C) & OSHA 1910.145(f)(7) <br />WARNING! <br />TURN OF F P HOTOVOLTAIC <br />ACDISCONNECT P RIOR T O <br />WORKING INS IDE P ANEL <br />DO NOT DISCONNECT <br />UNDER LOAD <br />CEC 690.15 (B) & CEC 690.33(D)(2) <br />WARNING !DUAL POWER SOURCE <br />SECOND SOURCE I S PHOTOVOLTAIC SYSTEM <br />CEC 705.12(C) & NEC 690.59 <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />PHOTOVOLTAIC AC DISCONNECT <br />RATED AC OUTPUT CURRENT <br />NORMAL OPERATING VOLTAGE <br />A <br />V <br />16 <br />240 <br />CEC 690.54 <br />CEC 690.13(B) <br />POWER SOURCE OUTPUT <br />CONNECTION. D O NOT <br />RELOCATE THIS <br />OVERCURRENT D EVICE. <br />WARNING! <br />CEC 705.12 (B)(3)(2MAXIMUM DC VOLTAGE <br />OF PV SYSTEM <br />CEC 690.13(B) <br />480 V <br />WARNING! <br />THE DISCONNECTION OF THE <br />GROUNDED CONDUCTOR(S) <br />MAYRESULT IN OVERVOLTAGE <br />ONTHE EQUIPMENT <br />CEC 690.31(E) <br />WARNING ! <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />ELECTRI CAL SHOCK HAZARD <br />DC V OLTAGE I S A LWAYS PRESENT <br />WHEN S O LAR MO DULES <br />ARE E XP OSED TO S UNLIG HT <br />CEC 690.13(B) <br />PHOTOVOLTAIC AC DISCONNECT <br />RATED AC OUTPUT CURRENT <br />NORMAL OPERATING VOLTAGE <br />A <br />V <br />16 <br />240 <br />CEC 690.54 <br />5 INVERTER <br />6 7AC DISCONNECT/BREAKER/ <br />POINTS OF CONNECTION <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />WARNING! <br />TERMINAL ON THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />ELECTRICAL S HOCK HAZ ARD <br />CEC 706.15(C)(4) and CEC 690.13(B) <br />CEC 690.13(B) <br />PHOTOVOLTAIC AC DISCONNECT <br />RATED AC OUTPUT CURRENT <br />NORMAL OPERATING VOLTAGE <br />A <br />V <br />16 <br />240 <br />CEC 690.54 <br />WARNING! <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES: <br /> TOTAL RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN SUPPLY <br />OVERCURRENT DEVICES EXCLUDING <br />MAIN POWER SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />CEC 705.12(B)(3)(3) <br />RAPID SHUTDOWN FOR <br />SOLAR PV SYSTEM <br />CEC 690.56(C)(2)) <br />RAPID SHUTDOWN FOR <br />SOLAR PV SYSTEM <br />CEC 690.56(C)(2)) <br />SUBPANEL <br />2 7 <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />CEC 690.13(B) <br />8 <br />8 <br />UTILITY METER <br />7 <br />G:\My Drive\2023\0-TITAN\502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW-MS400-12-SE3.8\23-502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW.dwg <br />3409 S Olive St <br />08/29/23