My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3409 S Olive St - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Olive St
>
3409 S Olive St
>
3409 S Olive St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:07:38 PM
Creation date
6/1/2025 12:07:30 PM
Metadata
Fields
Template:
Plan
Permit Number
20180759
101116377
Full Address
3409 S Olive St
Document Relationships
101116377 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Olive St\3409 S Olive St
20180759 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Olive St\3409 S Olive St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:07 PM
Modified:
5/30/2025 4:18 PM
Text:
WWW.TITANSOLARPOWER.COM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />ONTIVEROS <br />RESIDENCE <br />4.800 DC kW <br />4.454 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />3409 <br />S OLIVE ST, <br />SANTA ANA, CA <br />92707 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP162149 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN07-28-23 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Renewable Power AZ <br />CRCR106 & Business and <br />Professions Code 5536.2 <br />DIRECTORY PLACARD <br />6" <br />6" <br />CAUTION <br />S <br /> <br />O <br />L <br />I <br />V <br />E <br />S <br />T <br />DR <br />I <br />V <br />E <br />W <br />A <br />Y <br />ADDRESS: 3409 S OLIVE ST <br />MAIN SERVICE <br />PANEL INVERTER <br />2 LABELING REQUIREMENTS <br />2022 CODE REFERENCE <br />CEC 690.13(B) <br />EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) <br />POSITION AND BE PERMANENTLY MARKED "PV SYSTEM DISCONNECT" OR EQUIVALENT. ADDITIONAL MARKINGS SHALL <br />BE PERMITTED BASED UPON THE SPECIFIC SYSTEM CONFIGURATION. FOR PV SYSTEM DISCONNECTING MEANS WHERE <br />THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION.THE WARNING SIGN(S) OR LABEL(S) SHALL <br />COMPLY WITH 110.21(B). <br />CEC 690.56(C) <br />BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH <br />THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF <br />RAPID SHUTDOWN INITIATION DEVICES. <br />CEC 690.31(B)(1) <br />PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED AT ALL TERMINATION, CONNECTION, AND SPLICE POINTS BY COLOR <br />CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. CONDUCTORS RELYING ON OTHER THAN COLOR <br />CODING FOR POLARITY IDENTIFICATION SHALL BE IDENTIFIED BY AN APPROVED PERMANENT MARKING MEANS SUCH AS <br />LABELING, SLEEVING, OR SHRINK-TUBING THAT IS SUITABLE FOR THE CONDUCTOR SIZE. <br />CEC 690.31(D)(2) <br />UNLESS LOCATED AND ARRANGED SO THE PURPOSE IS EVIDENT, THE FOLLOWING WIRING METHODS AND <br />ENCLOSURES THAT CONTAIN PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE MARKED WITH THE WORDING <br />PHOTOVOLTAIC POWER SOURCE OR SOLAR PV DC CIRCUIT BY MEANS OF PERMANENTLY AFFIXED LABELS OR OTHER <br />APPROVED PERMANENT MARKING: <br />(1) EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS <br />(2) COVERS OR ENCLOSURES OF PULL BOXES AND JUNCTION BOXES <br />(3) CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. <br />THE LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION. ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A <br />MINIMUM HEIGHT OF 9.5 MM (3∕8 IN.) IN WHITE ON A RED BACKGROUND. LABELS SHALL APPEAR ON EVERY SECTION <br />OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. SPACING <br />BETWEEN LABELS OR MARKINGS, OR BETWEEN A LABEL AND A MARKING, SHALL NOT BE MORE THAN 3 M (10 FT). <br />LABELS REQUIRED BY THIS SECTION SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. <br />CEC 690.31(E) <br />SOLIDLY GROUNDED BIPOLAR PV SYSTEMS SHALL BE CLEARLY MARKED WITH A PERMANENT, LEGIBLE WARNING <br />NOTICE INDICATING THAT THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE <br />ON THE EQUIPMENT. <br />CEC 690.33(D)(2)INTERRUPTION OF CIRCUIT. CONNECTORS SHALL BE A TYPE THAT REQUIRES THE USE OF A TOOL TO OPEN AND <br />MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING.” <br />CEC 690.52 ALTERNATING-CURRENT MODULES SHALL BE MARKED WITH IDENTIFICATION OF TERMINALS OR LEADS AND WITH <br />IDENTIFICATION OF THE FOLLOWING RATINGS. <br />CEC 690.53 <br />A PERMANENT READILY VISIBLE LABEL INDICATING THE HIGHEST MAXIMUM DC VOLTAGE IN <br />A PV SYSTEM, CALCULATED IN ACCORDANCE WITH 690.7, SHALL BE PROVIDED BY THE INSTALLER AT ONE OF THE <br />FOLLOWING LOCATIONS: <br />(1) DC PV SYSTEM DISCONNECTING MEANS <br />(2) PV SYSTEM ELECTRONIC POWER CONVERSION EQUIPMENT <br />(3) DISTRIBUTION EQUIPMENT ASSOCIATED WITH THE PV SYSTEM. <br />CEC 690.54 <br />ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION WITH OTHER SOURCES SHALL BE MARKED AS AN <br />ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT <br />CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. <br />CEC 690.55 THE PV SYSTEM OUTPUT CIRCUIT CONDUCTORS SHALL BE MARKED TO INDICATE POLARITY WHERE CONNECTED TO <br />ENERGY STORAGE SYSTEMS. <br />CEC 690.56(B) PLAQUES OR DIRECTORIES SHALL BE INSTALLED IN ACCORDANCE WITH 705.10 AND 712.10. <br />CEC 690.56(C) THE TYPE OF PV SYSTEM IS SHOWN IN FIGURE 690.56 (C). <br />CEC 690.56(C)(2) <br />A RAPID SHUTDOWN INITIATION DEVICE SHALL HAVE A LABEL LOCATED ON OR NO MORE <br />THAN 1 M (3 FT) FROM THE INITIATION DEVICE THAT INCLUDES THE FOLLOWING WORDING: <br />RAPID SHUTDOWN FOR SOLAR PV SYSTEM <br />THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A <br />MINIMUM HEIGHT OF 9.5 MM (3∕8 IN.), IN WHITE ON RED BACKGROUND. <br />CEC 690.59 PV SYSTEMS CONNECTED TO OTHER SOURCES SHALL BE INSTALLED IN ACCORDANCE WITH PARTS I AND II OF ARTICLE <br />705. <br />CEC 705.12(B)(3)(3) <br />THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT DEVICES ON PANELBOARDS, <br />BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR, <br />SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. THE RATING OF THE OVERCURRENT DEVICEPROTECTING THE <br />BUSBAR SHALL NOT EXCEED THE RATING OF THE BUSBAR. PERMANENT WARNING LABELSSHALL BE APPLIED TO <br />DISTRIBUTION EQUIPMENT DISPLAYING THE FOLLOWING OR EQUIVALENT WORDING: <br />WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICESHALL NOT <br />EXCEED AMPACITY OF BUSBAR. <br />CEC 705.12(D)SUITABLE FOR BACKFEED. FUSED DISCONNECTS, UNLESS OTHERWISE MARKED, SHALL BE <br />CONSIDERED SUITABLE FOR BACKFEED. <br />CEC 706.15(C) <br />EACH ESS DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IT IS IN THE <br />OPEN (ON) OR CLOSED (OFF) POSITION AND BE PERMANENTLY MARKED <br />“ENERGY STORAGE SYSTEM DISCONNECT" <br />THE DISCONNECTING MEANS SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE THE FOLLOWING: <br />NOMINAL ESS AC VOLTAGE AND MAXIMUM ESS DC VOLTAGE <br />AVAILABLE FAULT CURRENT DERIVED FROM THE ESS <br />AN ARC-FLASH LABEL APPLIED IN ACCORDANCE WITH ACCEPTABLE INDUSTRY PRACTICE <br />DATA CALCULATION WAS PERFORMED. <br />CEC 110.27(C) <br />ENTRANCES TO ROOMS OR OTHER GUARDED LOCATIONS THAT CONTAIN EXPOSED LIVE <br />PARTS SHALL BE MARKED WITH CONSPICUOUS WARNING SIGNS FORBIDDING UNQUALIFIED PERSONS TO <br />ENTER. <br />CEC 705.10 <br />A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT A BUILDING SUPPLIED BY A STAND-ALONE <br />SYSTEM AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN APPROVED READILY VISIBLE LOCATION. <br />THE PLAQUE OR DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER SOURCE DISCONNECTING <br />MEANS FOR THE PREMISES OR BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE <br />SOURCES. THE <br />MARKING SHALL COMPLY WITH 110.21(B). <br />CEC 705.12(C) <br />EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR <br />CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE <br />OF ALL SOURCES. <br />CEC 705.12(B)(3)(3) <br />PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT DISPLAYING THE FOLLOWING <br />OR EQUIVALENT WORDING: THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL <br />OVERCURRENT DEVICES EXCLUDING MAIN <br />POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR. <br />CEC 705.12(B)(3)(2) <br />A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE <br />BACK-FED BREAKER FROM THE INVERTER POWER SOURCE THAT DISPLAYS THE FOLLOWING OR EQUIVALENT <br />WORDING: <br />“WARNING: POWER OUTPUT CONNECTION. <br />DO NOT RELOCATE THIS OVERCURRENT DRIVE.” <br />REQUIRED <br />DIRECTORY <br />E3.1 <br />MULTIPLE SOURCES OF POWER <br />CEC 705.10 & 690.56(A)(B) <br />705.10 IDENTIFICATION OF POWER SOURCES <br />A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN APPROVED READILY VISIBLE LOCATION. THE <br />PLAQUE OR DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS FOR THE BUILDING OR STRUCTURE AND BE <br />GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. THE PLAQUE OR DIRECTORY SHALL BE MARKED WITH THE WORDING <br />"CAUTION: MULTIPLE SOURCES OF POWER." <br />ANY POSTED DIAGRAMS SHALL BE CORRECTLY ORIENTED WITH RESPECT TO THE DIAGRAM'S LOCATION. THE MARKING SHALL COMPLY WITH 110.21(B). <br />EXCEPTION: INSTALLATIONS WITH MULTIPLE CO-LOCATED POWER PRODUCTION SOURCES SHALL BE PERMITTED TO BE IDENTIFIED AS A GROUP(S). THE PLAQUE <br />OR DIRECTORY SHALL NOT BE REQUIRED TO IDENTIFY EACH POWER SOURCE INDIVIDUALLY. <br />SOLAR <br />ARRAY <br />AC DISCO <br />SUBPANEL <br />G:\My Drive\2023\0-TITAN\502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW-MS400-12-SE3.8\23-502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW.dwg <br />3409 S Olive St <br />08/29/23
The URL can be used to link to this page
Your browser does not support the video tag.