My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3600 W Segerstrom Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Segerstrom Ave
>
3600 W Segerstrom Ave
>
3600 W Segerstrom Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:07:40 PM
Creation date
6/1/2025 12:07:33 PM
Metadata
Fields
Template:
Plan
Permit Number
20181380
101117310
Full Address
3600 W Segerstrom Ave
Document Relationships
101117310 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Segerstrom Ave\3600 W Segerstrom Ave
20181380 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Segerstrom Ave\3600 W Segerstrom Ave
Polygon
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:07 PM
Modified:
5/30/2025 4:23 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CLIENT APPROVAL <br />x_________________ <br />Client Initials <br />To scale on 24x36 paper <br />X___________________________ <br />VICINITY MAP: PROJECT SCOPE:DRAWING INDEX PERMITTING / PLANNING NOTES: <br />PROJECT ADDRESS AERIAL PHOTO: PROJECT TEAM: <br />1.THIS PV SYSTEM INSTALLATION IS SUBJECT TO INSPECTION BY THE AUTHORITY HAVING JURISDICTION AND <br />SOUTHERN CALIFORNIA EDISON <br />2.THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODE VERSIONS: <br />2022 CALIFORNIA BUILDING CODE (CBC 2022) <br />2022 CALIFORNIA ELECTRIC CODE (CEC 2022) <br />2022 CALIFORNIA FIRE CODE (CFC 2022) <br />2022 CALIFORNIA ENERGY CODE (CEnC 2022) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG 2022) <br />2022 CALIFORNIA PLUMBING CODE (CPC 2022) <br />2022 CALIFORNIA MECHANICAL CODE (CMC 2022) <br />AUTHORITY HAVING JURISDICTION <br />3.110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A <br />NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL <br />SAFETY HEALTH ADMINISTRATION. <br />4.ELECTRICAL EQUIPMENT SHALL BE LISTED OR CERTIFIED BY A RECOGNIZED ELECTRICAL TESTING <br />LABORATORY OR APPROVED BY THE DEPARTMENT. <br />5.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES, TRANSFORMERS, <br />VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ECT.) OR TO THE LOCATION OF THE HOOK-UP. THE <br />CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE <br />LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR <br />ADDITIONAL EXPENSES. <br />6.A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE <br />AVAILABLE AT THE JOB SITE. <br />7.INSTALLATION OF THE PV SYSTEM IN PARALLEL WITH THE UTILITY POWER SHALL BE <br />INSTALLED ONLY BY QUALIFIED PERSONS. 705.6. <br />8.THE OUTPUT CHARACTERISTICS OF THE PV SYSTEM SHALL BE COMPATIBLE WITH THE <br />VOLTAGE, WAVE SHAPE, AND FREQUENCY OF THAT OF THE UTILITY OUTPUT. 705.14. <br />9.INTERCONNECTED ELECTRIC POWER PRODUCTION SOURCES SHALL BE GROUNDED IN <br />ACCORDANCE WITH ARTICLE 250. 705.50. <br />SITE CONTACT: <br />CONTRACTOR: <br />Confidentiality Statement: <br />12/6/2023 5:54:20 PM <br />Title Sheet <br />Ma <br />i <br />n <br /> <br />E <br />l <br />e <br />c <br />t <br />r <br />i <br />c <br /> <br />- <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />36 <br />0 <br />0 <br /> <br />W <br /> <br />S <br />E <br />G <br />E <br />R <br />S <br />T <br />R <br />O <br />M <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />T101 <br />Main Electric -Santa Ana <br />3600 W SEGERSTROM AVE, SANTA ANA, CA 92704 <br />SOLAR ELECTRIC SYSTEM PROJECT - 135.88kW DC STC RATING / 126.748kW AC CEC RATING <br />PHONE: XXX-XXX-XXXX <br />SOLAR ELECTRIC SYSTEM <br />THIS PROJECT ENTAILS THE INSTALLATION OF A PHOTOVOLTAIC SYSTEM AT Main Electric - <br />Santa Ana THE SYSTEM WILL NOT BE A NET ELECTRICITY EXPORTER TO THE UTILITY GRID. <br />THIS INSTALLATION CONSISTS OF A NEW ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM. <br />THE PV SYSTEM IS STATIC MOUNTED. <br />THIS SYSTEM WILL BE INTERCONNECTED TO AND WILL BE OPERATED IN PARALLEL WITH <br />THE SCE ELECTRIC GRID PER THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE <br />AND UTILITY INTERCONNECT AGREEMENT <br />CONDITIONS OF APPROVAL: <br />1.ALL CONSTRUCTION SHALL OCCUR BETWEEN THE HOURS OF 7AM & 7PM, EXCEPT FOR <br />THE PURPOSE OF EMERGENCIES. <br />This drawing is the property of SOL <br />IRVINE. This information is <br />confidential and is to be used only <br />in connection with work described <br />by SOL IRVINE. No part is to be <br />disclosed to others without written <br />permission from SOL IRVINE <br />SOL IRVINE <br />LIC # C46 -1050892 <br />EXP: 3/31/2025 <br />SOL IRVINE <br />SOL IRVINE <br />16200 SCIENTIFIC <br />IRVINE, CA 92618 <br />TEL: 760-271-6580 <br />LIC # C46 -1050892 <br />Sheet #Sheet Name <br />T101 Title Sheet <br />T102 Notes <br />A100 Site Plan <br />A101 Array Layout <br />S1.0 Structural Sheet <br />S1.1 Structural Sheet <br />S2.0 Structural Sheet <br />E101 Electrical Layout <br />E201 Interconnection SLD <br />E301 Signage <br />SP101 Spec Sheets <br />SP102 Spec Sheets <br />SP103 Spec Sheets <br />SP104 Spec Sheets <br />ELECTRICAL: <br />AXIS SOLAR DESIGN <br />27281 LAS RAMBLAS, SUITE 200 <br />MISSION VIEJO, CA 92691 <br />TEL: 323-484-2947 <br />CHAD BUCCINE <br />LICENSE# E20115 <br />No <br />. <br /> <br />De <br />sc <br />r <br />i <br />p <br />t <br />i <br />o <br />n <br />Da <br />t <br />e <br />1 <br />A <br />H <br />J <br /> C <br />o <br />r <br />r <br />e <br />c <br />tio <br />n <br /> <br />1 <br />2 <br />/ <br />6 <br />/ <br />2 <br />3 <br />PARCEL # 414-211-14 <br />PROJECT TOTAL: <br />SYSTEM SIZE: <br />135.88 kW STC DC <br />126.748 kW CEC AC <br />PANEL SPECS: <br />(316) MISSION SOLAR ENERGY LLC, MSE430SX9Z <br />VMP: 40.32V, VOC: 49.28V, IMP: 10.66A, ISC: 11.24A <br />STC: 430W, PTC: 401.1W <br />INVERTER SPECS: <br />(2) SMA AMERICA, STP 62-US-41 [480V] <br />480/277V, 3PH, 4W, MAX OUTPUT CURRENT = 80A <br />MAXIMUM CONTINUOUS OUTPUT POWER @ UTILITY POWER FACTOR: 62.5 kW <br />CEC WEIGHTED EFFICIENCEY: 97.5% <br />BUILDING INFO: <br />APN: 414-211-14 <br />OCCUPANCY: B <br />CONSTRUCTION TYPE: V <br />TWO STORIES <br />Bldg# 101117310 <br />Issued 01/11/24 <br />Elec# 20181380 <br />Issued 01/10/24 <br /> <br />APPROVALS: <br />PLNG - FArias <br />BLDG - JLo <br />ELEC - MSmith <br />3600 W Segerstrom Ave - <br />101117310 & 201813801/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.