My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3600 W Segerstrom Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Segerstrom Ave
>
3600 W Segerstrom Ave
>
3600 W Segerstrom Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:07:40 PM
Creation date
6/1/2025 12:07:33 PM
Metadata
Fields
Template:
Plan
Permit Number
20181380
101117310
Full Address
3600 W Segerstrom Ave
Document Relationships
101117310 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Segerstrom Ave\3600 W Segerstrom Ave
20181380 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Segerstrom Ave\3600 W Segerstrom Ave
Polygon
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:07 PM
Modified:
5/30/2025 4:23 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CAUTION <br />MULTIPLE SOURCES OF POWER <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN. DANGEROUS VOLTAGE <br />MAY BE PRESENT AT ALL TIMES. <br />"WARNING" <br />PHOTOVOLTAIC ARRAY <br />DISCONNECTION OF NEUTRAL OR GROUNDED CONDUCTORS MAY RESULT IN <br />OVERVOLTAGE ON ARRAY OR INVERTER <br />6"X8" TYP -CEC 705.10 <br />12 <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />690.13(B), 690.54 <br />RATED AC OUTPUT <br />CURRENT <br />NOMINAL OPERATING <br />AC VOLTAGE <br />8 <br />480V <br />160A <br />NOTES <br />1.ARTICLES 690 AND 705 MARKINGS SHOWN HEREON <br />2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: <br />A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE <br />PRINTED LETTERS OR ELECTRO-PLATING <br />B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK UON <br />C.ARIAL FONT <br />3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE <br />LOCATIONS SPECIFIED. <br />4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING <br />PERMANENT ADHESIVE, POP-RIVETS, OR SCREWS <br />M <br />JBOX OR <br />COMBINER <br />INVERTER <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />ORANGE WARNING AREA, 690.13(B) <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />! <br />ORANGE WARNING AREA, 110.27(C) <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />ORANGE WARNING AREA, 690.13(B) <br />DC VOLTAGE IS ALWAYS <br />PRESENT WHEN SOLAR <br />MODULES ARE EXPOSED TO <br />SUNLIGHT <br />PHOTOVOLTAIC <br />690.13(B) <br />DC DISCONNECT <br />MAXIMUM VOLTAGE <br />MAXIMUM CIRCUIT <br />CURRENT <br />MAX RATED OUTPUT <br />CURRENT OF THE CHARGE <br />CONTROLLER OR DC-TO-DC <br />CONVERTER (IF INSTALLED) <br />690.53 <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />REFLECTIVE STICKER, 690.31(G)(3)(4) <br />WARNING! <br />DUAL POWER SOURCE <br />SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM <br />ORANGE WARNING AREA, 705.12(B)(3) <br />ARRAY <br />DC <br />DISCONNECT <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />1 <br />6 <br />34 <br />2 <br />7 <br />9 <br />10 <br />5 <br />SOLAR SUB <br />PANEL1 <br />1 <br />27 <br />6 725.76V <br />11.24A <br />15A <br />RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br />690.56(C)(3) <br />11 <br />12 <br />SOLAR PV SYSTEM EQUIPPED WITH <br />RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUTDOWN PV <br />SYSTEM AND REDUCE SHOCK <br />HAZARD IN THE ARRAY <br />The title “SOLAR PV SYSTEM IS EQUIPPED WITH <br />RAPID SHUTDOWN” shall utilize capitalized characters with <br />a minimum height of 9.5 mm (3⁄8 in.) in black on yellow background <br />and the remaining characters shall be capitalized with <br />a minimum height of 4.8 mm (3⁄16 in.) in black on white background. <br />690.56(C)(1)(a) <br />PV10 <br />AC <br />DISCONNECT811 <br />WARNING! <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT <br />DEVICE. <br />ORANGE WARNING AREA, 705.12(B)(2)(3)(b) <br />9 <br />12 <br />(E)MAIN SERVICE <br />DISCONNECT (BLDG) <br />(N) PV DISCONNECT FOR <br />UTLITY OPERATION AND RAPID <br />SHUTDOWN INITIATION <br />PV ARRAYS <br />CLIENT APPROVAL <br />x_________________ <br />Client Initials <br />To scale on 24x36 paper <br />X___________________________ <br />Confidentiality Statement: <br />9/20/2023 1:07:02 AM <br />Signage <br />Ma <br />i <br />n <br /> <br />E <br />l <br />e <br />c <br />t <br />r <br />i <br />c <br /> <br />- <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />36 <br />0 <br />0 <br /> <br />W <br /> <br />S <br />E <br />G <br />E <br />R <br />S <br />T <br />R <br />O <br />M <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />E301 <br />This drawing is the property of SOL <br />IRVINE. This information is <br />confidential and is to be used only <br />in connection with work described <br />by SOL IRVINE. No part is to be <br />disclosed to others without written <br />permission from SOL IRVINE <br />SOL IRVINE <br />LIC # C46 -1050892 <br />EXP: 3/31/2025 <br />SOL IRVINE <br />12" = 1'-0"1 Signage - Central <br />No. <br />Descrip <br />tion <br />Date <br />3600 W Segerstrom Ave - <br />101117310 & 201813801/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.