(3) Site Pro 1 Stacked 10'-10" T-Arms - Structural Evaluation Site USID #: 214755 <br /> <br />3/1/2023 Page 3 of 4 <br />ANALYSIS METHOD <br /> <br />RISA-3D (Version 17.0.4), a commercially available analysis software package, and hand calculations were used to create <br />a three-dimensional model of the mount and calculate member stresses for the proposed loading configuration. Selected <br />calculations from this analysis are included in Appendices B & C. The following table details the information provided to <br />complete this structural analysis. This analysis is based solely on this information. <br /> <br />DOCUMENTS PROVIDED <br /> <br />Document Remarks Source <br />RF Data Sheet RFDS Name: CLL01583 v2.0, dated 1/25/2023 Smartlink Group <br />Construction Drawings Smartlink Group Site #: CLL01583 Rev. 0, dated 2/6/2023 Smartlink Group <br />Mount Design Larson Job #: UR468330 Rev. 2 Sheet #: S4, dated 2/15/2021 AT&T Mobility <br />Mount Mapping Not Provided N/A <br />Previous Mount Analysis GPD Project #: 2022723.21.214755.01 Rev. 1, dated 1/6/2023 AT&T Mobility <br />Mount Modification Drawings Not Provided N/A <br />Tower Design Larson Job #: UR468330 Rev. 2, dated 2/12/2021 AT&T Mobility <br />Previous Tower Analysis GPD Project #: 2022723.21.214755.01 Rev. 1, dated 1/6/2023 AT&T Mobility <br /> <br />ASSUMPTIONS <br /> <br />This mount structural analysis is based on the theoretical capacity of the members and is not a condition assessment of the <br />mount. This analysis is from information supplied, and therefore, its results are based on and are as accurate as that <br />supplied data. GPD has made no independent determination, nor is it required to, of its accuracy. The following <br />assumptions were made for this structural analysis. <br /> <br />1. The mount member sizes and shapes are considered accurate as supplied. The material grade is as per data <br />supplied and/or as assumed based on experience with similar mounts. <br />2. The antenna configuration is as supplied and/or as modeled in the analysis. When information was not provided, <br />the configuration was modeled based upon past experience with similar loading. <br />3. Some assumptions are made regarding antennas and mount sizes and their projected areas based on best <br />interpretation of data supplied and of best knowledge of antenna type and industry practice. <br />4. The mount has been properly maintained in accordance with TIA Standards and/or with manufacturer’s <br />specifications. <br />5. All welds and connections are assumed to develop at least the member capacity unless determined otherwise and <br />explicitly stated in this report. <br /> <br />If any of these assumptions are not valid or have been made in error, this analysis may be affected, and GPD should be <br />allowed to review any new information to determine its effect on the structural integrity of the mount. <br /> <br />4111 3%4 S Main St Unit <br />#WCC0112/13/2024