Laserfiche WebLink
520 South Main Street . Suite 2531 . Akron, Ohio 44311 . 330-572-2100 . Fax 330-572-2101 . www.GPDGroup.com <br />GPD Group, Inc. <br />Smartlink Group Chad Burton <br />3300 Irvine Avenue, Suite 300 520 South Main Street, Suite 2531 <br />Newport Beach, CA 92660 Akron, OH 44311 <br />(614) 859-1623 <br />cburton@gpdgroup.com <br />GPD# 2023723.21.214755.02 <br />March 1, 2023 <br />COMPREHENSIVE STRUCTURAL ANALYSIS REPORT <br />AT&T DESIGNATION: USID #: 214755 <br />Site FA #: 12844671 <br />Client #: CLL01583 <br />Site Name: SCE FAIRVIEW SUBSTATION <br />ANALYSIS CRITERIA: Codes: TIA-222-H & 2022 CBC <br />95 mph (3-second gust) w/ 0" ice <br />Ss = 1.277, S1 = 0.458 <br />SITE DATA: 4111 3/4 S Main St., Santa Ana, CA 92707, Orange County <br />Latitude 33° 41' 35.40" N, Longitude 117° 52' 03.57" W <br />78' Monopole <br />To whom it may concern, <br />GPD is pleased to submit this Comprehensive Structural Analysis Report to determine the structural integrity of the <br />aforementioned tower. The purpose of the analysis is to determine the suitability of the tower with the existing and proposed <br />loading configuration detailed in the analysis report. <br />Analysis Results <br />Tower Stress Level with Proposed Equipment: 79.9% Pass <br />Foundation Ratio with Proposed Equipment: 65.1% Pass <br />We at GPD appreciate the opportunity of providing our continuing professional services to you and Smartlink Group. If you <br />have any questions or need further assistance on this or any other projects, please do not hesitate to call. <br />Respectfully submitted, <br />John N. Kabak, S.E. <br />California #: S 6057 <br />3/1/2023 <br />4111 3%4 S Main St Unit <br />#WCC0112/13/2024