My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
420-430 E Dyer Rd - 101117682-83 - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
420 E Dyer Rd
>
420-430 E Dyer Rd - 101117682-83 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 10:51:53 AM
Creation date
6/1/2025 12:07:44 PM
Metadata
Fields
Template:
Plan
Permit Number
101117682
101117683
Full Address
420 E Dyer Rd
430 E Dyer Rd
Document Relationships
101117682 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\420 E Dyer Rd
101117683 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\430 E Dyer Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
? <br />W <br />G <br />?? <br />? <br />? <br />? <br />? <br />? <br />? <br />? <br />SIGN <br />G <br />W <br />W <br />CITADEL EHS <br />2525 CHERRY AVENUE, SUITE 105 <br />SIGNAL HILL, CALIFORNIA 90755 <br />PREPARED FOR: <br />INDUSTRIAL ENTERPRISES <br />3535 INLAND EMPIRE BOULEVARD <br />ONTARIO, CALIFORNIA 91764 <br />PROJECT ADDRESS: <br />420 - 430 EAST DYER ROAD <br />SANTA ANA, CALIFORNIA 92707 <br />SITE DEMOLITION <br />AND INTERIM <br />REDEVLOPMENT PLANS <br />VERSION SUMMARY <br />DRAFTER: <br />PROJECT MANAGER: <br />PRINCIPAL: <br />DATE: <br />PROJECT NUMBER: <br />C. JONES <br />C. JONES <br />12/04/2023 <br />1398.1009.0 <br />M. DROLLINGER <br />SHEET TITLE:SHEET NUMBER: <br />FULL PLOT SIZE: ARCH D (24" x 36") <br />SHEET OF 4NOT FOR CONSTRUCTION <br />VERSION DESCRIPTIONDATE <br />DRAFT 2 DRAFT - PLAN CHECK / NOT FOR CONSTRUCTION12/04/2023 <br />DRAFT 1 DRAFT - PLAN CHECK / NOT FOR CONSTRUCTION10/20/2023 <br />SITE DEMOLTION PLAN <br />2 <br />C-2 <br />C: <br />\ <br />U <br />S <br />E <br />R <br />S <br />\ <br />C <br />J <br />O <br />N <br />E <br />S <br />\ <br />D <br />E <br />S <br />K <br />T <br />O <br />P <br />\ <br />C <br />A <br />D <br />D <br /> <br />L <br />O <br />C <br />A <br />L <br />\ <br />1 <br />3 <br />9 <br />8 <br />. <br />1 <br />0 <br />0 <br />9 <br />. <br />0 <br />\ <br />1 <br />3 <br />9 <br />8 <br />. <br />1 <br />0 <br />0 <br />9 <br />. <br />0 <br /> <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />D <br />E <br />M <br />O <br />L <br />I <br />T <br />I <br />O <br />N <br /> <br />F <br />I <br />G <br />U <br />R <br />E <br />S <br />. <br />D <br />W <br />G <br />10' 20'0' 5' <br />LEGEND <br />APPROXIMATE SITE BOUNDARY <br />EXISTING CONCRETE PAVING <br />EXISTING ASPHALT PAVING <br />EXISTING FENCE <br />EXISTING BLOCK WALL <br />EXISTING GAS SERVICE <br />EXISTING ELECTRICAL SERVICE <br />EXISTING OVERHEAD ELECTRICAL <br />SERVICE <br />EXISTING WATER SERVICE <br />EXISTING SEWER SERVICE <br />EXISTING UNKNOWN UTILITY <br />EXISTING LIGHT POST <br />EXISTING SIGN <br />EXISTING WATER METER <br />EXISTING GAS METER <br />TO BE DEMOLISHED <br />TO BE PROTECTED-IN-PLACE <br />TO BE ABANDONED-IN-PLACE <br />NOTES <br />1.) LOCATION AND ALIGNMENT OF <br />EXISTING FEATURES ARE APPROXIMATE <br />AND BASED ON CURRENTLY AVAILABLE <br />INFORMATION. CONTRACTOR SHALL <br />VERIFY JOB SITE CONDITIONS BEFORE <br />BEGINNING WORK. <br />2.) CONTRACTOR SHALL COORDINATE <br />SERVICE TERMINATION WITH THE <br />RESPECTIVE UTILITY PROVIDERS. <br />3.) WATER, SEWER, AND GAS SERVICE <br />LINES SHALL BE CUT AND CAPPED IN <br />ACCORDANCE WITH ALL PERMIT <br />CONDITIONS AND APPLICABLE CODE <br />REQUIREMENTS. <br />G <br />E(OH) <br />E <br />SO <br />U <br />T <br />H <br /> <br />K <br />I <br />L <br />S <br />O <br />N <br /> <br />D <br />R <br />I <br />V <br />E <br />420 E. DYER ROAD <br />(RED HILL CAFE) <br />430 E. DYER ROAD <br />(UNIT B) <br />430 E. DYER ROAD <br />(UNIT A) <br />430 E. DYER ROAD <br />(UNIT D) <br />430 E. DYER ROAD <br />(UNIT C) <br />430 E. DYER ROAD <br />(UNIT F) <br />430 E. DYER ROAD <br />(UNIT E) <br />OFF-SITE BUILDING <br />ASPHALT-PAVED PARKING LOT <br />CONCRETE-PAVED DRIVEWAY <br />CONCRETE-PAVED DRIVEWAY <br />LANDSCAPING <br />W <br />? <br />S <br />SIGN <br />P <br />D <br />A <br />A <br />D <br />D <br />D(BY OTHERS) <br />D (BY OTHERS) <br />D <br />D <br />P <br />D <br />D <br />A <br />D <br />D <br />D <br />D <br />D <br />D <br />D <br />DD D D <br />A <br />A <br />DD <br />D <br />A <br />D <br />G <br />W <br />SITE ADDRESS: <br />420 - 430 EAST DYER ROAD, <br />SANTA ANA, CALIFORNIA 92707 <br />PARCEL NUMBER: <br />411-031-01 <br />SITE AREA: <br />0.57 ACRES <br />TOTAL BUILDING FOOTPRINT: <br />9,235 SQUARE FEET <br />(420 EAST DYER) 2,235 SQUARE FEET <br />(430 EAST DYER) 7,000 SQUARE FEET <br />SITE INFORMATIONSITE INFORMATION <br />420-430 E Dyer Rd - <br />101117682-831/9/2024
The URL can be used to link to this page
Your browser does not support the video tag.