Laserfiche WebLink
KE <br />L <br />L <br />Y <br /> <br />N <br />G <br />U <br />Y <br />E <br />N <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />52 <br />5 <br /> <br />S <br /> <br />M <br />A <br />R <br />I <br />N <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />Project Name & Address <br />Sheet Number <br />PV 2.0 <br />Sheet Name <br />DRAWN BY <br />YG <br />CO <br />U <br />N <br />T <br />Y <br />- <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DATE: 04/13/2023 <br />AH <br />J <br />- <br /> <br />O <br />R <br />A <br />N <br />G <br />E <br /> <br />C <br />O <br />U <br />N <br />T <br />Y <br />32203 VIA BENABARRE, TEMECULA <br />CA USA 92592 <br />CSLB # : 978840 <br />EMAIL: <br />JEREMY@POWERCONSULTATIONS.COM <br />TIME SAVER ELECTRIC <br />ATTACHMENT DETAIL <br />GENERAL STRUCTURAL NOTES: <br />1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE <br />ROOF FRAMING ROCK IT ECOFASTEN <br />ATTACHMENT. THE MOUNTING FEET ARE TO BE <br />SPACED AS SHOWN IN THE DETAILS, AND MUST BE <br />STAGGERED TO ADJACENT FRAMING MEMBERS TO <br />SPREAD OUT THE ADDITIONAL LOAD. <br />2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS <br />SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF <br />2-1/2" PENETRATION INTO ROOF FRAMING. <br />3. THE PROPOSED PV SYSTEM ADDS 2.6 PSF TO THE <br />ROOF FRAMING SYSTEM. <br />4. ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDER <br />NEW PV SYSTEM. <br />5. SNOW LOAD = 5 LB/SQFT <br />6. WIND SPEED = 115 MPH <br />7. EXPOSURE CATEGORY = C <br />8. MAX SPACING BETWEEN ATTACHMENTS (INCHES) = <br />48" <br />ROCK-IT SLIDE <br />FLAT TILE FLASHING <br />EPDM BONDED WASHER <br />FORMS WATERTIGHT SEAL <br />TILE BASE <br />3" <br /> <br />M <br />I <br />N <br />. <br />S 1.0 <br />1 ROCK-IT MOUNT DETAIL <br />NOT TO SCALE <br />(2) MIN 5 <br />16" SS LAG SCREW <br />TORQUE=13±2 FT-LBS. <br />PILOT HOLE BACKFILLED WITH <br />SEALANT PRIOR TO LAG INSTALLATION <br />RAIN BUSTER IS APPLIED TO THE <br />UP-SLOPE EDGE OF THE TILE BASE AS <br />WELL AS TO THE LOCATIONS <br />OF THE LAG SCREW. <br />2 1 <br />2" EMBEDMENT <br />TOP VIEW <br />COUPLING <br />CLAMP + ATTACHMENT <br />COUPLING <br />CLAMP + ATTACHMENT <br />L=PORTRAIT <br />CLAMP SPACING <br />PERMITTED <br />CLAMP SPACING <br />MODULE <br />L=LANDSCAPE CLAMP SPACING <br />MODULE <br />MODULE <br />COUPLING <br />TRUSSES <br />CLAMP <br />RAFTER <br />CANTILEVER L/3 OR LESS <br />TRUSSES <br />S 1.0 <br />5 MODULES IN PORTRAIT/LANDSCAPE <br />NOT TO SCALES 1.0 <br />4 PV SYSTEM MOUNTING DETAIL <br />NOT TO SCALE <br />S 1.0 <br />6 PV ARRAY TYP. ELEVATION <br />NOT TO SCALE <br />PV MODULE, TYP. MOUNT <br />TO FRAMING OF EXISTING <br />ROOF TYPE, PARALLEL <br />WITH PLANE OF ROOF <br />1 <br />S 1.0 <br />S 1.0 <br />7 CONDUIT MOUNTING DETAIL <br />NOT TO SCALE <br />3" MIN AND 6" MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE <br />6" MA <br />XIMU <br />M <br />U.L. LISTING FOR ECOFASTEN: 2703 <br />WEIGHT: 2.3 lb. <br />S 1.0 <br />3 ILSCO SGB-4 GROUNDING LUGS <br />NOT TO SCALE <br />CONDUITONE HOLE STEEL STRAP <br />CONDUIT MOUNT BRACKET <br />FLASHING/TILE STRAP <br />1 <br />1 <br />/ <br />2 <br />" <br />SIDE VIEW <br />ROCK-IT 3.0 COUPLING <br />MID CLAMP <br />ROCK-IT <br />COUPLING SHELF <br />TIE PLATE <br />5/16"x1 1/2" <br />HEX FLANGE BOLT <br />300 SERIES SS <br />TILE ROOF TOP <br />ISOMETRIC VIEW <br />ROCK-IT COUPLING <br />MID CLAMP <br />ROCK-IT <br />COUPLING SHELF <br />S 1.0 <br />2 ROCK-IT COUPLING ASSEMBLY <br />NOT TO SCALE <br />LANDSCAPE=MAX 72" (6'-0") <br />PORTRAIT=MAX 48" (4'-0") <br />3" <br />TRUSSES <br />#### AT #### <br />Signed 07/11/2023 <br />525 S Marine St <br />07/28/23