Laserfiche WebLink
97 <br />' <br />- <br />1 <br />1 <br />" <br />58' <br />98 <br />' <br />- <br />9 <br />" <br />60'-10" <br />16 <br />' <br />- <br />2 <br />" <br />3'-5" <br />4'-2" <br />3'-2" <br />DC <br />D <br />IN <br />V <br />AC <br />D <br />BA <br />T <br />MS <br />P <br />M <br />TRANG DO RESIDENCE <br />5402 W LEHNHARDT AVE., SANTA ANA, CA 92704 <br />SIGNED & STAMP BY <br />DATE 10/14/2024 <br />PROJECT ID OPS 034-874 <br />CREATED BY SS <br />CHECKED BY RB <br />SCALE <br />SHEET SIZE <br />11"X 17" <br />ANSI B <br />#REVISION/UPDATE DATE <br />B REVISION 11/04/2024 <br />SHEET INFORMATIONHOMEOWNER INFO <br />SHEET NO. <br />APN NUMBER: 10859132 <br />PV-1 <br />PHONE NO: (714) 548-0899 <br />Luxor Energy, Inc <br />11740 Sterling Ave, Riverside, CA 92503 <br />C10 LICENSE <br />Lic No. #1102673 <br />www.myluxorenergy.com <br />SITE PLAN <br />PROPOSED SITE DIAGRAM SHOWING THE RELATIVE LOCATION OF MAJOR COMPONENTS. <br />1/12" = 1'-0" <br /> ROOF ACCESS POINT: <br />·ROOF ACCESS, PATHWAYS AND SPACING <br />REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE <br />WITH SECTIONS 1205.2.1 THROUGH 1205.3.3. <br />PATHWAYS SHALL BE OVER AREAS CAPABLE OF <br />SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. <br />PATHWAYS SHALL BE LOCATED IN AREAS WITH <br />MINIMAL OBSTRUCTIONS, SUCH AS VENT PIPES, <br />CONDUIT OR MECHANICAL EQUIPMENT. <br />PROTECTION OF EMERGENCY RESPONDERS <br />ALL SHARP EDGES AND FASTENER TIPS <br />SHALL BE COVERED OR CRIMPED OVER <br />TO ELIMINATE SHARP EDGES, TO <br />MINIMIZE RISK OF INJURY TO <br />EMERGENCY RESPONDERS. <br />ALL ROOF MOUNTED CONDUITS, BOXES, <br />AND EQUIPMENT CROSSING PATHWAYS <br />ARE TO BE CLEARLY IDENTIFIED BY A <br />RED/WHITE REFLECTIVE TAPE OR OTHER <br />APPROVED MATERIAL. <br />ROOF ACCESS POINT <br />ROOF #2 <br />(8)JINKO SOLAR JKM425N-54HL4-B MODULES <br />CHIMNEY <br />(N) PV NON FUSED AC DISCONNECT <br />2-STORY <br />HOUSE <br />(N)SOLAREDGE ENERGY HUB SE5700H-US INVERTER <br />PV AC DISCONNECTACD <br />LEGEND <br />FENCE <br />ROOF ACCESS POINT <br />UTILITY METER <br />MAIN SERVICE PANELMSP <br />M <br />INVERTERINV <br />VENT, ATTIC FAN (ROOF <br />OBSTRUCTIONS) <br />PROPERTY LINE <br />(E) PATIO (IT DOES NOT CONTAIN <br />ANY ELECTRICAL EQUIPMENT) <br />(E) DRIVEWAY <br />SOLAREDGE ENERGY BANK <br />BATTERY (10kW)BAT <br />NOTES: BATTERY SHOULD BE INSTALLED 3FEET <br />DISTANCE FROM ANY ENTERING DWELLING UNIT. <br />W LEHNHARDT AVE. <br />(N) SOLAREDGE ENERGY BANK BATTERY <br />(10kW) (BAT-10K1PS0B-02) <br />(N)200A MAIN SERVICE PANEL <br />TIED WITH UTILITY METER <br />(E) FENCE <br />(N) ESS DC DISCONNECT <br />ROOF #1 <br />(7)JINKO SOLAR JKM425N-54HL4-B MODULES <br />ESS DC DISCONNECTDCD <br />(E) CHIMNEY REV_A : 11/04/2024 <br />5402 W Lehnhardt <br />Ave11/25/2024