Laserfiche WebLink
Rev: 7/15/2021 <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />S OL-01 C BC 2019 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />Instructions: Th e licensed contractor of record sh all complete all sections, answer the ten q u estions and <br />sign the certification section below. A copy of th is form shall be attach ed to each of TW O sets of plans , of <br />minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. <br />Project Address: <br />Contractor Company Name: <br />Contractor License Number: <br /> YES NO Are the following applicable to the proposed project? <br />1. W ill th e PV system layou t provid e the required three -foot wide clear access path way s <br />per S ection 605.11 of th e C alifornia Fire C od e, and is this sh own on the roof plan? <br />2. W ill th e PV system be installed on a roof having only one roofing layer with no <br /> overlays? <br />3. W ill the PV array be flu sh mounted to the existing roof so that the plane of th e <br />mod ules (panels) are parallel to th e plane of th e roof? <br />4. W ill th e PV system weig h maximum 4 pounds per square feet or less? <br />5. W ill th e PV system be installed where the modules do not overh ang any roof edg es <br />(such as eaves, gabled ends, rid g es and hips)? <br />6. W ill th e PV system be installed with a space of 2” minimum to 10 ” maximum betwee n <br /> th e u nd erside of mod ule s and the su rface of the roof? <br />7. W ill the PV system be installed without using any ballast system or counter-weight <br /> system? <br />8. W ill th e anchors be installed with a maximum horizontal anch or spacing of 6 feet <br />and is this maximum h orizontal spacing sh own on the plans? <br />9. W ill th e minimum 5/16” lag screws be installed with a minimum of 2 -1/2 inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />10. Are ALL th e stru ctu ral pages of th e plans stamped and signed by a C alifornia <br />licensed professional engineer? (including project specific site plan, PV layou t, <br />anchorage spacing , anchorage details and manufactu rer’s PV support information.) <br />I certify under penalty of perjury under the laws of the State of California that the above is true: <br />Print Name: S ignature: <br />Ph one Number: Date: <br />Email Ad d ress: <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-5800 <br />www.santa-ana.org <br />615 S Mohawk Dr., Santa Ana, CA 92704 <br />ECOSOLAR USA ELECTRIC LLC <br />1045300 <br />Hazzle Dagami <br />(714) 643 8452 <br />hazzle@ecosolarusa.com <br />4/9/2023 <br />615 S M ohawk Dr <br />08/24/23