My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
718 W Tribella Ct - Plan
>
Building
>
ProjectDox
>
T
>
Tribella Crt
>
718 W Tribella Crt
>
718 W Tribella Ct - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:08:24 PM
Creation date
6/1/2025 12:08:05 PM
Metadata
Fields
Template:
Plan
Permit Number
20185356
Full Address
718 W Tribella Crt
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
INFINITY SOLAR <br />TLP ELECTRIC INTEGRATIONS, INC. <br />749 N MAIN ST. <br />ORANGE, CA 92868 <br />PHONE: (714) 880-8089 <br />LIC NO.: C10 - 824287 <br />TIM POLUJANCEWICZ <br />BATTERY NOTES PV.01A <br />[R328.2] EQUIPMENT LISTINGS. ENERGY STORAGE SYSTEMS (ESS) SHALL BE <br />LISTED AND LABELED IN ACCORDANCE WITH UL 9540. <br />[R328.3] INSTALLATION. ESS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURER’S INSTRUCTIONS AND THEIR LISTING. <br />[R328.3.1] SPACING. INDIVIDUAL UNITS SHALL BE SEPARATED FROM EACH <br />OTHER BY NOT LESS THAN 3 FEET (914 MM) EXCEPT WHERE SMALLER <br />SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON <br />LARGE-SCALE FIRE TESTING COMPLYING WITH SECTION 1207.1.5 OF THE <br />CALIFORNIA FIRE CODE. <br />[R328.4] LOCATIONS. ESS SHALL BE INSTALLED ONLY IN THE FOLLOWING <br />LOCATIONS: <br />1. DETACHED GARAGES AND DETACHED ACCESSORY <br /> STRUCTURES. <br />2. ATTACHED GARAGES SEPARATED FROM THE DWELLING UNIT <br /> LIVING SPACE IN ACCORDANCE WITH SECTION R302.6. <br />3. OUTDOORS OR ON THE EXTERIOR SIDE OF EXTERIOR WALLS <br /> LOCATED NOT LESS THAN 3 FEET (914 MM) FROM DOORS AND <br /> WINDOWS DIRECTLY ENTERING THE DWELLING UNIT. <br />4. ENCLOSED UTILITY CLOSETS, BASEMENTS, STORAGE OR UTILITY <br /> SPACES WITHIN DWELLING UNITS WITH FINISHED OR <br /> NONCOMBUSTIBLE WALLS AND CEILINGS. WALLS AND CEILINGS <br /> OF UNFINISHED WOOD-FRAMED CONSTRUCTION SHALL BE <br /> PROVIDED WITH NOT LESS THAN 5/8-INCH (15.9 MM) TYPE X <br /> GYPSUM WALLBOARD. <br />ESS SHALL NOT BE INSTALLED IN SLEEPING ROOMS, OR CLOSETS OR SPACES <br />OPENING DIRECTLY INTO SLEEPING ROOMS OR IN HABITABLE SPACES OF <br />DWELLING UNITS. <br />R328.6 ELECTRICAL INSTALLATION. ESS SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE CEC AND LOCAL ELECTRICAL CODE REQUIREMENTS. INVERTERS <br />SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 1741 OR PROVIDED AS <br />PART OF THE UL 9540 LISTING. SYSTEMS CONNECTED TO THE UTILITY GRID <br />SHALL USE INVERTERS LISTED FOR UTILITY INTERACTION. <br />R328.7 FIRE DETECTION. ROOMS AND AREAS WITHIN DWELLING UNITS, <br />BASEMENTS AND ATTACHED GARAGES IN WHICH ESS ARE INSTALLED SHALL BE <br />PROTECTED BY SMOKE ALARMS IN ACCORDANCE WITH SECTION R314. A HEAT <br />DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS, SHALL BE <br />INSTALLED IN LOCATIONS WITHIN DWELLING UNITS AND ATTACHED GARAGES <br />WHERE SMOKE ALARMS CANNOT BE INSTALLED BASED ON THEIR LISTING. <br />[SFM] ESS INSTALLED IN GROUP R-3 AND TOWNHOMES SHALL COMPLY WITH THE <br />FOLLOWING: <br />1. ROOMS AND AREAS WITHIN DWELLINGS UNITS, SLEEPING UNITS, <br /> BASEMENTS AND ATTACHED GARAGES IN WHICH ESS ARE <br /> INSTALLED SHALL BE PROTECTED BY SMOKE ALARMS IN <br /> ACCORDANCE WITH SECTION R314. <br />2. A LISTED HEAT ALARM INTERCONNECTED TO THE SMOKE <br /> ALARMS SHALL BE INSTALLED IN LOCATIONS WITHIN DWELLING <br /> UNITS, SLEEPING UNITS AND ATTACHED GARAGES WHERE <br /> SMOKE ALARMS CANNOT BE INSTALLED BASED ON THEIR <br /> LISTING. <br />R328.8 PROTECTION FROM IMPACT. ESS INSTALLED IN A LOCATION SUBJECT TO <br />VEHICLE DAMAGE IN ACCORDANCE WITH SECTION R328.8.1 OR R328.8.2 SHALL <br />BE PROVIDED WITH IMPACT PROTECTION IN ACCORDANCE WITH SECTION <br />R328.8.3. <br />R328.8.1 GARAGES. WHERE AN ESS IS INSTALLED IN THE NORMAL DRIVING PATH <br />OF VEHICLE TRAVEL WITHIN A GARAGE, IMPACT PROTECTION COMPLYING WITH <br />SECTION 1207.11.7.3 SHALL BE PROVIDED. THE NORMAL DRIVING PATH IS A <br />SPACE BETWEEN THE GARAGE VEHICLE OPENING AND THE INTERIOR FACE OF <br />THE BACK WALL TO A HEIGHT OF 48 INCHES (1219 MM) ABOVE THE FINISHED <br />FLOOR. THE WIDTH OF THE NORMAL DRIVING PATH SHALL BE EQUAL TO THE <br />WIDTH OF THE GARAGE DOOR OPENING. IMPACT PROTECTION SHALL ALSO BE <br />PROVIDED FOR ESS INSTALLED AT EITHER OF THE FOLLOWING LOCATIONS (SEE <br />FIGURE R328.8.1): <br />1. ON THE INTERIOR FACE OF THE BACK WALL AND LOCATED <br /> WITHIN 36 INCHES (914 MM) TO THE LEFT OR TO THE RIGHT OF <br /> THE NORMAL DRIVING PATH. <br />2. ON THE INTERIOR FACE OF A SIDE WALL AND LOCATED WITHIN <br /> 24 INCHES (609 MM) FROM THE BACK WALL AND 36 INCHES <br /> (914 MM) OF THE NORMAL DRIVING PATH. <br />EXCEPTION: WHERE THE CLEAR HEIGHT OF THE VEHICLE GARAGE OPENING IS 7 <br />FEET 6 INCHES (2286 MM) OR LESS, ESS INSTALLED NOT LESS THAN 36 INCHES <br />(914 MM) ABOVE FINISHED FLOOR ARE NOT SUBJECT TO VEHICLE IMPACT <br />PROTECTION REQUIREMENTS. <br />R328.8.2 OTHER LOCATIONS SUBJECT TO VEHICLE IMPACT. WHERE AN ESS IS <br />INSTALLED IN A LOCATION OTHER THAN AS DEFINED IN SECTION R328.8.1, AND <br />IS SUBJECT TO VEHICLE DAMAGE, IMPACT PROTECTION SHALL BE PROVIDED IN <br />ACCORDANCE WITH SECTION R328.8.3. <br />BATTERY INSTALLATION REQUIREMENTS <br />R328.8.3 IMPACT PROTECTION OPTIONS. WHERE ESS IS REQUIRED TO BE <br />PROTECTED FROM IMPACT IN ACCORDANCE WITH SECTION R328.8.1 OR <br />R328.8.2, SUCH PROTECTION SHALL COMPLY WITH ONE OF THE FOLLOWING: <br />1. BOLLARDS CONSTRUCTED IN ACCORDANCE WITH ONE OF THE <br /> FOLLOWING: <br />1.1. MINIMUM 48 INCHES (1219 MM) IN LENGTH BY 3 INCHES (76 <br /> MM) IN DIAMETER SCHEDULE 80 STEEL PIPE EMBEDDED IN A <br /> CONCRETE PIER NOT LESS THAN 12 INCHES (304 MM) DEEP AND <br /> 6 INCHES (152 MM) IN DIAMETER, WITH AT LEAST 36 INCHES (914 <br /> MM) OF PIPE EXPOSED, FILLED WITH CONCRETE AND SPACED <br /> AT A MAXIMUM INTERVAL OF 5 FEET (1524 MM). EACH BOLLARD <br /> SHALL BE LOCATED NOT LESS THAN 6 INCHES (152 MM) FROM <br /> AN ESS. <br />1.2. MINIMUM 36 INCHES (914 MM) IN HEIGHT BY 3 INCHES (76 MM) <br /> IN DIAMETER SCHEDULE 80 STEEL PIPE FULLY WELDED TO A <br /> MINIMUM 8-INCH (203 MM) BY 1/4-INCH (6.4 MM) THICK STEEL <br /> PLATE AND BOLTED TO A CONCRETE FLOOR BY MEANS OF 41/2 <br /> INCH (13 MM) CONCRETE ANCHORS WITH 3-INCH (76 MM) <br /> MINIMUM EMBEDMENT. SPACING SHALL BE NOT GREATER THAN <br /> 60 INCHES (1524 MM), AND EACH BOLLARD SHALL BE LOCATED <br /> NOT LESS THAN 6 INCHES (152 MM) FROM THE ESS. <br />1.3. PRE-MANUFACTURED STEEL PIPE BOLLARDS SHALL BE FILLED <br /> WITH CONCRETE AND ANCHORED IN ACCORDANCE WITH THE <br /> MANUFACTURER’S INSTALLATION INSTRUCTIONS, WITH SPACING <br /> NOT GREATER THAN 60 INCHES (1524 MM), AND EACH <br /> BOLLARD SHALL BE LOCATED NOT LESS THAN 6 INCHES (152 <br /> MM) FROM THE ESS. <br />2. WHEEL BARRIERS CONSTRUCTED IN ACCORDANCE WITH ONE <br /> OF THE FOLLOWING: <br />2.1. FOUR INCHES (102 MM) IN HEIGHT BY 5 INCHES (127 MM) IN <br /> WIDTH BY 70 INCHES (1778 MM) IN LENGTH WHEEL BARRIER <br /> MADE OF CONCRETE OR POLYMER, ANCHORED TO THE <br /> CONCRETE FLOOR NOT LESS THAN EVERY 36 INCHES (914 MM) <br /> AND LOCATED NOT LESS THAN 54 INCHES (1372 MM) FROM THE <br /> ESS. MINIMUM 31/2-INCH (89 MM) DIAMETER CONCRETE <br /> ANCHORS WITH A 3-INCH (76 MM) EMBEDMENT PER BARRIER <br /> SHALL BE USED. SPACING BETWEEN BARRIERS SHALL BE NO <br /> GREATER THAN 36 INCHES (914 MM). <br />2.2. PRE-MANUFACTURED WHEEL BARRIERS SHALL BE ANCHORED IN <br /> ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION <br /> INSTRUCTIONS. <br />3. APPROVED METHOD DESIGNED TO RESIST A 2000-LB. (8899 <br /> NEWTONS) IMPACT IN THE DIRECTION OF TRAVEL AT 24 INCHES <br /> (608 MM) ABOVE GRADE. <br />DRAWN BY: <br />PAPER: 11X17 (ANSI B)DATE: <br />DESIGN LEAD: <br />DESIGNED BY SOLAR DEPLOYED, LLC. <br />931 10TH ST #114, MODESTO, CA 95354 <br />209-671-2001 | HELLO@SOLARDEPLOYED.COM <br />SIGNATURE: <br />CHECKED BY: <br />1/29/2025 <br />A.R. <br />D.A.A.B. <br />SHEET NAME: <br />NEW PV SYSTEM <br /> 5.040 kW DC (STC-DC) | 4.719 kW (CEC-AC) <br />GRAHAM BERGER <br />718 W TRIBELLA CT, <br />SANTA ANA, CA 92703 <br />APN: 19835227 <br />SHEET NO.: <br />ENGINEER OF RECORD <br />ADDITIONAL NOTES <br />718 W Tribella Ct <br />3/17/2025
The URL can be used to link to this page
Your browser does not support the video tag.