My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
718 W Tribella Ct - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tribella Crt
>
718 W Tribella Crt
>
718 W Tribella Ct - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:08:24 PM
Creation date
6/1/2025 12:08:05 PM
Metadata
Fields
Template:
Plan
Permit Number
20185356
Full Address
718 W Tribella Crt
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PANASONIC <br />EVHB-I7 [240V] <br />[240V] [SI1-SB] <br />WITH DC DISCONNECT <br />DC <br />INVERTER 1 <br />AC <br />PANASONIC <br />EVHB-I7-X15 <br />15kWh <br />PV AC DISCONNECT <br />60A NON-FUSED <br />240V, NEMA 3R <br />VISIBLE/LOCKABLE <br />LABELLED ACD <br />03 03 <br />TO UTILITY GRID <br />(UNDERGROUND) <br />M <br /> 200A <br />(N)40A <br />(E) 225A MAIN SERVICE PANEL <br />240/120 V 1Ø, 3W <br />BUS RATING: 225A <br />MCB RATING: 200A <br />INTERCONNECTION STRATEGY: <br />LOAD SIDE 705.12(B)(3)(2) <br />MAX. BACKFEED CURRENT CALC: <br />225A X 1.2 - 200A = 70A <br />METER NUMBER: <br />222014-393842 <br />(E) GROUNDING <br />ELECTRODE <br />PV AC DISCONNECT <br />60A NON-FUSED <br />240V, NEMA 3R <br />VISIBLE/LOCKABLE <br />LABELLED ACD <br />03 <br />6 <br />6 <br />STRING 1-2 <br />INVERTER 1 <br />S1.2 <br />S1.1 <br />01 <br />02 <br />JU <br />N <br />C <br />T <br />I <br />O <br />N <br /> <br />B <br />O <br />X <br />NE <br />M <br /> <br />3 <br />R <br />, <br /> <br />U <br />L <br /> <br />L <br />I <br />S <br />T <br />E <br />D <br />1.1 <br />1.2 <br />LOAD SHIFT <br />ONLY INFINITY SOLAR <br />TLP ELECTRIC INTEGRATIONS, INC. <br />749 N MAIN ST. <br />ORANGE, CA 92868 <br />PHONE: (714) 880-8089 <br />LIC NO.: C10 - 824287 <br />TIM POLUJANCEWICZ <br />(12) PANASONIC <br />EVPV420HK2 <br />RATED POWER (PMAX) (W)420W <br />RATED POWER (PTC) (W)403.3W <br />SHORT CIRCUIT CURRENT (ISC) (A) 10.74A <br />MAXIMUM POWER CURRENT (IMP) (A) 9.96A <br />OPEN CIRCUIT VOLTAGE (VOC) (V) 48.8V <br />MAXIMUM POWER VOLATGE (VMP) (V) 42.2V <br />TEMP. COEFF. OF VOC (%/C)-0.235 %/C <br />SYSTEM SUMMARY <br />SYSTEM SIZE (STC-DC): 5.040 kW <br />SYSTEM SIZE (CEC-AC): 4.719 kW <br />INVERTER RATED POWER (AC): 7.60 kW <br />718 W TRIBELLA CT, SANTA ANA, CA 92703 <br />PV SYSTEM ELECTRICAL SPECIFICATIONS AND CALCULATIONS <br />INVERTER SPECS <br />(6) AP SMART RSD-D-15 <br />RATED INPUT (W) 2000W <br />RATED INPUT ISC (A) 15A <br />MAX DC (V)80V <br />RATED OUTPUT (A) 15A <br />WEIGHTED EFFICIENCY N/A% <br />OPTIMIZER/RSD SPECS <br />OVERCURRENT CALCULATION <br />COMBINED INVERTER OUTPUT: 31.70A <br />MAX PV CURRENT (125%):39.63A <br />(1) PANASONIC EVHB-I7 [240V] <br />[240V] [SI1-SB] <br />RATED POWER (W) 7600W <br />MAX INPUT (A) 16A <br />MAX INPUT (V) 550V <br />MAX OUTPUT (A) 31.7A <br />MAX OUTPUT 125% (A)39.63A <br />MAX OCPD (A) 40A <br />EFFICIENCY (CEC) 0.975% <br />AP SMART RSD-D-15 PROVIDE <br />MODULE-LEVEL RAPID SHUTDOWN & ARE <br />690.12 COMPLIANT. <br />MODULE SPECS <br />ID CONDUCTOR GROUND CONDUIT <br />CURRENT CARRYING <br />CONDUCTORS <br />IN CONDUIT <br />CONT. <br />CURRENT <br />125% MAX. <br />CURRENT <br />MIN. <br />OCPD <br />TEMP. <br />CORR. <br />FACTOR <br />CONDUIT <br />FILL <br />FACTOR <br />BASE AMP. <br />@ 90°C <br />DERATED <br />90°C AMP. <br />TERMINAL <br />TEMP. <br />RATING <br />TERMINAL <br />AMP <br />RATING <br />CONDUIT AND WIRE SCHEDULE <br />01 10 AWG PV WIRE, Cu 6 AWG BARE, Cu FREE AIR N/A 15A 18.75A N/A 0.94 (31°C)1 55A 51.70A 75°C 55A <br />02 10 AWG THWN-2, Cu 8 AWG, THWN-2, Cu 0.75" EMT 4 (2 PER STRING)15A 18.75A N/A 0.94 (31°C)0.8 40A 30.08A 75°C 35A <br />03 8 AWG THWN-2, Cu 8 AWG, THWN-2, Cu 0.75" EMT 3 31.70A 39.63A 40A 0.94 (31°C)1 55A 51.70A 75°C 50A <br />WIRE TABLE AND CONDUIT NOTES <br />DRAWN BY: <br />PAPER: 11X17 (ANSI B)DATE: <br />DESIGN LEAD: <br />DESIGNED BY SOLAR DEPLOYED, LLC. <br />931 10TH ST #114, MODESTO, CA 95354 <br />209-671-2001 | HELLO@SOLARDEPLOYED.COM <br />SIGNATURE: <br />CHECKED BY: <br />1/29/2025 <br />A.R. <br />D.A.A.B. <br />SHEET NAME: <br />NEW PV SYSTEM <br /> 5.040 kW DC (STC-DC) | 4.719 kW (CEC-AC) <br />GRAHAM BERGER <br />718 W TRIBELLA CT, <br />SANTA ANA, CA 92703 <br />APN: 19835227 <br />SHEET NO.: <br />ENGINEER OF RECORD <br />LINE DIAGRAM PV.04 <br />A. ROOFTOP TEMPERATURE CORRECTION <br />FACTOR REFLECTS REQUIRED MIN. 7/8" <br />CONDUIT HEIGHT FROM ROOF. <br />B. ALL CONDUCTORS SHALL BE COPPER AND <br />RATED A MINIMUM OF 90°C; ALL TERMINALS <br />SHALL BE RATED A MINIMUM OF 75°C. <br />C. ALL NEW WIRES ARE THWN-2 COPPER <br />UNLESS OTHERWISE NOTED. <br />D. NEUTRAL WIRE SIZE TO MATCH <br />CONDUCTOR RATING WHERE NEUTRAL IS <br />APPLICABLE. <br />SEE DESIGN CALCULATIONS PAGE FOR <br />ADDITIONAL NOTES AND DETAILS <br />WEATHER STATION <br />TUSTIN MCAF <br />EXTREME LOW TEMP.:2°C <br />2% HIGH TEMP. 31°C <br />TEMP. DERATE FACTOR: 0.94 <br />BATTERY BACKUP NOTES <br />A. PRODUCERS STORAGE DEVICE(S) WILL NOT CAUSE THE HOST LOAD TO <br />EXCEED ITS NORMAL PEAK DEMAND. NORMAL PEAK DEMAND IS DEFINED <br />AS THE HIGHEST AMOUNT OF POWER REQUIRED FROM THE DISTRIBUTION <br />SYSTEM BY PRODUCERS COMPLETE FACILITIES WITHOUT THE INFLUENCE <br />OR USE OF THE ENERGY STORAGE DEVICE(S). <br />718 W Tribella Ct <br />3/17/2025
The URL can be used to link to this page
Your browser does not support the video tag.