My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
718 W Tribella Ct - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tribella Crt
>
718 W Tribella Crt
>
718 W Tribella Ct - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:08:24 PM
Creation date
6/1/2025 12:08:05 PM
Metadata
Fields
Template:
Plan
Permit Number
20185356
Full Address
718 W Tribella Crt
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(12) PANASONIC <br />EVPV420HK2 <br />RATED POWER (PMAX) (W)420W <br />RATED POWER (PTC) (W)403.3W <br />SHORT CIRCUIT CURRENT (ISC) (A) 10.74A <br />MAXIMUM POWER CURRENT (IMP) (A) 9.96A <br />OPEN CIRCUIT VOLTAGE (VOC) (V) 48.8V <br />MAXIMUM POWER VOLATGE (VMP) (V) 42.2V <br />TEMP. COEFF. OF VOC (%/C)-0.235 %/C <br />SYSTEM SUMMARY <br />SYSTEM SIZE (STC-DC): 5.040 kW <br />SYSTEM SIZE (CEC-AC): 4.719 kW <br />INVERTER RATED POWER (AC): 7.60 kW <br />718 W TRIBELLA CT, SANTA ANA, CA 92703 <br />PV SYSTEM ELECTRICAL SPECIFICATIONS AND CALCULATIONS <br />INVERTER SPECS <br />(6) AP SMART RSD-D-15 <br />RATED INPUT (W) 2000W <br />RATED INPUT ISC (A) 15A <br />MAX DC (V)80V <br />RATED OUTPUT (A) 15A <br />WEIGHTED EFFICIENCY N/A% <br />OPTIMIZER/RSD SPECS <br />OVERCURRENT CALCULATION <br />COMBINED INVERTER OUTPUT: 31.70A <br />MAX PV CURRENT (125%):39.63A <br />(1) PANASONIC EVHB-I7 [240V] <br />[240V] [SI1-SB] <br />RATED POWER (W) 7600W <br />MAX INPUT (A) 16A <br />MAX INPUT (V) 550V <br />MAX OUTPUT (A) 31.7A <br />MAX OUTPUT 125% (A)39.63A <br />MAX OCPD (A) 40A <br />EFFICIENCY (CEC) 0.975% <br />AP SMART RSD-D-15 PROVIDE <br />MODULE-LEVEL RAPID SHUTDOWN & ARE <br />690.12 COMPLIANT. <br />MODULE SPECS <br />ID CONDUCTOR GROUND CONDUIT <br />CURRENT CARRYING <br />CONDUCTORS <br />IN CONDUIT <br />CONT. <br />CURRENT <br />125% MAX. <br />CURRENT <br />MIN. <br />OCPD <br />TEMP. <br />CORR. <br />FACTOR <br />CONDUIT <br />FILL <br />FACTOR <br />BASE AMP. <br />@ 90°C <br />DERATED <br />90°C AMP. <br />TERMINAL <br />TEMP. <br />RATING <br />TERMINAL <br />AMP <br />RATING <br />WEATHER STATION: TUSTIN MCAF [ASHRAE EXTREME LOW TEMP.:2°C | ASHRAE 2% HIGH TEMP. 31°C] <br />ROOFTOP TEMPERATURE CORRECTION FACTOR REFLECTS REQUIRED MIN. 7/8" CONDUIT HEIGHT FROM ROOF <br />ALL CONDUCTORS SHALL BE COPPER AND RATED A MINIMUM OF 90°C; ALL TERMINALS SHALL BE RATED A MINIMUM OF 75°C.CONDUIT AND WIRE SCHEDULE <br />01 10 AWG PV WIRE, Cu 6 AWG BARE, Cu FREE AIR N/A 15A 18.75A N/A 0.94 (31°C)1 55A 51.70A 75°C 55A <br />02 10 AWG THWN-2, Cu 8 AWG, THWN-2, Cu 0.75" EMT 4 (2 PER STRING)15A 18.75A N/A 0.94 (31°C)0.8 40A 30.08A 75°C 35A <br />03 8 AWG THWN-2, Cu 8 AWG, THWN-2, Cu 0.75" EMT 3 31.70A 39.63A 40A 0.94 (31°C)1 55A 51.70A 75°C 50A <br />INFINITY SOLAR <br />TLP ELECTRIC INTEGRATIONS, INC. <br />749 N MAIN ST. <br />ORANGE, CA 92868 <br />PHONE: (714) 880-8089 <br />LIC NO.: C10 - 824287 <br />TIM POLUJANCEWICZ <br />ELECTRICAL & CONDUIT NOTES <br />A. MAIN PANEL UPGRADES. A TYPE 1 OR TYPE 2 SURGE PROTECTION DEVICE <br />SHALL BE INSTALLED FOR THE NEW MSP EITHER AS AN INTEGRAL PART OF THE <br />SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO. <br />[CEC 230.67] <br />B. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR <br />PURPOSE. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON <br />MINIMUM CODE REQUIREMENT AND ARE NOT MEANT TO LIMIT UP-SIZING AS <br />REQUIRED BY FIELD CONDITIONS. <br />C. CONDUIT RACEWAYS SHALL BE PROVIDED WITH EXPANSION FITTINGS TO <br />COMPENSATE FOR THERMAL EXPANSION AND CONTRACTION. [CEC 110 (B) AND <br />110.14 (D)] <br />D. PROVIDE PULL BOXES AND/OR EXPANSION OR DEFLECTION FITTINGS FOR <br />THE ROOFTOP CONDUITS TO ACCOMMODATE THERMAL EXPANSION AND <br />CONTRACTION. [CEC 300.7(B)] <br />E. ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE INSTALLED A <br />MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR <br />CABLE OF 7/8" IN. (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). <br />F. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND <br />IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. [CEC <br />690.31(C) THROUGH (F), 310.10(D)] <br />G. EXPOSED CONDUCTORS WITHIN THE PV ARRAY SHALL BE PV WIRE/CABLE, <br />OR TYPE USE-2, OR TYPE RHW-2 (UL 4703 & 854 LISTED) [CEC 690.31(C)(1)] <br />H. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN TIGHT AND <br />APPROVED FOR USE IN WET LOCATIONS. (CEC 314.15) <br />I. DC WIRING INSIDE A BUILDING MUST BE IN METAL RACEWAYS, METAL-CLAD <br />CABLE, OR METAL ENCLOSURES. [CEC 690.31(D)] <br />J. EQUIPMENT GROUNDING CONDUCTOR (EGC) SMALLER THAN #6-AWG SHALL <br />BE PROTECTED FROM PHYSICAL DAMAGE BY AN IDENTIFIED RACEWAY OR <br />CABLE ARMOR, UNLESS INSTALLED WITHIN HOLLOW SPACES OF THE FRAMING <br />MEMBERS OF BUILDINGS OR STRUCTURES AND WHERE NOT SUBJECT TO <br />PHYSICAL DAMAGE. [CEC 250.120(C)] <br />K. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE <br />NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED. [CEC 300.4] <br />L. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE <br />REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY <br />FIELD CONDITIONS. <br />ADDITIONAL BATTERY STORAGE NOTES <br />PRODUCERS STORAGE DEVICE(S) WILL NOT CAUSE THE HOST LOAD TO EXCEED <br />ITS NORMAL PEAK DEMAND. NORMAL PEAK DEMAND IS DEFINED AS THE <br />HIGHEST AMOUNT OF POWER REQUIRED FROM THE DISTRIBUTION SYSTEM BY <br />PRODUCERS COMPLETE FACILITIES WITHOUT THE INFLUENCE OR USE OF THE <br />ENERGY STORAGE DEVICE(S). <br />DESIGN CALCULATIONS PV.05 <br />ADDITIONAL NOTES <br />DRAWN BY: <br />PAPER: 11X17 (ANSI B)DATE: <br />DESIGN LEAD: <br />DESIGNED BY SOLAR DEPLOYED, LLC. <br />931 10TH ST #114, MODESTO, CA 95354 <br />209-671-2001 | HELLO@SOLARDEPLOYED.COM <br />SIGNATURE: <br />CHECKED BY: <br />1/29/2025 <br />A.R. <br />D.A.A.B. <br />SHEET NAME: <br />NEW PV SYSTEM <br /> 5.040 kW DC (STC-DC) | 4.719 kW (CEC-AC) <br />GRAHAM BERGER <br />718 W TRIBELLA CT, <br />SANTA ANA, CA 92703 <br />APN: 19835227 <br />SHEET NO.: <br />ENGINEER OF RECORD <br />718 W Tribella Ct <br />3/17/2025
The URL can be used to link to this page
Your browser does not support the video tag.