Laserfiche WebLink
MAIN SERVICE PANEL <br />GROUNDING ELECTRODE & <br />AUXILLARY GROUNDING <br />ELECTRODE AS NEEDED PER <br />CEC 690.47 (6 FEET APART) <br />L <br />LL <br />L <br />GN <br />D N <br /> A TOP FED <br />ME <br />T <br />E <br />R <br /> <br /># <br />100A/2P <br />22 <br />2 <br />0 <br />1 <br />3 <br />- <br />5 <br />0 <br />0 <br />9 <br />3 <br />4 <br />(E)100 <br />(E) <br />70A/2P <br />(N) <br />GN <br />D N <br />(N) 125A <br />LOAD CENTER <br />NEMA-3R <br />3 <br />(N) <br />30A/2P <br />(N)70A/2P <br />THWN-2 <br />3-#4 <br />1-#8 GRND <br />1" EMT CONDUIT <br />AFCI PROTECTION <br />WILL BE PROVIDED <br />FOR 15A AND 20A <br />BREAKERS THAT ARE <br />RELOCATED MORE <br />THAN 6' FROM THE <br />ORIGINAL BREAKER <br />SOURCE <br />TRANSFER <br />(E) <br />MSP <br />LOADS <br />(N) 30A <br />VISIBLY OPEN, <br />LOCKABLE, <br />AC DISCONNECT <br />240V NEMA-3R <br />G <br />3 <br />enphase <br />ENERGY <br />CELLULAR <br />REVENUE-GRADE <br />PRODUCTION METERING <br />FACTORY INSTALLED <br />MODEL #: <br />X-IQ-AM1-240-4C <br />CELLMODEM-M1-06 <br />C E L L <br />MODEM <br />20A/2P <br />20A/2P <br />SPARE <br />SPARE <br />15A <br />Enphase IQ Gateway <br />(N) 125A ENPHASE IQ <br />COMBINER 4C NEMA-3R <br />X-IQ-AM1-240-4C <br />[CRD-PCS NEM] <br />EACH WITH AN <br />ENPHASE <br />MICROINVERTER <br />AC J-BOX <br />G <br />1 STRING OF <br />MODULES7 <br />EACH WITH AN <br />ENPHASE <br />MICROINVERTER <br />AC J-BOX <br />G <br />1 STRING OF <br />MODULES7 <br />1 <br />1 <br />2 <br />2 <br />E7 <br />SHEET NUMBER: <br />SE <br />M <br />P <br />E <br />R <br /> <br />S <br />O <br />L <br />A <br />R <br />I <br />S <br />1 <br />8 <br />0 <br />5 <br /> <br />J <br />O <br />H <br />N <br /> <br />T <br />O <br />W <br />E <br />R <br />S <br /> <br />A <br />V <br />E <br />EL <br /> <br />C <br />A <br />J <br />O <br />N <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />0 <br />2 <br />0 <br />C- <br />1 <br />0 <br /> <br />L <br />I <br />C <br /> <br /># <br /> <br />9 <br />7 <br />8 <br />1 <br />5 <br />2 <br />Li <br />c <br />. <br /> <br />H <br />o <br />l <br />d <br />e <br />r <br /> <br />D <br />i <br />g <br />i <br />t <br />a <br />l <br />l <br />y <br /> <br />S <br />t <br />a <br />m <br />p <br />e <br />d <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />: <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br />DRAWN BY: <br />DATE: <br />(DC) kW: <br />PROJECT #: <br />Jo <br />h <br />n <br /> <br />A <br />l <br />m <br />o <br />n <br />d <br />ENPH DESIGN <br />01-02-2023 <br />79275 <br />5.60 <br />PE <br />T <br />E <br /> <br />M <br /> <br />A <br />B <br />A <br />S <br />C <br />A <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />61 <br />3 <br /> <br />W <br /> <br />B <br />E <br />L <br />L <br /> <br />A <br />V <br />E <br />(7 <br />1 <br />4 <br />) <br /> <br />8 <br />6 <br />5 <br />- <br />0 <br />4 <br />6 <br />6 <br />41 <br />0 <br />1 <br />9 <br />5 <br />0 <br />6 <br />SO <br />L <br />A <br />R <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br />SY <br />S <br />T <br />E <br />M <br /> <br />S <br />I <br />Z <br />E <br />: <br />5. <br />6 <br />0 <br /> <br />k <br />W <br /> <br />D <br />C <br /> <br />P <br />V <br />UTILITY COMPANY: MSP VOLTAGE: <br />MSP GROUND:SERV. TYPE: <br />SERVICE INFO <br />SCE 120/240 <br />UNDERGROUND (E) UFER <br />BUS <br />BAR <br />MAIN <br />BREAKER <br />MAX <br />PV OUTPUT <br />CURRENT <br />120% RULE <br />FOR LC <br />( 125 x 1.2 ) - 70 = 80 <br />QTY: <br />INVERTER: <br />WATTAGE:VOLTAGE:CEC EFF: <br />INVERTER SPECS <br />IQ8M-72-2-US <br />325240 97% <br />14 2% Avg. 1" MIN <br />ASHRAE AMBIENT TEMPERATURE SPECS <br />° C ° C <br />High Temp EXTREMEDISTANCE <br />ABOVE ROOF <br />NO TEMP ADDER <br />PER 310.15(B)(3)(C) 31 2 <br />WIRE <br />QTY <br />WIRE <br />TAG #CONDUIT WIRE TYPE INVERTER <br />QTY:NOC: CONDUIT <br />FILL: <br />TEMP <br />RATING: <br />WIRE <br />AMP <br />TEMP <br />DE-RATE: <br />A <br />WIRE <br />OCP: <br />GRND <br />SIZE <br />GRND WIRE <br />TYPEENPHASE TRUNK CABLE <br />INCLUDES #12 GROUND <br />WIRE <br />GAUGE: <br />x x = <br />TERMINAL <br />75°C RATING: <br />x x 1.25 <br />NEC: <br />= <br />STRING <br />AMPS <br />A <br />Ax x = x x 1.25 = A <br />Ax x = x x 1.25 = A <br />1 AIR 2 #12 TRUNK CABLE 90°C 30 0.96 1 28.8 25A 7 1.35 11.81 #6 SBC <br />2 3/4" EMT 2 #10 THWN-2 90°C 40 0.96 1 38.4 35A 7 1.35 11.81 #8 THWN-2 <br />3 3/4"EMT 3 #10 THWN-2 90°C 40 0.96 1 38.4 35A 14 1.35 23.63 #8 THWN-2 <br />WIRE OCP FOR WIRES CONNECTED <br />TO BREAKERS TO BE GREATER THAN <br />THE SIZE OF THE BREAKER. <br />EQUIPMENT TERMINALS ARE RATED <br />AT 75°C. STRING AMPERAGE NOT TO <br />EXCEED THE 75°C RATING OF THE <br />WIRE THAT IS ATTACHED TO THE <br />TERMINALS. <br />NOTES <br />NEW PV CONDUIT TO HIDDEN FROM <br />VIEW. CONDUIT TO BE PAINTED TO <br />MATCH THE EXISTING SURFACE. <br />CONDUIT RUN TO BE DETERMINED BY <br />INSTALLER. <br />QTY:MODULE TYPE: WATTAGE: <br />Isc:Imp: <br />MODULE SPECS <br />Voc:Vpmax: <br /> 14Q.PEAK ML-G10+ 400 400 <br />45.3V 37.13V11.14A 10.77A <br />WARNING: <br />THIS EQUIPMENT FED BY MULTIPLE SOURCES. <br />TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE, <br />SHALL NOT EXCEED AMPACITY OF BUSBAR. <br />70A SUB BREAKER <br />=70 TOTAL AMPS <br />70A <100A MAIN AND <br />BUS RATING <br />INTERCONNECTION METHOD PER 705.12(B)(3)(2): <br />WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER <br />ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT <br />CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT <br />CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING <br />THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. <br />INTERCONNECTION METHOD PER 705.12(B)(3)(3): <br />THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT DEVICES ON <br />PANELBOARDS, BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF <br />THE OVERCURRENT DEVICE PROTECTING THE BUSBAR, SHALL NOT EXCEED <br />THE AMPACITY OF THE BUSBAR. THE RATING OF THE OVERCURRENT DEVICE <br />PROTECTING THE BUSBAR SHALL NOT EXCEED THE RATING OF THE BUSBAR. <br />613 W Bell Ave <br />03/20/23