CALGREEN 2022 COMPLIANCE SCHEDULE <br />SECTION REQUIREMENT PROJECT-SPECIFIC INFORMATION RESPONSIBILITY DOCUMENTATION <br />VERIFICATION <br />5.1 <br />5.106.1 <br />5.106.4.1.1 <br />5.106.4.1.2 <br />5.106.8 <br />5.106.10 <br />5.3 <br />5.303.1.1 <br />5.303.3.1 <br />5.303.6 <br />5.304.1 <br />5.4 <br />5.407.2.1 Moisture control, sprinklers –Design and maintain <br />landscape irrigation systems to prevent spray on structures. <br />5.407.2.2.1 <br />5.408.1 Specification Section 017419 Contractor <br />Construction Waste <br />Management Plan + <br />waste/recycling weight tickets <br />and receipts <br />Specification Section 017419 Contractor 5.408.1.1 <br />5.408.3 <br />5.410.1 <br />5.410.2 <br />SECTION REQUIREMENT PROJECT-SPECIFIC INFORMATION RESPONSIBILITY DOCUMENTATION <br />VERIFICATION <br />5.5 <br />5.503.1 Fireplaces –Install only direct-vent sealed-combustion gas or <br />sealed wood-burning fireplaces, or a sealed wood stove or <br />pellet stove. Wood stoves and pellet stoves shall comply with <br />U.S. EPA NSPS emission limits. <br />Covering of duct openings and protection of mechanical <br />equipment during construction –All duct and air distribution <br />component openings shall be covered with tape, plastic, <br />and/or sheet metal during storage and rough installation until <br />final startup in order to reduce the amount of dust and debris <br />which may collect in the system. <br />Contractor / <br />Installer <br />Adhesives, sealants and caulks shall comply with V.O.C. <br />limits listed in Tables 5.504.4.1 + 5.504.2 <br />Refer to Interior Finish Schedule and <br />Specification Section 079200 <br />Paints and coatings shall comply with V.O.C. limits listed in <br />Table 5.504.4.3 <br />Refer to Interior Finish Schedule and <br />Specification Section 099100 <br />Carpet systems (including carpet cushion) shall meet the <br />testing and product requirements of Carpet and Rug <br />Institute's Green Label Plus Program. <br />Refer to Interior Finish Schedule and <br />Specification Section 096816 and/or 096813 <br />Refer to Interior Finish Schedule and <br />Specification Sections 062000 + 064100 <br />Composite wood products –Hardwood plywood, <br />particleboard, and medium density fiberboard shall comply <br />with formaldehyde emission limits specified in Table 5.504.4.5. <br />No additional <br />documentation required <br />5.504.3 <br />5.504.4.1 <br />5.504.4.3 <br />5.504.4.4 <br />5.504.4.5 <br />Contractor / <br />Installer <br />Contractor / <br />Installer <br />Contractor / <br />Installer <br />Contractor / <br />Installer <br />Product data for <br />installed materials <br />Product data for <br />installed materials <br />Product data for <br />installed materials <br />Product data and/or <br />certifications; <br />chain of custody certifications <br />Refer to Interior Finish Schedule and <br />Specification Sections 096513, 096516, <br />096519, and 096566. <br />5.504.4.6 Contractor / <br />Installer <br />Product data for <br />installed materials <br />Air filters –Install air filtration media with a minimum MERV <br />rating of 13 for outside and return air. <br />5.504.5.3 Contractor / <br />Installer <br />Product data and location <br />of installed filters <br />Environmental Tobacco Smoke control –At designated <br />outdoor smoking areas, post signage prohibiting smoking <br />within 25' of building entries, outdoor air intakes, and operable <br />windows; or comply with local or applicable ordinance. <br />5.504.7 <br />Indoor moisture control –Buildings shall meet or exceed <br />provisions of California Building Code, CCR, Title 24, Part 2, <br />Section 1202, and Chapter 14. <br />5.505.1 Jurisdiction No additional <br />documentation required <br />5.507.4.1 <br />Interior sound transmission –Wall and floor-ceiling <br />assemblies separating tenant spaces from other tenant <br />spaces or public spaces shall have an STC of at least 40. <br />5.507.4.3 <br />5.508.2 <br />5.504.1 Limit use of permanent HVAC system during construction <br />to condition the building within the required temperature range <br />for material and equipment installation. If the HVAC system is <br />used during construction, use return air filters with a Minimum <br />Efficiency Reporting Value (MERV) of 8, or an average <br />efficiency of 30%; and replace all filters prior to occupancy. <br />Refer to notes on mechanical plans.Contractor / <br />Installer <br />No additional <br />documentation required <br />Refer to notes on mechanical plans. <br />Refer to notes on mechanical plans. <br />5.507.4.1.1 Noise exposure where noise contours not readily <br />available –Buildings exposed to a noise level of 65 dB Leq-1- <br />hr during any hour of operation shall have exterior wall and <br />roof-ceiling assemblies exposed to the noise source meeting <br />a minimum composite STC rating of 45, with exterior <br />windows of a minimum STC of 40. <br />5.106.5.3 <br />5.303.3.2 <br />Showerheads shall have a maximum flow rate of 1.8 <br />gal/min at 80 psi. Showerheads shall be certified to the <br />performance criteria of the U.S. EPA Watersense <br />Specification for Showerheads. <br />5.303.3.3.1 <br />5.303.3.3.2 Multiple showerheads serving one shower shall <br />have a combined maximum flow rate of 1.8 gal/min <br />at 80 psi. Or, the shower shall be designed to allow <br />only one showerhead to be in operation at a time. <br />5.407.1 <br />Outside air delivery for mechanically or naturally ventilated <br />spaces in buildings –Meet the minimum requirements of <br />Section 120.1 (Requirements For Ventilation) of the <br />California Energy Code, or applicable local code, whichever <br />is more stringent, and Division 1, Chapter 4 of CCR, Title 8. <br />5.506.1 Jurisdiction No additional <br />documentation required <br />CO2 monitoring –For buildings or additions equipped with <br />demand control ventilation, CO2 sensors and ventilation <br />controls shall be specified and installed per California Energy <br />Code, Section 120.1(c)(4). <br />5.506.2 <br />5.507.4 Jurisdiction No additional <br />documentation required <br />Acoustical control –Employ building assemblies and <br />components with Sound Transmission Class (STC) values <br />determined in accordance with ASTM E90 and ASTM E413 <br />or Outdoor-Indoor Sound Transmission Class (OITC) <br />determined in accordance with ASTM E 1332. <br />Performance method –For buildings located as defined in <br />Section 5.507.4.1 or 5.507.4.1.1, wall and roof-ceiling <br />assemblies exposed to the noise source making up the <br />building or addition envelope or altered envelope shall be <br />constructed to provide an interior noise environment <br />attributable to exterior sources that does not exceed an <br />hourly equivalent noise level of 50dBA in occupied areas <br />during any hour of operation. <br />5.507.4.2 <br />Site features –Exterior features such as sound walls or earth <br />berms may be utilized as appropriate to the building, addition <br />or alteration project to mitigate sound migration to the interior. <br />5.507.4.2.1 <br />Documentation of compliance –An acoustical analysis <br />documenting complying interior sound levels shall be <br />prepared by personnel approved by the architect or engineer <br />or record. <br />5.507.4.2.2 <br />Ozone depletion and greenhouse gas reductions – <br />Installations of HVAC, refrigeration, and fire suppression shall <br />not contain CFCs or Halons. <br />5.508.1 Contractor / <br />Installer <br />Product data for refrigerants <br />and/or fire suppression <br />materials <br />Building assemblies comply using the <br />prescriptive method below. <br />Refer to notes on mechanical plans. <br />N/A -Project is an alteration and does not use <br />new HVAC systems. <br />5.410.4 <br />PLANNING + DESIGN <br />WATER EFFICIENCY + CONSERVATION <br />MATERIAL CONSERVATION + RESOURCE EFFICIENCY <br />ENVIRONMENTAL QUALITY <br />Stormwater pollution prevention –For project sites <br />disturbing less than one acre of land, comply with local <br />ordinances for stormwater management and/or erosion <br />control; and/or implement BMPs for erosion/sediment control. <br />N/A -Project does not disturb land. <br />Short-term bicycle parking –For projects adding ten or <br />more visitor vehicle parking spaces, provide permanently- <br />anchored, readily-visible bicycle racks within 200' of visitors' <br />entrance, equal to 5% of new visitor vehicle capacity (min 2). <br />N/A -Project doesn't add visitor parking spaces. <br />Long-term bicycle parking –For projects adding vehicular <br />parking for 10 or more tenant-occupants, provide secure <br />bicycle parking equal to 5% of the tenant-occupant vehicular <br />parking spaces (minimum 1 bicycle parking facility). <br />N/A -Project doesn't add tenant-occupant parking <br />spaces. <br />Electric vehicle (EV) charging –At new projects containing <br />ten or more vehicle parking spaces, provide EV capable <br />spaces and supply equipment (quantity per Table 5.106.5.3.1). <br />Light pollution reduction –Design and install outdoor <br />lighting systems to comply with the following: <br />-Min. requirements for Lighting Zones 0-4 per CEC <br />-Backlight ratings per IES TM-15-11 <br />-Uplight and Glare ratings per CEC <br />-Allowable BUG (backlight/uplight/glare) ratings per Table <br />5.106.8 <br />OR comply with local ordinance, whichever is more stringent. <br />Grading and paving –Indicate how site grading or a <br />drainage system will manage all surface water flows to <br />keep water from entering buildings. <br />N/A -Project does not alter the drainage path. <br />Water meters –In new buildings or additions in excess of <br />50,000 s.f., provide separate water meters or submeters for: <br />1. Each individual tenant space projected to consume more <br />than 100 gal/day <br />2. Where submeters for individuals tenants is not feasible, <br />add submeters to the following systems: <br />a. Makeup water for cooling towers <br />(where flow through > 500 gpm) <br />b. Makeup water for evaporative coolers <br />(where flow through > 6 gpm) <br />c. Steam and hot-water boilers <br />(where energy input > 500,000 Btu/h) <br />5.303.1.2 Water meters –Provide a separate submeter or metering <br />device for any tenant within a new building or addition that <br />is projected to consume more than 1,000 gal/day <br />Water closet effective flush volume shall not exceed <br />1.28 gallons per flush. <br />N/A -Project provides no new plumbing. <br />N/A -Project provides no water closets. <br />N/A -Project provides no urinals.Urinal flush volume shall not exceed: <br />-0.125 gal/flush at wall-mounted urinals <br />-0.5 gal/flush at floor-mounted or other urinals <br />N/A -Project provides no showers. <br />N/A -Project provides no showers. <br />Standards –Plumbing fixtures and fittings shall be installed <br />in accordance with the CPC, and shall meet applicable <br />standards in Table 1701.1 of the CPC and in Ch. 6 of CGBC. <br />N/A -Project provides no irrigation.Outdoor potable water use in landscape areas shall <br />comply with either a local water efficient landscape <br />ordinance, or the current California Department of Water <br />Resources' Model Water Efficient Landscape Ordinance <br />(MWELO), whichever is more stringent <br />Weather protection –Provide a weather-resistant exterior <br />wall and foundation envelope as required by California <br />Building Code Section 1402.2, manufacturer's installation <br />instructions, or local ordinance, whichever is more stringent. <br />Install flashings integrated with a drainage plane. <br />Moisture control, entries and openings – <br />At exterior entries and/or openings which are subject to foot <br />traffic or wind-driven rain, prevent water intrusion by: <br />• using nonabsorbent floor and wall finishes within at least 2 <br />feet around and perpendicular to the opening <br />• providing 4 feet of shelter, through either an awning, an <br />overhang, or a recess <br />5.407.2.2.2 <br />Construction waste management –Recycle and/or reuse <br />65% min of nonhazardous construction/demolition waste <br />(per Section 5.408.1.1, 5.408.1.2 or 5.408.1.3); <br />or comply with local construction/demolition waste <br />management ordinance, whichever is more stringent. <br />N/A -Project is an alteration. <br />N/A -Project provides no irrigation. <br />Construction waste management plan –Where the local <br />jurisdiction does not have a construction and demolition <br />waste management ordinance that is more stringent, submit <br />a construction waste management plan that complies with <br />Section 5.408.1.1 <br />Excavated soil and land clearing debris (trees, stumps, <br />rocks and vegetation) shall be 100% reused or recycled <br />Recycling by occupants –Provide an area identified and <br />used for depositing, storage and collection of non-hazardous <br />recyclable materials. <br />Commissioning for new buildings 10,000 s.f. and greater: <br />1. Owner's Project Requirements (OPR) <br />2. Basis of Design (BOD) <br />3. Commissioning Plan <br />4. Functional Performance Testing <br />5. Documentation and training <br />6. Commissioning Report <br />N/A -Project provides no fireplaces. <br />N/A -No designated outdoor smoking area <br />provided. <br />N/A -Building contains no tenant spaces. <br />Supermarket refrigerant leak reduction –New commercial <br />refrigeration systems shall comply with the provisions of this <br />section when installed in retail food stores that both: <br />• have 8,000 s.f. or more of conditioned area <br />• utilize either refrigerated display cases, walk-in coolers, or <br />walk-in freezers connected to remote compressor units or <br />condensing units <br />Prescriptive method –At the locations listed below, building <br />envelope wall and roof-ceiling assemblies shall have a <br />minimum composite STC rating of 50, and exterior windows <br />shall have a minimum STC rating of 40: <br />• Within the 65 CNEL noise contour of an airport <br />• Within the 65 CNEL or Ldn noise contour of a freeway, <br />expressway, railroad, industrial source, or fixed guideway. <br />N/A -Building not within 65 CNEL noise contours <br />of an airport, freeway, expressway, railroad, <br />industrial source, or fixed guideway. <br />N/A -Building not exposed to noise level of <br />65 dB Leq-1-hr during any hour of operation. <br />N/A -Building not within categories of sound <br />concern. <br />N/A -No site features provided to mitigate sound. <br />Testing and adjusting of systems for new buildings less <br />than 10,000 s.f.: <br />1. Develop a written plan of procedures for testing and <br />adjusting HVAC systems and controls, indoor and outdoor <br />lighting and controls, water heating systems, renewable <br />energy systems, landscape irrigation systems, and water <br />reuse systems, if any. <br />2. Perform testing, adjusting and balancing procedures in <br />accordance with project specifications <br />3. Provide final report of testing signed by the individual <br />responsible for performing the tests <br />4. Provide building owner with operation and maintenance <br />manual. <br />N/A -Project provides no commercial <br />refrigerated display cases, walk-in coolers, <br />or walk-in freezers <br />Refer to notes on mechanical plans. <br />N/A -Building not within categories of sound <br />concern. <br />NONRESIDENTIAL MANDATORY MEASURES <br />pr <br />e <br />s <br />c <br />r <br />i <br />p <br />t <br />i <br />v <br />e <br /> <br />m <br />e <br />t <br />h <br />o <br />d <br />pe <br />r <br />f <br />o <br />r <br />m <br />a <br />n <br />c <br />e <br /> <br />m <br />e <br />t <br />h <br />o <br />d <br /> <br />N/A -Building provides no new mechanical <br />ventilation systems. <br />Refer to wall schedules on A2.2 and <br />roof assembly details on A7.2. <br />N/A -Project not new or addition. <br />N/A -Project does not alter exterior lighting. <br />N/A -Alteration adds no square footage to the <br />building. <br />N/A -Alteration does not affect the building's <br />exterior walls or foundation. <br />N/A -Project does not alter exterior openings. <br />N/A -Project does not disturb soil. <br />N/A -Alteration does not affect building exterior. <br />N/A -Project is an alteration. <br />N/A -Project is a renovation. <br />5.504.4.7 <br />5.504.4.8 <br />Contractor / <br />Installer <br />Product data for <br />installed materials <br />Contractor / <br />Installer <br />Product data for <br />installed materials <br />Thermal Insulation –Comply with the requirements of the <br />California Department of Public Health, “Standard Method for <br />the Testing and Evaluation of Volatile Organic Chemical <br />Emissions from Indoor Sources Using Environmental <br />Chambers,” Version 1.2, January 2017. Provide verification <br />of compliance documentation. <br />Acoustical ceiling and wall panels –Comply with the <br />requirements of the California Department of Public Health, <br />“Standard Method for the Testing and Evaluation of Volatile <br />Organic Chemical Emissions from Indoor Sources Using <br />Environmental Chambers,” Version 1.2, January 2017. <br />Provide verification of compliance documentation. <br />Refer to Interior Finish Schedule and <br />Specification Section 072100. <br />Refer to Interior Finish Schedule and <br />Specification Sections 092313, 095113, <br />095323, and 098413. <br />5.106.5.4 Electric vehicle (EV) charging (medium-and heavy-duty) – <br />At new Grocery, Retail, and Warehouse buildings, provide <br />spare raceway(s)/busway(s) and capacity for off-street <br />loading spaces (quantity and capacity per Table 5.106.5.4.1). <br />N/A -Project is a renovation. <br />Resilient flooring –For 80% of the floor area receiving <br />resilient flooring, install products complying with the California <br />Department of Public Health, “Standard Method for the <br />Testing and Evaluation of Volatile Organic Chemical <br />Emissions from Indoor Sources Using Environmental <br />Chambers,” Version 1.2, January 2017. Provide verification <br />of compliance documentation. <br />L <br />ROFIEFAOT <br />C <br />NO. C 30857 <br />REN. 3−31−23ATS <br />ICE <br />L <br />AIN <br />TC <br />TEI <br />ADNSE HCR <br />MELANIE A .VIEUX <br />Copyright WMB, Inc. <br />DATE PURPOSE <br />PUBLISH HISTORY: <br />No. <br />2000 L Street <br />Suite 125 <br />Sacramento, CA 95811 <br />T 209.944.9110 <br />F 209.944.5711 <br />www.wmbarchitects.com <br />5757 Pacific Avenue <br />Suite 226 <br />Stockton, CA 95207 <br />WMB Project No. <br />4/6/2023 9:21:09 AM <br />T2.2 <br />CALGREEN CODE <br />COMPLIANCE <br />03.03.23 PERMIT SUBMITTAL <br />04.06.23 PLAN CHECK 011 <br />Santa Ana Federal <br />Credit Union Tenant <br />Improvement <br />23-014 <br />800 W Santa Ana Blvd <br />Santa Ana, CA 92701 <br />800 W Santa Ana <br />Blvd. - 10111445404/06/23