Laserfiche WebLink
TACTILE SIGN - <br />INSTALL ON LATCH SIDE <br />OF DOOR <br />* <br />SINGLE DOOR PLAN <br />SINGLE DOOR ELEVATION <br />18" x 18" CLR. FLOOR SPACE, <br />CENTERED ON TACTILE CHARACTERS, <br />BEYOND ARC OF DOOR <br />TACTILE SIGN - <br />INSTALL ON RIGHT SIDE <br />OF DOUBLE DOORS <br />* <br />DOUBLE DOOR ELEVATION <br />9" MIN. FROM OUTSIDE <br />EDGE OF DOOR JAMB <br />9" MIN. FROM OUTSIDE <br />EDGE OF DOOR JAMB <br />DOOR LEVER / LATCH <br />DOOR LEVER / LATCH <br />CONTRACTED GRADE 2 BRAILLE <br />CENTERED BELOW ENTIRE TEXT <br />+60" A.F.F. MAX. TO <br />BASELINE OF <br />HIGHEST CHARACTER <br />+48" A.F.F. MIN. TO <br />BASELINE OF <br />LOWEST LINE OF BRAILLE <br />EXIT <br />5/ <br />8 <br />" <br /> <br />M <br />I <br />N <br />. <br />2" <br /> <br />M <br />A <br />X <br />. <br />NOTES: <br />1. CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON -GLARE FINISH. <br />CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND <br />(LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND) <br />2. REFER TO TACTILE SIGN LOCATION DETAIL FOR SIGN LOCATION RELATIVE TO DOORS <br />3. BRAILLE SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 11B OF THE C.B.C., <br />LATEST EDITION <br />4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION <br />TACTILE UPPERCASE SANS-SERIF <br />LETTERS, CHARACTERS RAISED 1/32" <br />3/ <br />8 <br />" <br /> <br />M <br />I <br />N <br />. <br />1 <br />/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />3/ <br />8 <br />" <br /> <br />M <br />I <br />N <br />. <br />1/4" RADIUS - TYP. <br />EXIT ROUTE <br />ALTERNATE SIGN TYPES (REFER TO SCHEDULE): <br />OPEN OFFICE <br />100 <br />VAULT <br />104 <br />DATA <br />105 <br />ELEC. <br />106 <br />JAN. <br />109 <br />STOR. <br />110 <br />KITCHEN <br />111 <br />TRAINING <br />112 <br />BOARD ROOM <br />113 <br />OFFICE <br />114 <br />CEO OFFICE <br />115 <br />OFFICE <br />116 <br />QUIET ROOM <br />117 <br />OPEN OFFICE <br />118 <br />1a <br />1a <br />1a <br />(E) <br />(E) <br />(E) <br />TOILET <br />108 <br />TOILET <br />107 <br />BRANCH <br />101 <br />TELLERS <br />103 <br />OFFICE <br />102 <br />HAND-ACTIVATED DOOR OPENING <br />HARDWARE, HANDLES, PULLS, <br />LATCHES, AND LOCKS <br />ELEVATION VIEW <br />PLAN VIEW <br />PUSH SIDE <br />PULL SIDE <br />* <br />34 <br />" <br /> <br />M <br />I <br />N <br />. <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />PROVIDE THIS ADDITIONAL <br />SPACE (SHADED AREA) <br />IF DOOR IS EQUIPPED WITH <br />BOTH A LATCH AND A CLOSER <br />12" MIN. <br />THE FORCE REQUIRED TO ACTIVATE <br />OPERABLE DOOR HARDWARE SHALL <br />BE 5 POUNDS MAX. <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />24" MIN. CLR. AT EXT. DOORS <br />18" MIN. CLR. AT INT. DOORS <br />1 <br />/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />1 <br />/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />1 <br />/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />VERTICAL CHANGE IN LEVEL @ <br />FLOOR/GROUND SURFACES <br />1 <br />2 <br />MAX. SLOPE <br />BEVELED CHANGE IN LEVEL @ <br />FLOOR/GROUND SURFACES <br />* <br />80 <br />" <br /> <br />M <br />I <br />N <br />. <br />4" MAX. <br />PROTRUSION <br />LEADING EDGE <br />GREATER THAN <br />27" A.F.F. <br />PROTRUSIONS ABOVE <br />MAY NOT ENCROACH <br />INTO CIRCULATION <br />BEYOND 80" A.F.F. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />8" MIN. <br />11" MIN.6" MAX. <br />19"-25" <br />MI <br />N <br />. <br />9" <br />24" MAX. <br />COUNTERTOP OR <br />WORK SURFACE <br />COMBINED REQUIRED <br />KNEE AND TOE <br />CLEARANCE <br />NOTE: FOR REQUIRED <br />KNEE/TOE CLEARANCE <br />AT LAVATORIES, <br />REFER TO ACCESSIBLE <br />LAVATORY DETAIL <br />SINK, WHERE <br />OCCURS <br />L <br />ROFIEFAOT <br />C <br />NO. C 30857 <br />REN. 3−31−23ATS <br />ICE <br />L <br />AIN <br />TC <br />TEI <br />ADNSE HCR <br />MELANIE A .VIEUX <br />Copyright WMB, Inc. <br />DATE PURPOSE <br />PUBLISH HISTORY: <br />No. <br />2000 L Street <br />Suite 125 <br />Sacramento, CA 95811 <br />T 209.944.9110 <br />F 209.944.5711 <br />www.wmbarchitects.com <br />5757 Pacific Avenue <br />Suite 226 <br />Stockton, CA 95207 <br />WMB Project No. <br />4/6/2023 9:21:10 AM <br />T3.1 <br />POSTED SIGNAGE PLAN + <br />DETAILS <br />03.03.23 PERMIT SUBMITTAL <br />04.06.23 PLAN CHECK 011 <br />Santa Ana Federal <br />Credit Union Tenant <br />Improvement <br />23-014 <br />800 W Santa Ana Blvd <br />Santa Ana, CA 92701 <br />1/4" = 1'-0" <br />TYP. TACTILE SIGN LOCATION AT DOOR <br />3" = 1'-0"A TACTILE EXIT SIGN <br />NOTE: DETAIL REFERENCES REFER TO DETAILS THIS SHEET U.O.N. <br />NO. SIGN TYPE TEXT DETAIL <br />1a TACTILE EXIT - EXTERIOR DOOR EXIT A <br />POSTED SIGNAGE SCHEDULE <br />1/8" = 1'-0" <br />POSTED SIGNAGE PLAN <br />1/4" = 1'-0" F ACCESSIBLE DOOR <br />6" = 1'-0"G VERTICAL OFFSETS <br />1/4" = 1'-0"4 PROTRUSION LIMITS <br />1/2" = 1'-0"E KNEE & TOE CLEARANCE @ WORK SURFACE <br />800 W Santa Ana <br />Blvd. - 10111445404/06/23