Laserfiche WebLink
Section 220.82 Dwelling Unit <br />Part #1 - Section 220.82 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: <br />Amps Box A (VA) <br />20.5 4920 <br />Part #2 - Section 220.82 <br />Size in VA Size in VA <br />1500 N/A <br />3000 N/A <br />1000 N/A <br />600 N/A <br />1000 N/A <br />1600 N/A <br />3840 N/A <br />7680 N/A <br />N/A N/A <br />N/A Amps Box B (VA) <br />N/A 84.25 20220 <br />Total VA from Parts #1 and #2 combined:Box A + Box B =25140 <br />Total VA 25140 <br />First 10,000 VA @ 100%10000 Remaining VA @ 40% <br />Remaining VA =15140 15140 x 40% =6056 VA <br />Adding First 10,000 VA 10000 VA <br />Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:16056 VA <br />Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:66.90 Amps <br />Part #3 - Section 220.82 (C) Heating and A/C loads: <br />*Combine the larger loads of either the Heating or the A/C loads togther <br />100% of all the Heating or A/C loads in VA:0 VA <br />100% of all the Heating or A/C loads in Amps:0.00 A <br />VA Volts Amps <br />Parts #1 & #2 16056 240 66.90 <br />Part #3 0 240 0.00 <br />Total VA for all Parts:16,056 <br />Totals Service/Feeder Load 66.90 <br />#ESTAMP <br />Laundry <br />Appliance Circuit(s) <br />Dishwasher(s) <br />Disposal(s) <br />Dedicated circuit <br />House <br />Square Footage <br />1640 <br />Article 220 - Service/Feeder calculation for (address): <br />901 Westwood Ave Santa Ana CA US 92703 <br />Building VA (watts) <br />4920 <br />Amps <br />20.5 <br />Job Code <br />109R-901GUER2 <br />Totals from all Parts <br />Dedicated circuit <br />Total for Part #1: <br />Refrigerator(s) <br />Microwave(s) <br />Totals for Part #2: <br />Other <br />Other <br />Oven <br />Pool Equipment