Laserfiche WebLink
TO <br />GROUND <br />RODS <br />39 <br />2524 <br />23 <br />14 40 <br />12 <br />38 <br />5 <br />7 <br />13 <br />C1 BY SCE <br />C2 & C3, 3" PVC, <br />TO DS-SW-1 & <br />DS-SW-2 <br />SECTION B-B <br />8 <br />1'-8" <br />2'-10"3'-6" <br />1'-0"6'-4" <br />14 <br />21 20 <br />41 31 <br />C6, 3" PVC, <br />TO EV-XFMR <br />22 22 <br />400/3 <br />400/3 <br />250/3 <br />E0 <br />1 <br />B <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />S <br />SH <br />E <br />E <br />T <br />DA <br />T <br />E <br />05 <br />/ <br />1 <br />6 <br />/ <br />2 <br />0 <br />2 <br />3 <br />CH <br />A <br />R <br />G <br />E <br /> <br />R <br />E <br />A <br />D <br />Y <br /> <br />P <br />R <br />O <br />G <br />A <br />M <br /> <br />TO <br />M <br />' <br />S <br /> <br />T <br />R <br />U <br />C <br />K <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br /># <br />2 <br /> C <br />R <br />T <br />- <br />2 <br />0 <br />2 <br />1 <br />- <br />0 <br />1 <br />1 <br />2 <br />SCALE: <br />ELECTRICAL EQUIPMENT PAD1 <br />E01B 1"=1'-0" <br />1.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO <br />COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND <br />NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS <br />FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES <br />ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME <br />ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION, <br />2.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM <br />SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF <br />ELECTRODES. <br />3.ALL CONDUITS SHALL COMPLY WITH CEC/NEC TABLE 300.5 MINIMUM BURIAL <br />DEPTH. <br />4.PER CEC/NEC 110.26 ”ACCESS AND WORKING SPACE SHALL BE PROVIDED AND <br />MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE <br />OPERATION AND MAINTENANCE OF SUCH EQUIPMENT.” <br />5.CONCRETE PADS SHALL REACH 100% DESIGN STRENGTH PRIOR TO DRILLING FOR <br />ANCHORS. <br />6.CONTRACTOR TO MEET SCE SWITCHGEAR SPECIFICATIONS. <br />GENERAL NOTES: <br />DISTRIBUTION EQUIPMENT BILL OF MATERIALS <br />ITEMREFERENCE <br />NUMBER QUANTITY <br />9 1/2" DIAMETER SS 316 KWIK BOLT TZ EXPANSION ANCHORS <br />WITH 3 1/4" MIN EFFECTIVE EMBEDMENT. (ICC ESR-1917)AR <br />10 ARGALVANIZED NUT, 1/2" <br />11 ARGALVANIZED LOCK WASHER, 1/2" <br />20 AR3" SCH. 40 PVC, CONDUIT <br />21 83" SCH. 40 PVC, 90 DEG ELBOW <br />22 3" SCH. 40 PVC, BELL END <br />26 <br />12 1 EAILSCO BUS BAR NO. BBFC-4-10-22A KIT OR EQUAL <br />13 1 EACUSTOMER SUPPLIED PADLOCK <br />23 61.5" PVC BELL END <br />24 1.5" SCH. 40 PVC CONDUIT <br />25 61.5" SCH. 40 PVC, 90 DEG ELBOW <br />AR <br />HPS, TRANSFORMER CASE STYLE DH4, NEMA TYPE 3R, <br />480-208/120V, 3Ø, 225 KVA1 1 <br />Z POWER SWITCHBOARD, NEMA TYPE 3R, 208/120V, 3Ø, 4W, 600 <br />AMP BUS, 42 KAIC FULLY RATED <br />MAIN BREAKER, 208 VOLT, 500 AMP TRIP, 42 KAIC IR AT 208V, <br />3 POLE <br />BRANCH BREAKER, GE, TYPE TEYH, 100 AMP TRIP, 42 KAIC, 2 <br />POLE <br />2 1 <br />3 1 <br />4 4 <br />14 AR2/0 BARE COPPER GROUND WIRE <br />15 5/8 GROUND ROD COPPER CLAD 10' ERICO INSTALLED <br />VERTICALLY WITH MIN. 1' EARTH COVER 4 <br />16 42/0 TO 5/8 ROD CLAMP, BURNDY MODEL NO. YGHR26C58 <br />8 <br />20A 1-POLE BREAKERS <br />29 <br />27 <br />28 <br />30 <br />31 AR#1/0 WIRE CONDUCTOR THWN-2 <br />33 AR250 KCMIL WIRE CONDUCTOR THWN-2 <br />5/8" DIAMETER SS 316KWIK BOLT TZ EXPANSION ANCHORS WITH <br />32 AR#8 WIRE CONDUCTOR THWN-2 <br />4 <br />34 AR#2 WIRE CONDUCTOR THWN-2 <br />37 <br />35 <br />36 <br />3/4" SCH, 40 PVC, CONDUIT <br />3/4" SCH, 40 PVC, 90 DEG ELBOW 4 <br />AR <br />3/4" SCH. 40 PVC, BELL END 4 <br />5 Z POWER SWITCHBOARD WITH METER, NEMA 3R, 480/277V, 3Ø, <br />4W, 1000A, 65 KAIC FULLY RATED, TWO SECTIONS 1 <br />6 MAIN BREAKER, 480V, 1000A, 65 KAIC, 3 POLE 1 <br />7 2BRANCH BREAKER, 480V, 400A, 65 KAIC, 3 POLE <br />8 BRANCH BREAKER, 480V, 250A, 65 KAIC, 3 POLE 1 <br />38 SCH. 40 PVC CONDUIT, SIZE BY SCE <br />39 ARSCH. 40 PVC CONDUIT RADIUS, SIZE BY SCE <br />40 SCH. 40 PVC CONDUIT BELL END, SIZE BY SCE AR <br />AR <br />41 AR500 KCMIL WIRE CONDUCTOR THWN-2 <br />GALVANIZED NUT, 5/8" <br />GALVANIZED LOOK WASHER, 5/8" <br />NOT USED <br />3 1/4" MIN EFFECTIVE EMBEDMENT. <br />AR <br />AR <br />AR <br />6/30/20256-30-2025 <br />909 N Grand Ave - <br />101116238 & 201806132/15/2024