Laserfiche WebLink
N <br />JE <br />F <br />F <br /> <br />F <br />I <br />S <br />H <br />E <br />R <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />91 <br />2 <br /> <br />F <br />R <br />E <br />E <br />M <br />A <br />N <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />Project Name & Address <br />Sheet Number <br />PV 1.0 <br />Sheet Name <br />DRAWN BY <br />MD <br />AH <br />J <br /> <br />- <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />I <br />R <br />V <br />I <br />N <br />E <br />DATE: 04/07/2023 <br />SITE PLAN <br />ROOF SECTIONS <br />SCALE: 3/32" = 1'-0" <br />1 SITE PLAN <br />PV 1.0 <br />SYSTEM LEGEND <br />16 NEW HANWHA Q.PEAK DUO BLK <br />ML-G10+(400W) WITH NEW 16 - ENPHASE <br />IQ8PLUS-72-2-US, 240V INVERTERS, MOUNTED ON <br />THE BACK OF EACH MODULES. <br />= EXTERIOR RUN <br />= ATTIC RUN <br />= CONDUIT ROOF TOP JUNCTION BOX <br />= CONDUIT ATTIC RUN JUNCTION BOX <br />= ATTACHMENT POINTS <br />= ROOF OBSTRUCTIONS, VENT, CHIMNEY <br />CIRCUIT #2 - 08 MODULES <br />CIRCUIT #1 - 08 MODULES <br />CIRCUIT(S) <br />NEW JUNCTION BOX JB <br />= TRUSSES <br />MODULE, ARRAY WEIGHT (LOAD CALC'S) <br />Number of Modules 16 <br />Module Weight 48.5 LBS <br />Total Module (Array) Weight 776.00 LBS <br />Number of Attachment point 60 <br />Mounting System Weight <br />(Per Module)2.5 LBS <br />Mounting System Weight 90.00 LBS <br />Total System Weight <br />(Module Weight + Mounting System Weight)866.00 LBS <br />Weight at Each Attachment Point <br />(Array Weight / Number of Attachment Point)14.43 LBS <br />Module Area (74.0"x41.1")21.12 SqFt <br />Total Array Area 337.93 SqFt <br />Distributed Load <br />(Total System Weight / Total Array Area)2.37 Per SqFt <br />Total Roof Area 880.41 SqFt <br />Total Percentage or Roof Covered <br />Total Array Area / Total Roof Area)*100 38.38% <br />= FIRE SETBACK & PATHWAY <br />ATTACHMENT SPACING : 6'-0" <br />EXISTING EXTERIOR METER/MAIN SERVICE PANEL & <br />POINT OF INTERCONNECTION. TIED TO EXTERIOR <br />UTILITY METER. <br />NEW DEDICATED PV SYSTEM COMBINER PANEL.C <br />NEW 30A NON-FUSED AC DISCONNECTAC <br />M <br />MODULE - 16 <br />SLOPE - 05° <br />AZIMUTH - 180° <br />MATERIAL - FLAT ROOF <br />RAFTERS SIZE & SPACING - 2"X4" @ 24" O.C. <br />ROOF #01 <br />ROOF #01 <br />C <br />A <br />C <br />M <br />JB <br />FR <br />O <br />N <br />T <br /> <br />O <br />F <br /> <br />H <br />O <br />U <br />S <br />E <br />91 <br />2 <br /> <br />F <br />R <br />E <br />E <br />M <br />A <br />N <br /> <br />S <br />T <br />(N) TRENCH ON-SITE <br />TRENCHING THROUGH DIRT APPROX <br />27'-0" PVC CONDUIT (MIN. 18" DEPTH) <br />6'-0" <br />BA <br />C <br />K <br /> <br />O <br />F <br /> <br />H <br />O <br />U <br />S <br />E <br />Signed: 06/19/2023 <br />Structural <br />Only <br />1 <br />1 <br />'- <br />0 <br />" <br />5'-0" <br />1 <br />0 <br />'- <br />0 <br />" <br />15'-0" <br />(E) patio cover without electrical <br />(E) shed without electrical <br />912 N. Freeman <br />Street08/29/23