Ex. Garage
<br />N
<br />Ex. Garage
<br />Door to be
<br />removed
<br />SAW CUT EXISTING
<br />CONCRETE 12" WIDE
<br />BREAK AND DEMO
<br />20' - 0"
<br />20
<br />'
<br />
<br />-
<br />
<br />0
<br />"
<br />20' - 0"
<br />20
<br />'
<br />
<br />-
<br />
<br />0
<br />"
<br />EX. HIP ROOF FRAMING
<br />TO REMAIN
<br />4:
<br />1
<br />2
<br />4:
<br />1
<br />2
<br />4:124:12
<br />22' - 0"
<br />22
<br />'
<br />
<br />-
<br />
<br />0
<br />"
<br />1' - 0"
<br />1'
<br />
<br />-
<br />
<br />0
<br />"
<br />1' - 0"
<br />1'
<br />
<br />-
<br />
<br />0
<br />"
<br />N.Landing
<br />3' x 4'
<br />5
<br />01-A-05
<br />6
<br />01-A-05
<br />N
<br />01-A-05
<br />3
<br />01-A-05201-A-05 4
<br />01-A-05
<br />1
<br />Landing 7 3/4"
<br />max. below
<br />threshold
<br />Bedroom
<br />Bedroom
<br />CL
<br />CL
<br />Bathroom
<br />Kitchen/Dining
<br />Living space
<br />W
<br />D
<br />15"
<br />min
<br />15"
<br />min
<br />30" MIN
<br />ø 3' - 0"
<br />New 22"x30"
<br />Attic Access
<br />A
<br />B
<br />B
<br />B
<br />C
<br />C
<br />D
<br />12
<br />3
<br />3
<br />6' - 5"8' - 7"
<br />6'
<br />
<br />-
<br />
<br />0
<br />"
<br />8'
<br />
<br />-
<br />
<br />0
<br />"
<br />6'
<br />
<br />-
<br />
<br />0
<br />"
<br />12
<br />'
<br />
<br />-
<br />
<br />6
<br />"
<br />7'
<br />
<br />-
<br />
<br />6
<br />"
<br />16' - 9"3' - 3"2' - 5"11' - 7"
<br />34' - 0"
<br />10
<br />'
<br />
<br />-
<br />
<br />3
<br />"
<br />9'
<br />
<br />-
<br />
<br />1
<br />0
<br />"
<br />13' - 7"6' - 5"2' - 5"11' - 7"
<br />20
<br />'
<br />
<br />-
<br />
<br />0
<br />"
<br />Mini Split condenser
<br />W.H.
<br />6'
<br />
<br />-
<br />
<br />5
<br />"
<br />4
<br />1
<br />01-A-04
<br />Tempered
<br />Glass
<br />Tempered
<br />Glass
<br />EG
<br />R
<br />E
<br />S
<br />S
<br />
<br />W
<br />I
<br />N
<br />D
<br />O
<br />W
<br />EG
<br />R
<br />E
<br />S
<br />S
<br />
<br />W
<br />I
<br />N
<br />D
<br />O
<br />W
<br />SPACE MIN. 2.5' X 2.5' X 7' TALL
<br />FOR HPWH
<br />EX. WALL TO REMAIN
<br />EX. WALL TO BE DEMO
<br />WALL SCHEDULE
<br />NEW WALL
<br />1-HR RATED/ SOUND
<br />RATED (STC-50)
<br />6'
<br />
<br />-
<br />
<br />8
<br />"
<br />2
<br />2'-0"W x 2'-0"H SLIDING WINDOW VINY. YES
<br />MARK SIZE TYPE FRAME
<br />WINDOW SCHEDULE
<br />NOTES:
<br />1.BEDROOM EGRESS WINDOWS HAVE A MINIMUM CLEAR OPENING AREA OF 5.7 sf.
<br />ABOVE THE GRADE FLOOR AND 5 SQ.FT. ON THE GRADE FLOOR, A MIN. NET HEIGHT OF 24"
<br />AND MIN. NET WIDTH OF 20", AND SILL HEIGHT NOT MORE THAN 44" MAX. ABOVE FINISH
<br />FLOOR.
<br />2.THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS AND SKYLIGHTS (INCL.
<br />TUBULAR) MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED.
<br />3.SHOWER AND TUB ENCLOSURES SHALL BE TEMPERED (CBC 2406.4) WINDOWS AT
<br />SHOWERS AND TUBS SHALL BE TEMPERED.
<br />F.F.
<br />4'-0"W x 3'-0"H SLIDING WINDOW VINY. YES
<br />SCREEN
<br />1
<br />2
<br />QTY.
<br />1
<br />1
<br />2' - 0"
<br />2'
<br />
<br />-
<br />
<br />0
<br />"
<br />1
<br />4' - 0"
<br />3'
<br />
<br />-
<br />
<br />0
<br />"
<br />4'
<br />
<br />-
<br />
<br />0
<br />"
<br />4' - 0"
<br />3
<br />2 3 4'-0"W x 4'-0"H SLIDING WINDOW VINY. YES
<br />6'-0"W x 4'-0"H SLIDING WINDOW VINY. YES41
<br />6' - 0"
<br />4
<br />TEMPERED GLASS
<br />TEMPERED GLASS
<br />U-FACTOR SHGC
<br />0.29 0.22
<br />0.29 0.22
<br />0.29 0.22
<br />0.29 0.22
<br />A B
<br />A 3'-0" W X 6'-8" H 1 3/8" EXT. SOLID CORE DOOR WOOD WOOD
<br />B 2'-8" W X 6'-8" H 1 3/8" INT. HOLLOW CORE DOOR WOOD WOOD
<br />MARK OPENING SIZE TICK DOOR TYPE SCREEN FRAME
<br />DOOR SCHEDULE
<br />F.F.
<br />QTY.
<br />1
<br />3
<br />C 5'-0" W X 6'-8" H 1 3/8" DOUBLE SLIDING CLOSET DOOR WOOD WOOD2
<br />C
<br />6'
<br />
<br />-
<br />
<br />8
<br />"
<br />3' - 0"
<br />D
<br />D1 5'-3" W X 6'-8" H 1 3/8"DOUBLE FOLDING DOOR WOOD WOOD
<br />5' - 0"2' - 8"5' - 3"
<br />EX. HIP ROOF FRAMING
<br />TO REMAIN
<br />4:
<br />1
<br />2
<br />4:
<br />1
<br />2
<br />4:12
<br />22
<br />'
<br />
<br />-
<br />
<br />0
<br />"
<br />4:12
<br />4:
<br />1
<br />2
<br />4:
<br />1
<br />2
<br />NEW HIP ROOF FRAMING TO
<br />MATCH EXISTING
<br />COMPOSITION SHINGLES OVER #15 FELT CLASS
<br />"A"
<br />(TYP) CERTAINTED OR SIMILAR ESR-1389, 3537
<br />ICC-ES
<br />EX. GARAGE
<br />22' - 0"
<br />NEW ADD
<br />14' - 0"
<br />36' - 0"
<br />1'
<br />
<br />-
<br />
<br />0
<br />"
<br />1' - 0"
<br />1'
<br />
<br />-
<br />
<br />0
<br />"
<br />1' - 0"
<br />4:
<br />1
<br />2
<br />4:
<br />1
<br />2
<br />ALL SHINGLES TO MATCH THE
<br />MAIN HOUSE
<br />2
<br />01-A-04
<br />2
<br />01-A-04
<br />SEE ATTIC VENT CALCULATION VENT FOR ADD
<br />PROVIDE 1 SQ. IN. OF VENTILATION PER 150 SQ. IN. OF ATTIC SPACE.
<br />PROVIDE THAT 50% OF THE REQ. VENTILATION AREA IS PROVIDED BY
<br />VENTILATORS IN THE UPPER PORTION OF THE ATTIC, (HIGH VENTING) AT 3'-0"
<br />ABOVE EAVE VENT WITH THE BALANCE BEING PROVIDED BY EAVE VENTS,
<br />(LOW VENTING) PER I.R.C. R806, (U.B.C. 1505.3).
<br />ATTIC VENT CALCULATION ZONE
<br />VENTILATION REQUIRED:
<br />SQ. FT. / 150 =SQ. FT.2300ATTIC AREA
<br />X 144 =SQ. IN.288
<br />VENTILATION PROVIDED:
<br />72 SQ. IN. EA. =410
<br />SQ. IN.0
<br />SQ. IN.O HAGIN
<br />147 SQ. IN. EA. =-GABLE LOUVER VENT
<br />TOTAL VENTILATION PROVIDED:SQ. IN.288
<br />Project number
<br />Date
<br />Drawn by
<br />Checked by
<br />E-mail:skyaaconstruction@gmail.com
<br />THIS DESIGN AND DRAWINGS, ARE
<br />COPYRIGHT PROTECTED AND ARE
<br />THE EXCLUSIVE PROPERTY OF AA SKY
<br />CONSTRUCTION INC., THEY SHALL BE
<br />NO USED, MODIFIED DUPLICATED IN
<br />WHOLE OR IN ANY MANNER, NOR
<br />ASSIGNED TO A THIRD PARTY WITHOUT
<br />THE WRITTEN AUTHORIZATION
<br />OF AA SKY CONSTRUCTION INC.
<br />APPROVAL STAMP
<br />OWNER
<br />CONTACT PERSON
<br />DESIGNER
<br />AA SKY CONSTRUCTION INC.
<br />2074 SILVERADO ST.
<br />SAN MARCOS CA 92078
<br />LIC#1061749
<br />OFFICE 858 888 3752
<br />CELL 760 845 7697
<br />RAFAEL G LUJANO
<br />E-MAIL: SKYAACONSTRUCTION@GMAIL.COM
<br />CONSULTANTS
<br />01-A-03
<br />EXISTING FLOOR&ROOF
<br />PLAN, PROPOSED
<br />FLOOR&ROOF PLAN
<br />0001
<br />940 E ANAHURST PL.
<br />STA. ANA, CA 92707
<br />05-20-2024
<br />Autor
<br />Verificador
<br />EX. 400 SQ.FT.
<br />GARAGE+ NEW 280
<br />SQ.FT. TO BE A 680
<br />SQ.FT. ADU
<br />RAFAEL LUJANO
<br />RAFAEL LUJANO
<br />2201 HALLADAY ST. STA. ANA, CA 92707
<br />skyaaconstruction@gmail.com
<br />+17608457697
<br />ARCHITECTURAL NOTES
<br />1.PROVIDE 72" HIGH NON ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED
<br />SHATTER RESISTANT MATERIALS FOR SHOWER ENCLOSURE. MATERIALS OTHER THAN
<br />STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT.
<br />2.SIZE OF SHOWER STALL TO COMPLY WITH CPC 412.7, 1024 SQ. IN. MINIMUM INTERIOR
<br />AND ENCOMPASSING 30" CIRCLE. DOOR SHALL SWING TO THE OUTSIDE.
<br />3.LOW FLOW TOILETS (1.28 GALLON/FLUSH) -SHOWERHEADS (1.8 GPM @ 80 PSI)
<br />-LAVATORY FAUCETS (1.2 GPM @ 60 PSI)
<br />4.PROVIDE INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE
<br />THERMOSTATIC MIXING VALVE TYPE FOR SHOWERS AND TUB SHOWERS.
<br />5.PROVIDE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM OF
<br />4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS.
<br />6.DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE.
<br />7.CLOTHES DRYER MOISTURE EXHAUST DUCT IS LIMITED TO 14 FEET WITH 2 ELBOWS
<br />FROM THE CLOTHES DRYER TO POINT OF TERMINATION REDUCE THIS LENGTH BY 2 FEET
<br />FOR EVERY ELBOW IN EXCESS OF 2.
<br />8.UNIT SKYLIGHTS SHALL BE LABELED BY L.A CITY APPROVED LABELING AGENCY.SUCH
<br />LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND
<br />PERFORMANCE GRADE RATING.
<br />10. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING
<br />SHOWER HEADS AND TOILETS MUST BE UPDATED FOR LOW WATER CONSUMPTION.
<br />11. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED
<br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES,
<br />TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE
<br />LOCATION OF THE HOOK UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY
<br />POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO
<br />COMPLY MAY CAUSE CONSTRUCTION DELAYS AND OR ADDITIONAL EXPENSES.
<br />12. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE
<br />ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE
<br />EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING.
<br />13. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO THE WALL IN TWO
<br />PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND ONE IN THE LOWER 1/3 OF THE TANK. THE
<br />LOWER POINT SHALL BE A MINIMUM OF 4" ABOVE THE CONTROLS.(P.C.510.5) LOW IN EXCESS
<br />OF 2.
<br />14.PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR
<br />TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3).
<br />15. KITCHEN SINK LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND
<br />WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND
<br />CONNECTED TO AN APPROVED WATER SUPPLY (R306.4).
<br />16. BATHTUB AND SHOWER FLOORS, WALL ABOVE BATHTUBS WITH A SHOWERHEAD, AND
<br />SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH
<br />WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6' ABOVE THE FLOOR
<br />(R307.2).
<br />17. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH
<br />NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION
<br />R303.1 OR SHALL BR PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN
<br />AVERAGE ILLUMINATION OF 6' CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30"
<br />ABOVE THE FLOOR LEVEL. (R303.1)
<br />18. A COPY OF THE EVALUATION REPORT AND/ OR CONDITIONS OF LISTING SHALL BE
<br />MADE AVAILABLE AT THE JOB SITE.
<br />19. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMP' OF 68°F AT A
<br />POINT 3' ABOVE THE FLOOR AND 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE
<br />DESIGN TEMPERATURE.
<br />20.PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE
<br />PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY
<br />DURABLE WOOD OR WOOD THAT IS PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA
<br />U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE.PRESERVATIVES SHALL BE
<br />LISTED IN SECTION 4 OF AWPA U1.
<br />21. PROVIDE ANTI-GRAFFITI FINISH WITHIN THE FIRST 9 FEET,MEASURED FROM GRADE,AT
<br />EXTERIOR WALLS AND DOORS .EXCEPTION:MAINTENANCE OF BUILDING AFFIDAVIT IS
<br />RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGELES TO
<br />REMOVE ANY GRAFFITI WITHIN 7 DAYS OF THE GRAFFITI BEING APPLIED.(6306)
<br />UTILITY NOTES
<br />1 ALL BRANCH CIRCUTS SUPPLYING RECEPTACLES SHALL BE PROTECTED BY A
<br />LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI)
<br />2.ALL 120-VOLT, SINGLE PAHSE 15 AND 20 AMP BRANCH CIRCUIT SUPPLYING
<br />OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
<br />PARLORS, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS,
<br />LAUNDRY ROOMS OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY OF
<br />THE MEANS DESCRIBED IN 210.12 (A)(1). AT KITCHEN COUNTER SPACE, RECEPTACLES
<br />SHALL BE INDICATED AS COMBINATION AFCDI/GFCI.
<br />3.TAMPER RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED IN SECTION 210.52
<br />ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT
<br />RECEPTACLES
<br />4.NEW BOXES USED AT LUMINAIRES OR LAMPHOLDER OUTLETS IN A CEILING SHALL
<br />BE REQUIRED TO SUPPORT A LUMINAIRIE WEIGHING A MINIMUM OF 50 LB. BOXES USED AT
<br />LUMINARIE OUTLETS IN WALL SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE
<br />MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF LUMINAIRE PERMITTED,
<br />IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF
<br />CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR
<br />THIS PURPOSE. (314.27 CEC)
<br />5.ALL LEAD LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY NATIONAL
<br />ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS
<br />THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE
<br />COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN
<br />ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. (2019 RESIDENTIAL
<br />COMPLIANCE MANUAL 6.3.1(G)
<br />6.IN BATHROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THIS SPACES MUST BE
<br />CONTROLLED BY AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING
<br />AUTOMATIC-OFF FUNCTIONALITY. IF A OCCUPANT SENSOR IS INSTALLED, IT MUST BE
<br />INITIALLY CONFIGURED TO MANUAL-ON OPERATION USING THE MANUAL CONTROL
<br />REQUIRED UNDER SECTION 150.0(k)2C.
<br />ADDITIONAL NOTES
<br />1.PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN
<br />COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE
<br />BALANCED. CEC 210-52(B) (2)
<br />2.PROVIDE A MINIMUM OF (1) 20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT
<br />SHALL HAVE NO OTCOHER OUTLETS. CEC 210-23(A).
<br />3.A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT
<br />SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM
<br />CEC 210-23
<br />4.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE
<br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR.
<br />5.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING, OR
<br />TO OTHER BUILDING ON THE SAME LOT, MUST MEET THE REQUIREMENT IN ITEM
<br />150.0(K)3AI (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(K)3AII
<br />(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(K)3AIII (PHOTO CONTROL AND
<br />AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS
<br />6.ALL LIMINAIRES SHALL BE HIGH EFFICACY -PER SECTION 150.0(K)1A.
<br />7.CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(A).
<br />ADDITIONAL NOTES:
<br />1. HABITABLE SPACES SHALL HAVE CEILING HEIGHT OF NO LESS THAN 7'-6". KITCHENS,
<br />LAUNDRY ROOM, CORRIDORS AND BATHROOMS SHALL HAVE CEILING HEIGHT NOT
<br />LESS THAN 7'.
<br />2. PROVIDE 1 ESCAPE WINDOW IN EACH BEDROOM MEETING ALL OF THE FOLLOWING: AN
<br />OPENABLE AREA NOT LESS THAN 5.7 SQ.FT. MIN. CLEAR 24" HEIGHT AND 20" WIDTH
<br />AND SILL NOT OVER 44" ABOVE FLOOR
<br />3. SHOWER WALLS MUST BE FINISHED TO A HEIGHT OF 72" ABOVE DRAIN W/ MOISTURE
<br />RESISTIVE TILE OR APPROVED EQUAL
<br />4. MAX. FLOW RATE STANDARDS SET BY THE CALIFORNIA ENERGY COMMISION:
<br />F.SHOWER HEADS: 1.8 GPM @ 80 PSI
<br />G.LAVATORY FAUCETS: 1.2 GPM @ 60 PSI
<br />H.KITCHEN FAUCETS: 1.8 GPM @ 60 PSI
<br />I.WATER CLOSET: 1.28 GALLONS PER FLUSH
<br />5. EXTERIOR WALLS WITHIN 3 FEET OF PROPERTY LINE (SPRINKLERS) OR 5 FEET OF
<br />PROPERTY LINE (WITHOUT SPRINKLERS) REQUIRE 1-HOUR FIRE RATING FOR
<br />EXPOSURE TO BOTH SIDES
<br />6. PROJECTIONS: -PROHIBITED WITHIN 2 FEET OF PROPERTY LINE -1-HOUR FIRE
<br />RATING ON THE UNDERSIDE WITHIN 3FT OF PROPERTY LINE (SPRINKLERS) -1-HOUR
<br />FIRE RATING ON THE UNDERSIDE WITHIN 5FT OF PROPERTY LINE (WITHOUT
<br />SPRINKLERS)
<br />7. OPENINGS: -PROHIBITED WITHIN 3FT OF PROPERTY LINE -MAXIMUM 25% OF WALL
<br />AREA WITHIN 5 FEET OF PROPERTY LINE (WITHOUT SPRINKLERS)
<br />8. PENETRATIONS: -1-HOUR FIRE-RATED PENETRATIONS OF WALLS WITHIN 3FT OF
<br />PROPERTY LINE (SPRINKLERS) -1-HOUR FIRE-RATED PENETRATIONS OF WALLS
<br />WITHIN 5FT OF PROPERTY LINE (WITHOUT SPRINKLERS)
<br />1/4" = 1'-0"
<br />Existing Floor Plan 21
<br />1/4" = 1'-0"
<br />Existing Roof Plan 22
<br />1/4" = 1'-0"
<br />Proposed 1st Floor Plan3
<br />1/4" = 1'-0"
<br />Window Schedule ADU
<br />1/4" = 1'-0"
<br />Door Schedule ADU
<br />1/4" = 1'-0"
<br />Proposed Roof Plan4
<br />No. Description Date
<br />1 Revisión 1 Fecha 1
<br />OPENING SIZE ANALYSIS
<br />1HR FIRE RATED WALL AREA = 20' X 8' = 160 SQ.FT.
<br />160 SQ.FT. X 25% = 40 SQ.FT.
<br />WINDOW AREA = 4' X 4' = 16 SQ.FT.
<br /> 16 SQ.FT. X 2 = 32 SQ.FT.
<br /> ...OK
<br />940 E Anahurst Pl & 2201
<br />S Halladay11/25/2024
|