My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
940 E Anahurst Pl & 2201 S Halladay - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Anahurst Pl
>
940 E Anahurst Pl
>
940 E Anahurst Pl & 2201 S Halladay - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:21 PM
Creation date
6/1/2025 12:11:08 PM
Metadata
Fields
Template:
Plan
Permit Number
101120172
Full Address
940 E Anahurst Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A-9 <br />A-5 <br />A-1 <br />A-10 <br />A-2 <br />A-6 <br />4' <br /> <br />- <br /> <br />6 <br />" <br />7' <br /> <br />- <br /> <br />9 <br />" <br />0' <br /> <br />- <br /> <br />6 <br />" <br />12 <br />' <br /> <br />- <br /> <br />9 <br />" <br />A-7 <br />A-8 <br />3 3 <br />A-7 <br />A-1 <br />A-10 <br />A-2 <br />4' <br /> <br />- <br /> <br />6 <br />" <br />7' <br /> <br />- <br /> <br />9 <br />" <br />0' <br /> <br />- <br /> <br />6 <br />" <br />12 <br />' <br /> <br />- <br /> <br />9 <br />" <br />A-6 <br />OPENING SIZE ANALYSIS <br />1HR FIRE RATED WALL AREA = 20' X 8' = 160 SQ.FT. <br />160 SQ.FT. X 25% = 40 SQ.FT. <br />WINDOW AREA = 4' X 4' = 16 SQ.FT. <br /> 16 SQ.FT. X 2 = 32 SQ.FT. <br /> ...OK <br />1 2 <br />A-9 <br />A-15 <br />A-1 <br />A-10 <br />A-2 <br />A-5A-6 <br />0' <br /> <br />- <br /> <br />6 <br />" <br />7' <br /> <br />- <br /> <br />9 <br />" <br />4' <br /> <br />- <br /> <br />6 <br />" <br />12 <br />' <br /> <br />- <br /> <br />9 <br />" <br />A <br />A-9 <br />A-15 <br />A-7 <br />A-1 <br />A-10 <br />A-2 <br />A-5 <br />4' <br /> <br />- <br /> <br />6 <br />" <br />7' <br /> <br />- <br /> <br />9 <br />" <br />0' <br /> <br />- <br /> <br />6 <br />" <br />12 <br />' <br /> <br />- <br /> <br />9 <br />" <br />A-6 <br />4 A-8 <br />1 <br />2 <br />3 <br />4 <br />5 <br />7 <br />9 <br />10 <br />13 <br />15 <br />14 <br />Living space <br />Kitchen/Dining <br />I <br />02-S5.0 <br />I <br />02-S5.0 <br />I <br />02-S3.0 <br />26 <br />1 <br />7 <br />10 <br />14 <br />2 <br />3 <br />4 <br />5 <br />6 <br />9 <br />11 <br />13 <br />15 <br />4' <br /> <br />- <br /> <br />2 <br />" <br />8' <br /> <br />- <br /> <br />1 <br />" <br />0' <br /> <br />- <br /> <br />6 <br />" <br />12 <br />' <br /> <br />- <br /> <br />9 <br />" <br />Living space <br />CL BedroomVI <br />02-S3.0 <br />VIII <br />02-S3.0 <br />IX <br />02-S5.0 <br />VII <br />02-S5.0 <br />II <br />02-S5.0 <br />26 <br />Project number <br />Date <br />Drawn by <br />Checked by <br />E-mail:skyaaconstruction@gmail.com <br />THIS DESIGN AND DRAWINGS, ARE <br />COPYRIGHT PROTECTED AND ARE <br />THE EXCLUSIVE PROPERTY OF AA SKY <br />CONSTRUCTION INC., THEY SHALL BE <br />NO USED, MODIFIED DUPLICATED IN <br />WHOLE OR IN ANY MANNER, NOR <br />ASSIGNED TO A THIRD PARTY WITHOUT <br />THE WRITTEN AUTHORIZATION <br />OF AA SKY CONSTRUCTION INC. <br />APPROVAL STAMP <br />OWNER <br />CONTACT PERSON <br />DESIGNER <br />AA SKY CONSTRUCTION INC. <br />2074 SILVERADO ST. <br />SAN MARCOS CA 92078 <br />LIC#1061749 <br />OFFICE 858 888 3752 <br />CELL 760 845 7697 <br />RAFAEL G LUJANO <br />E-MAIL: SKYAACONSTRUCTION@GMAIL.COM <br />CONSULTANTS <br />01-A-05 <br />ELEVATIONS & SECTIONS <br />0001 <br />940 E ANAHURST PL. <br />STA. ANA, CA 92707 <br />05-20-2024 <br />Autor <br />Verificador <br />EX. 400 SQ.FT. <br />GARAGE+ NEW 280 <br />SQ.FT. TO BE A 680 <br />SQ.FT. ADU <br />RAFAEL LUJANO <br />RAFAEL LUJANO <br />2201 HALLADAY ST. STA. ANA, CA 92707 <br />skyaaconstruction@gmail.com <br />+17608457697 <br />UTILITY NOTES <br />1 ALL BRANCH CIRCUTS SUPPLYING RECEPTACLES SHALL BE PROTECTED BY A <br />LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI) <br />2.ALL 120-VOLT, SINGLE PAHSE 15 AND 20 AMP BRANCH CIRCUIT SUPPLYING <br />OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, <br />PARLORS, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, <br />LAUNDRY ROOMS OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY OF <br />THE MEANS DESCRIBED IN 210.12 (A)(1). AT KITCHEN COUNTER SPACE, RECEPTACLES <br />SHALL BE INDICATED AS COMBINATION AFCDI/GFCI. <br />3.TAMPER RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED IN SECTION 210.52 <br />ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT <br />RECEPTACLES <br />4.NEW BOXES USED AT LUMINAIRES OR LAMPHOLDER OUTLETS IN A CEILING SHALL <br />BE REQUIRED TO SUPPORT A LUMINAIRIE WEIGHING A MINIMUM OF 50 LB. BOXES USED AT <br />LUMINARIE OUTLETS IN WALL SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE <br />MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF LUMINAIRE PERMITTED, <br />IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF <br />CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR <br />THIS PURPOSE. (314.27 CEC) <br />5.ALL LEAD LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY NATIONAL <br />ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS <br />THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE <br />COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN <br />ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. (2019 RESIDENTIAL <br />COMPLIANCE MANUAL 6.3.1(G) <br />6.IN BATHROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THIS SPACES MUST BE <br />CONTROLLED BY AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING <br />AUTOMATIC-OFF FUNCTIONALITY. IF A OCCUPANT SENSOR IS INSTALLED, IT MUST BE <br />INITIALLY CONFIGURED TO MANUAL-ON OPERATION USING THE MANUAL CONTROL <br />REQUIRED UNDER SECTION 150.0(k)2C. <br />ADDITIONAL NOTES <br />1.PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN <br />COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE <br />BALANCED. CEC 210-52(B) (2) <br />2.PROVIDE A MINIMUM OF (1) 20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT <br />SHALL HAVE NO OTCOHER OUTLETS. CEC 210-23(A). <br />3.A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT <br />SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM <br />CEC 210-23 <br />4.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR. <br />5.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING, OR <br />TO OTHER BUILDING ON THE SAME LOT, MUST MEET THE REQUIREMENT IN ITEM <br />150.0(K)3AI (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(K)3AII <br />(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(K)3AIII (PHOTO CONTROL AND <br />AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS <br />6.ALL LIMINAIRES SHALL BE HIGH EFFICACY -PER SECTION 150.0(K)1A. <br />7.CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(A). <br />1/4" = 1'-0" <br />West Elevation ADU1 1/4" = 1'-0" <br />South Elevation ADU2 <br />1/4" = 1'-0" <br />East Elevation ADU3 1/4" = 1'-0" <br />North Elevation ADU4 <br />1/4" = 1'-0" <br />Section A-ADU5 <br />1/4" = 1'-0" <br />Section B-ADU6 <br />Elevation Keynotes ADU <br />MARK Texto de nota clave <br />A-1 COMPOSITION SHINGLES <br />OVER #15 FELT CLASS "A" <br />A-2 FASCIA <br />A-5 CONCRETE SLAB <br />A-6 26 GA. <br />CORROSION-RESISTANT <br />WEEP SCREED <br />A-7 MINI SPLIT CONDENSER <br />(SEE T-24) <br />A-8 WATER HEATER (SEE T-24) <br />A-9 EXTERIOR WALL LAMP <br />A-10 EXISTING STUCCO FINISH <br />A-15 WEATHER PROOF <br />RECEPTACLE <br />Section Keynotes ADU <br />MARK DESCRIPTION <br />1 COMPOSITION SHINGLES OVER #15 FELT <br />CLASS "A" (TYP) CERTAINTED OR SIMILAR <br />ESR-1389, 3537 ICC-ES <br />2 2"x" SILL PLATE W/ 5/8" DIA ANCHOR BOLTS <br />3 2"X" STUD WALL @16" O.C. TYPE DOUBLAS <br />FIR GRADE #2 STUD MIN. <br />4 DOUBLE 2x TOP PLATE AT EXTERIOR & <br />BEARING WALLS TYPE DOUGLAS FIR GRADE <br />#2 <br />5 R-15 FIBERBATT INSULATION SEE ENERGY <br />CALCS <br />6 R-30 FIBERBATT INSULATION SEE ENERGY <br />CALCS <br />7 2"x " R.R. @ 16" O.C. TYPE DOUGLAS FIR <br />GRADE #2 <br />8 2"x " C.J. @ 16" O.C. TYPE DOUGLAS FIR <br />GRADE #2 SEE STRUCTURAL <br />9 4" CONC. SLAB <br />10 4"x " HEADER TYPE DOUGLAS FIR GRADE #1 <br />11 2"X SOLID BLOCK W/ FRAMING ANCHOR EA. <br />BLOCK TYPE DOUGLAS FIR GRADE #2 <br />13 26 GA. CORROSION- RESISTANT WEEP <br />SCREED <br />14 1/2" GYP BOARD <br />15 12" FOOTING <br />26 PIER <br />ALL SHINGLES TO MATCH THE MAIN <br />HOUSE <br />NOTE: <br />The Exterior Material of the primary dwelling is Wood Siding <br />NOTE: <br />The Exterior Material of the primary dwelling is Wood Siding <br />NOTE: <br />WINDOW TRIM TO MATCH EXISTING <br />No. Description Date <br />1 Revisión 1 Fecha 1 <br />NEW HARD SIDING TO MATCH TO EX <br />R-22 FIBERBATT INSULATION SEE ENERGY CALCS <br />DETAIL <br />. <br />. <br />940 E Anahurst Pl & 2201 <br />S Halladay11/25/2024
The URL can be used to link to this page
Your browser does not support the video tag.