Laserfiche WebLink
CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />Zohrabians Art of Design <br />700 Palm Drive, Suite 106 <br />Glendale, CA 91202 <br />zartofdesign.com <br />818.300.9420 <br />No.Date Description <br />06/05/2024 100% DD SET <br />06/14/2024 50% CD PROGRESS SET <br />06/21/2024 75% CD PROGRESS SET <br />07/02/2024 NEIGHBORHOOD REVIEW <br />07/10/2024 1ST PLAN CHECK SUBMITTAL <br />82 <br />9 <br /> <br />N <br />. <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Santa Ana, CA 92701 <br />829 N. Garfield Street <br />Name: <br />Project Contact: <br />Phone: <br />Email: <br /> <br />Principal: <br />Z.AOD Project No:2024-02 <br />Arthur Zohrabians <br />818.300.9420 <br />Arthur Zohrabians <br />info@zartofdesign.com <br />Phone No.:949.922.7075 <br />Email:vanitapuri@gmail.com <br />Owner <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />Address: <br />Ren.11/30/25 <br />A <br />No. C37490 <br />A <br />A FOILOFC <br />R <br />INTA <br />S <br />ET <br />TC <br />A RCHITE <br />DESNECIL <br />RTHUR <br />HAMAYAK ZOHRAB <br />IA <br />SN <br />VVS Estates, LLC <br />Vanita Soni PuriAttn: <br />8 <br />11317 <br />24 <br />DOOR DETAILS <br />A912 <br />420 <br />21 <br />12 <br />22 <br />NOT USED DOOR DETAIL NOTES <br />SCALE: N.T.S.FILE NAME: <br />ICC - ESR 2097 REPORT PLI-DEK “F” SYSTEM = PLI-DEK 1-HOUR / CLASS “A” FIRE RATED <br />IMPERVIOUS SURFACE, FIBERGLASS AND RESIN REINFORCED WATERPROOF DECK COATING <br />WITH KNOCKDOWN TEXTURE APPLIED AS PER MFG SPECIFICATIONS. COLOR TBD. <br />WWW.PLIDEK.COM 800-364-0287 <br />IMPERVIOUS SURFACE <br />POLYURETHANE SEALANT FORTIFIBER MOISTOP SEALANT OR APPROVED EQUAL. <br />AT A MINIMUM, EXPOSED SEALANT SHALL BE CHECKED ANNUALLY AND <br />MAINTAINED PER MANUFACTURERS RECOMMENDATION TO MAINTAIN A WATER <br />TIGHT SEAL. <br />CORNER FLASHING MEMBRANE WITH A RUBBERIZED ASPHALT CORE <br />TLS LABS. GS 100 SERIES OR APPROVED EQUAL <br />NOTE: <br />CAULK ENDS OF THRESHOLDS, AND UNDER FULL LENGTH OF LEGS <br />TO DOOR FLASHING PAN TO MAINTAIN WATER TIGHT INSTALLATION. <br />W.R.B.WEATHER RESISTIVE BARRIER (W.R.B.), TWO -PLY WEATHER TEX BY FORTIFIBER <br />BUILDING SYSTEMS GROUP. SUPER JUMBO TEX 60 MINUTE BUILDING PAPER OVER <br />WEATHERSMART HOUSE WRAP. <br />S.A.F. <br />FLASHING MULTI-LAYERED COMPOSITE POLYOLEFIN FLASHING 12" WIDE (U.N.O.) <br />FORTIFIBER MOISTOP NEXT OR APPROVED EQUAL <br />SEALANT <br />CORNER FLASH <br />SELF ADHESIVE, HEALING FLASHING (S.A.F.) 12" WIDE (U.N.O.) 25 MIL (U.N.O.) <br />FORTIFIBER FORTIFLASH OR APPROVED EQUAL. ADHERE S.A.F. TO CLEAN, DUST <br />FREE BACKING USING CHEMICALLY COMPATIBLE MATERIALS AND/OR PRIMERS. <br />PROVIDE SOLID WOOD BACKING OR SHEATHING BEHIND ALL AREAS TO RECEIVE <br />SELF ADHESIVE, HEALING FLASHING. <br />GSM FLASHING METAL SHALL BE SHOP FABRICATED USING A MINIMUM 26 GA. <br />BONDERIZED GALVANIZED SHEET METAL WITH SOLDERED JOINTS U.N.O.. STUCCO <br />ACCESSORIES SHALL BE CEMCO WATER MANAGEMENT SERIES, 25 GA. MATERIAL <br />WITH A G-90 GALVANIZED COATING OR ARCHITECT APPROVED EQUAL, UNLESS <br />NOTED OTHERWISE. <br />GSM FLASHING <br />BOND BREAKER POLYETHYLENE TAPE TO BE USED AS BOND BREAKER, REQUIRED BETWEEN <br />ACRYLIC PLASTER AND PAINT FINISHES AND ALL WEEPING SOLID LEG FLASHING. <br />TAPE SHOULD RUN FROM THE SOLID VERTICAL LEG TO 1/8" FROM FRONT EDGE. <br />ANY APPLIED FINISH THAT CREATES A BOND BETWEEN THE PLASTER AND METAL <br />SHALL BE BROKEN WITH UTILITY KNIFE AND SHALL BE MAINTAINED AS SUCH. <br />18 & 22 <br />- <br />18 & 22 <br />- <br />DOOR FLASHING INSTALLATION <br />SCALE: N.T.S.FILE NAME: <br />CEMCO #3 - INSTALL FLASHING SCREED AS REQUIRED BY DETAIL. EXTEND THE SCREED 2" PAST <br />THE ROUGH OPENING AT BOTH ENDS. SET SCREED ONTO HEAD PLASTER MOULD WITH SEALANT. <br />NOT REQUIRED IF THE DOOR IS PROTECTED BY A MINIMUM 30" DEEP EAVE OR SOFFIT THAT IS <br />WITHIN 24" OF THE DOOR HEAD, THE EAVE OR SOFFIT SHALL EXTEND 30" EACH SIDE OF DOOR . <br />CEMCO #3 - SET FLASHING SCREED IN <br />SEALANT TO PLASTER MOULD HEAD. <br />W.R.B. - APPLY W.R.B. IN WEATHERBOARD FASHION AROUND THE INSTALLED DOOR. <br />JAMB S.A.F <br />2 <br />STEP <br />3 <br />3 <br />STEP 4 <br />5STEP <br />STEP <br />2" <br />B <br />A <br />STEP 6A <br />ROUG <br />H <br /> <br /> <br /> <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />W <br />I <br />D <br />T <br />H <br /> <br />P <br />L <br />U <br />S <br /> <br />4 <br />" <br />FLASHING PAN - INSTALL ALONG BOTTOM OF OPENING, SET IN SEALANT AND FASTEN THROUGH <br />THE VERTICAL LEGS ONLY TO THE ROUGH FRAMING JAMBS. <br />SETTING SEALANT - APPLY A CONTINUOUS 1/2" BEAD OF SEALANT TO THE BACK SIDES OF THE DOOR <br />FRAME PLASTER MOULD. PLACE THE DOOR IN THE ROUGH OPENING, SEALANT SHOULD OOZE OUT <br />BETWEEN THE PLASTER MOULD AND THE HEAD AND JAMB S.A.F.; TOOL SEALANT. PLUMB AND <br />SQUARE THE DOOR THEN FASTEN THE DOOR FRAME TO THE JAMB STUDS. AFTER INSTALLING THE <br />DOOR, APPLY LOW EXPANSION FOAM BETWEEN THE DOOR FRAME AND THE ROUGH OPENING. <br />JAMB S.A.F. - ATTACH A STRIP OF S.A.F. ALONG EACH SIDE OF THE ROUGH OPENING. ALIGN THE <br />S.A.F. WITH THE FRAMING EDGE OF THE ROUGH OPENING. THE S.A.F. SHALL OVERLAP THE "L" <br />METAL AND PAN FLASHING BY 3" AND EXTEND 12" ABOVE THE HEAD ROUGH OPENING. <br />PAN FLASHING* - SOLDER ALL JOINTS. <br />WHEN "L" FLASHING HAS LESS THAN A 2" <br />VERTICAL RISE BETWEEN THE DECK AND <br />PAN, CONSTRUCT PAN AND "L" FLASHING <br />AS INTEGRAL ONE PIECE. COORDINATE <br />PAN DEPTH AND LIP HEIGHT WITH EACH <br />SPECIFIC THRESHOLD, FABRICATE PAN <br />TO MAXIMIZE DEPTH YET ELIMINATE <br />THRESHOLD ANCHOR PENETRATIONS <br />THROUGH THE PAN. <br />3" <br />4" LA <br />P <br />4" <br />4" <br />4" <br />4" <br />COOR <br />D <br />I <br />N <br />A <br />T <br />E <br />WITH <br />T <br />H <br />R <br />E <br />S <br />H <br />O <br />L <br />D <br /> <br /> <br /> <br /> <br /> <br /> <br />1 <br />/ <br />8 <br />" <br /> <br /> <br />M <br />I <br />N <br />LIP <br />ROU <br />G <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />- <br /> <br />1 <br />/ <br />8 <br />" <br />2" <br />* USE STAINLESS STEEL "L" AND PAN FLASHING AT CONCRETE SLAB OR DECK. COAT <br />4" <br />2" <br />4" <br />LAP <br />TYP <br />4" <br />LAP <br />TYP <br />VE <br />R <br />I <br />F <br />Y <br />4" <br />ROU <br />G <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />W <br />I <br />D <br />T <br />H <br />WEEP S.A.F. - ADHERE 9" WIDE S.A.F. OVER CEMCO #3 FLASHING SCREED. EXTEND THE S.A.F. 2" <br />PAST THE CEMCO #3 FLASHING SCREED AT BOTH ENDS; S.A.F. REQUIRED WITH CEMCO #3. <br />STEP <br />STEP <br />STEP 4 <br />STEP 1 <br />6B <br />2STEP <br />6A <br />STEP <br />SECTION BB <br />A <br />B <br />6BSTEP WEEP S.A.F. - ADHERE O/ CEMCO #3 <br />FLASHING SCREED. <br />3 <br />12 <br />" <br />ROUGH OPENING WIDTH PLUS 26" <br />HEAD S.A.F. <br />ADHERED <br />JAMB S.A.F. <br />FLASHING PAN <br />ATTACH FLASHING PAN <br />AT VERTICAL SIDES ONLY <br />ROUGH OPENING WIDTH <br />BACK PRIME DOOR <br />FRAME AND PLASTER <br />MOULD PRIOR TO <br />SETTING DOOR <br />STEP 7 <br />VE <br />R <br />I <br />F <br />Y <br />F.F. <br />ROUG <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />W <br />I <br />D <br />T <br />H <br /> <br />P <br />L <br />U <br />S <br /> <br />2 <br />6 <br />" <br />2"ROUG <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />W <br />I <br />D <br />T <br />H <br /> <br />P <br />L <br />U <br />S <br /> <br /> <br /> <br />8 <br />" <br />STEP SETTING SEALANT - APPLY 1/2" BEAD <br />TO BACK SIDES OF DOOR FRAME <br />PLASTER MOULD. BACK PRIME DOOR <br /> FRAME AND PLASTER MOULD PRIOR TO <br /> APPLYING THE SETTING SEALANT <br />2" <br />STEP HEAD S.A.F4 <br />STEP <br />STEP <br />1 <br />HEAD S.A.F. - ADHERE S.A.F. ABOVE THE ROUGH OPENING. EXTEND THE S.A.F. 13" PAST THE ROUGH <br />OPENING AT EACH END. ALIGN THE BOTTOM OF THE S.A.F. WITH THE ROUGH OPENING HEAD. <br />"L" METAL - INSTALL AT DECK TO WALL TRANSITION, PROVIDE SOLID BACKING AT VERTICAL LEGS <br />AND INSTALL WITH A MINIMUM 4" LAP BETWEEN PIECES. <br />12" <br />5 <br />2 <br />SECTION AA <br />STEP "L" FLASHING* <br />1 <br />- <br />4 <br />- <br />EXTERIOR DOOR THRESHOLD - 1ST FL. <br />SCALE: 3"=1'-0"FILE NAME: <br />EXTERIORINTERIOR <br />2"LANDING SLOPE <br />1/4" = 1'-0" MAX <br />EXTERIOR DOOR PER PLAN <br />DOOR FRAME WITH INTEGRAL STOP <br />FACE OF WALL BEYOND <br />DOOR BOTTOM "PEMKO" 234AV OR <br />APPROVED EQUAL <br />PATIO SLAB OR CONC. STOOP <br />CEMCO #7 EXTENDED <br />FOUNDATION SCREED AT WALL <br />BEYOND WITH 2" LONG EXTENSION <br />INTERIOR FINISH FLOORING <br />"PENKO" ALUMINUM THRESHOLD OR <br />APPROVED EQUAL SET IN <br />CONTINUOUS BEAD OR SEALANT <br />FOR ADDITIONAL INFORMATION SEE DETAILS <br />1/2" EXPANSION JOINT FILLER <br />CONCRETE ANCHOR, PROVIDE THREE <br />ANCHORS MINIMUM OR OPTIONAL <br />2x PRESSURE TREATED SLEEPER <br />STAINLESS STEEL THRESHOLD PAN SET <br />IN CONTINUOUS BEADS OF SEALANT <br />PE <br />R <br /> <br />P <br />L <br />A <br />N <br />4" <br /> <br />T <br />Y <br />P <br />. <br />7- <br />3 <br />/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />8 <br />- <br />13 <br />- <br />FLUSH DOOR AT STUCCO <br />SCALE: 3"=1'-0"FILE NAME: <br />SHEATHING MAY OCCUR <br />HEADER PER STRUCTURAL <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />W.R.B. O/ 9" WIDE WEEP S.A.F. <br />O/ CEMCO #3 FLASHING SCREED <br />O/ DOOR HEAD S.A.F. <br />2x SOLID BACKING REQUIRED <br />AT S.A.F. WHEN SHEATHING <br />NOT PROVIDED <br />SHEATHING MAY OCCUR <br />2x SOLID BACKING REQUIRED AT S.A.F. <br />WHEN SHEATHING NOT PROVIDED <br />DOOR AND FRAME PER DOOR <br />SCHEDULE <br />HEAD <br />JAMB <br />PLASTER MOULD O/ SEALANT O/ <br />S.A.F. O/ DOOR HEAD W/ BEAD OF <br />SEALANT AT HEAD AND MOULD <br />DOOR AND FRAME PER DOOR <br />SCHEDULE <br />CEMCO #3 FLASHING SCREED, WHEN <br />REQUIRED BY DETAIL 3 THIS SHEET. <br />SET IN SEALANT OVER PLASTER MOULD <br />EXTERIOR CEMENT PLASTER <br />O/ WIRE LATH O/ W.R.B. <br />PERIMETER GASKET <br />"PEMKO" 303DV OR <br />APPROVED EQUAL <br />9" WIDE JAMB S.A.F. DOWN O/ DOOR <br />FLASHING PAN AND "L" METAL <br />5/8" GYPSUM WALLBOARD FINISH <br />LOW EXPANSION FOAM <br />APPLY WITHIN SHIM CAVITY <br />PERIMETER GASKET "PEMKO" <br />303DV OR APPROVED EQUAL <br />PLASTER MOULD O/ SEALANT O/ <br />S.A.F. O/ DOOR JAMB W/ BEAD OF <br />SEALANT AT JAMB AND MOULD <br />VERIFY FRAME <br />WIDTH WITH <br />WALL REQ'MT. <br />5/8" GYPSUM WALLBOARD FINISH <br />FRAMING PER STRUCTURAL <br />FRAMING PER STRUCTURAL <br />LOW EXPANSION FOAM <br />APPLY WITHIN SHIM CAVITY <br />1/ <br />4 <br />" <br />1 <br />- <br />4 <br />- <br />FOR ADDITIONAL INFORMATION SEE DETAILS 8 <br />- <br />13 <br />- <br />THRESHOLD PAN FLASHING <br />SCALE: 1 1/2"=1'-0"FILE NAME: <br />4" <br />1/4" <br />4"4" <br />2" <br />SEE THRESHOLD <br />DETAIL <br />26 GA. BONDERIZED GALV. <br />MTL. THRESHOLD FLASHING <br />UNDER DOOR THRESHOLD <br />SET FLASHING ON CONT. BED <br />OF SEALANT AT HEEL <br />HEEL FLASHING <br />WEATHERBOARD LAP BUILDING <br />PAPER, SCREEDS AND FINISHES <br />OVER HEEL FLASHING <br />UPTURN BACK <br />EDGE AT 45° <br />DEGREES <br />NOTE: SOLDER ALL JOINTS WATERTIGHT <br />26 GA. BONDERIZED GALV. MTL. <br />VARIES. VERIFY W/ <br />THRESHOLD DETAIL. <br />3" LAP MIN. <br />SET ON CONT. <br />BED OF <br />SEALANT <br />18 <br />1 <br />APPLY FOUR CONTINUOUS <br />3/8" BEADS OF CAULK <br />DIRECTLY TO THE SLAB FOR <br />THE DOOR THRESHOLD OR <br />SUBFLOOR WHERE THE SILL <br />PAN WILL BE INSTALLED. <br />EXTEND BEADS OF CAULK <br />MINIMUM 4" UP JAMB <br />FRAMING <br />SILL PAN <br />2 <br />AT SECOND FLOOR AND UNPROTECTED <br />DOORWAYS INSTALL THE SILL PAN PER <br />MANUFACTURER'S SPECIFICATIONS. <br />GLUE THE OVERLAPPING SILL PAN <br />JOINTS USING PVC CEMENT ONLY. THE <br />PAN MUST BE PLACED ON A BEAD OF <br />CAULK TO REDUCE AIR INFILTRATION. <br />THE VERTICAL ENDS OF THE SILL PAN <br />FLASHING, BOTH FACE AND JAMB, MUST <br />BE TAPED TO THE FRAMING. <br />3 <br />12" BASE FLASHING IS ALREADY <br />INSTALLED ON THE BACKSIDE OF THE <br />STUCCO MOLD. <br />4 <br />INSTALL THE DOOR UNIT INTO THE <br />ROUGH OPENING WITH THE ATTACHED <br />FLASHING FLANGE. CHECK TO ENSURE <br />THE DOOR IS PLUMB, SQUARE, AND <br />OPERATES PROPERLY. <br />5 6 <br />IF STUCCO OR MANUFACTURED STONE <br />IS SPECIFIED, INSTALL A WEEP SCREED <br />WITH A MINIMUM OF 3-1/2" LEG HEIGHT. <br />7 <br />INSTALL THE FIRST COURSE OF THE <br />FIRST LAYER OF BUILDING PAPER <br />UNDER THE BASE FLASHING AT THE <br />SILL. <br />9 <br />APPLY A 4" STRIP OF DOOR FLASHING <br />TAPE OVER THE BUILDING PAPER, <br />STARTING AT THE TOP OF THE HEAD <br />BASE FLASHING TO THE BOTTOM OF <br />SILL FLASHING. <br />PRODUCT <br />SPECIFICATIONS <br />REQUIRED PRODUCTS: <br />* BUILDING PAPER - GRADE 'D' 60 MINUTE BUILDING PAPER MUST MEET 60 MINUTES OR GREATER WATER <br />RESISTANCE PER ASTM D-779 TESTING, WATER VAPOR TRANSMISSION 11 PERMS OR GREATER PER <br />ASTM E-96 TESTING AND TENSILE STRENGTH 45 LB-FT/IN PER ASTM D-828 TESTING. <br />* LOW EXPANSION FOAM <br />* DOW WINDOW & DOOR 1000 <br />* FOMO HANDI-SEAL WINDOW AND DOOR STRAW FOAM SEALANT <br />* TOUCH 'N FOAM NOWARP WINDOW & DOOR SEALANT <br />* DRIP CAP (NOT REQUIRED ON STUCCO CLAD ASSEMBLIES) - GALVANIZED OR ALUMINUM DRIP CAP AT <br />SIDING ASSEMBLIES <br />* FLASHING TAPE - 4" DOW WEATHERMATE STRAIGHT FLASHING OR EQUIVALENT BUTYL TAPE <br />* BASE FLASHING - 9" NON-SELF STICK FLASHING MATERIAL POLYOLEFIN FILM WITH LAMINATED <br />FIBERGLASS SCRIM REINFORCEMENT <br />* FLASHING AT CONCRETE - RUBBER OR NEOPRENE MEMBRANE <br />* SILL PAN - PREFORMED PLASTIC SILL PAN IS REQUIRED <br />* THRESHOLD SEALANT (SILL PAN ALTERNATIVE) - ADCO B-100 BUTYL RUBBER SEALANT <br />* CAULK - MUST MEET ASTM SPECIFICATION C920 CLASS 25 <br />* CEMENT - PVC CEMENT FOR THE SILL PAN (NOTE: ALL PURPOSE GLUE IS PROHIBITED) <br />DEPENDENCIES PREREQUISITE: <br />* FRAMING MUST BE COMPLETE WITH ALL SHEAR PANELS INSTALLED <br />* 12" BASE FLASHING PRE-ATTACHED TO BACK SIDE OF STUCCO MOLD <br />POST REQUISITE: <br />* BUILDING PAPER INSTALLED AS A BOND BREAK FOR BRICK, STUCCO OR STONE <br />11 <br />FINISH INSTALLING THE FIRST LAYER OF <br />BUILDING PAPER AT THE HEAD OF THE <br />DOOR, ENSURING IT IS LAPPED SHINGLE <br />FASHION. THIS COURSE MAY BE LAPPED <br />MORE THAN THE TYPICAL 4"-6", AS IT <br />MUST TOUCH THE FRAME OF THE DOOR <br />AT THE HEAD. NO VERTICAL LAPS <br />SHOULD OCCUR ABOVE THE DOOR OR <br />WITHIN 24" OF THE FRAME ON EITHER <br />SIDE. <br />12 <br />AFTER REMOVING THE SHIMS, APPLY A BEAD OF <br />LOW-EXPANSION FOAM BETWEEN THE DOOR <br />FRAME AND THE SIDES AND TOP OF THE ROUGH <br />OPENING. <br />1" FOLD ADHERED TO <br />TOP OF TRIM <br />NOTE: MAKE SURE THAT THE WEEP <br />SCREED EXTENDS AT LEAST 1" PAST <br />THE FRAME TO FOUNDATION <br />TRANSITION. <br />8 <br />CONTINUE TO INSTALL ADDITIONAL <br />COURSES OF THE FIRST LAYER OF <br />BUILDING PAPER ENSURING IT IS <br />LAPPED SHINGLE FASHION, <br />MAINTAINING A 4" MINIMUM OVERLAP <br />HORIZONTALLY AND 6" VERTICALLY. THE <br />BUILDING PAPER SHALL BE INSTALLED <br />OVER THE FLASHING AT THE JAMBS AND <br />SHALL BE CUT 2" FROM THE EDGE OF <br />THE FLOOR. <br />DO NOT COVER THE HEAD OF THE DOOR <br />YET. <br />NOTE: REFER TO THE SCOPE OF WORK FOR RECOMMENDED PRODUCTS <br />CAULK <br />TAPE FASTEN WITH <br />A STAPLE <br />EXTERIOR SIDE <br />BASE FLASHING <br />INSTALLED BY <br />DOOR SUPPLIER <br />INTERIOR <br />EXTERIOR <br />12" BASE FLASHING <br />12" BASE FLASHING <br />APPLY A STRIP OF BASE FLASHING <br />OVER THE DOOR HEAD. EXTEND THE <br />HEAD FLASHING HORIZONTALLY TO THE <br />NEAREST STUD AND FASTEN. THIS WILL <br />PREVENT THE HEAD FLASHING FROM <br />ROLLING INTO THE STUD CAVITY. <br />NOTE: IF THE FINISH CLADDING IS <br />SIDING, REFER TO STEPS 13 AND 14 <br />THAT DESCRIBE THE DRIP CAP <br />APPLICATION. <br />INTERIOR <br />EXTERIOR <br />12" BASE <br />FLASHING <br />WEEP SCREED <br />FIRST COURSE <br />BUILDING PAPER <br />BUILDING PAPER CUT 2" <br />FROM THE EDGE OF THE DOOR. <br />ADDITIONAL BUILDING <br />PAPER COURSES. <br />4" FLASHING TAPE ADHERED TO THE BUILDING <br />PAPER. APPLY WITH SQUEEGEE TO ENSURE <br />PROPER ADHESION. <br />10 <br />APPLY A 4" STRIP OF DOOR FLASHING <br />TAPE OVER THE 12" BASE FLASHING AT <br />THE HEAD OF THE DOOR AND EXTEND <br />APPROXIMATELY 1" BEYOND THE 4" <br />STRIPS OF DOOR FLASHING AT THE <br />SIDES OF THE DOOR. <br />1" <br />TAPE <br />FOAM <br />13 <br />IF SIDING OR MANUFACTURED STONE IS <br />SPECIFIED, CUT AND INSTALL <br />APPROPRIATE SIZED DRIP CAP OVER <br />THE DOOR HEAD. <br />DRIP CAP <br />14 <br />APPLY 4" DOOR FLASHING TAPE OVER <br />DRIP CAP. <br />4" DOOR FLASHING TAPE <br />DOOR FLASHING SEQUENCE <br />SCALE: 1/2"=1'-0"FILE NAME: <br />16NOT USEDNOT USED NOT USED <br />23NOT USED <br />NOT USED <br />EXTERIOR DOOR THRESHOLD - 2ND FL. <br />SCALE: 3"=1'-0"FILE NAME: <br />"PEMKO" 274D SADDLE SET IN <br />SEALANT PER MANUFACTURER <br />3 THRESHOLD ANCHORS, DO NOT <br />PENETRATE FLASHING PAN <br />CEMTENTITIOUS WATERPROOF <br />DECK MEMBRANE <br />FOR ADDITIONAL INFO, <br />REFER TO DETAILS <br />1 <br />- <br />SLOPE SUBSTRATE <br />1/4" = 1'-0" MAX <br />SHEATHING PER STRUCTURAL <br />EXTERIOR DOOR PER PLAN <br />DOOR FRAME WITH INTEGRAL STOP <br />FACE OF WALL BEYOND <br />DOOR BOTTOM "PEMKO" 345D OR <br />APPROVED EQUAL <br />CEMCO #7 EXTENDED FOUNDATION <br />SCREED AT WALL BEYOND WITH 1-1/2" <br />LONG EXTENSION <br />INTERIOR FINISH FLOOR <br />FLOORING 1/4" TO 1/2" THICK <br />THRESHOLD STOP, "PEMKO" 1842DS <br />OR APPROVED EQUAL SET IN <br />CONTINUOUS BEAD OR SEALANT <br />1/ <br />8 <br />" <br /> <br />S <br />A <br />D <br />D <br />L <br />E <br /> <br />T <br />O <br />DO <br />O <br />R <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br />2" <br />24 GA. STAINLESS STEEL <br />THRESHOLD PAN WITH 1/2" BACK <br />DAM AND 4" END WALL FLANGES SET <br />IN FULL SEALANT BED <br />SEAL FASTENERS AT THRESHOLD. <br />8 <br />- <br />4 <br />- <br />13 <br />- <br />HOLD- 829 N <br />Garfield St1/15/2025