My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD- 829 N Garfield St - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Garfield St
>
829 N Garfield St
>
HOLD- 829 N Garfield St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:36 PM
Creation date
6/1/2025 12:11:15 PM
Metadata
Fields
Template:
Plan
Permit Number
20583473
20583704
30547537
40539325
105120166
Full Address
829 N Garfield St
829 N Garfield St Unit# 1
Permit Number (Not in SAPIN)
20583408
20583409
20583410
20583411
20583412
20583413
20583414
20583416
20583417
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:25 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
T.O.PLATE <br />T.O.SHTG <br />8' <br />- <br />3 <br />" <br />+/ <br />- <br /> <br />6 <br />' <br />- <br />6 <br />" <br />6' <br />- <br />8 <br />" <br />WDW. HDR. <br />T.O.PLATE <br />T.O.SHTG <br />8' <br />- <br />3 <br />" <br />6' <br />- <br />8 <br />" <br />WDW. HDR. <br />+/ <br />- <br /> <br />2 <br />4 <br />' <br />- <br />0 <br />" <br />UTILITY PRIVATE <br />GARAGES <br />UNIT 5UNIT 1 <br />UNIT 6 <br />UNIT 3 <br />UNIT 7 UNIT 8 <br />UNIT 4 <br />UNIT 10 <br />STAIR <br />#2 <br />W1W1 <br />W2 W2W2W2 <br />W2 W2 <br />T.O.ROOF <br />12 <br />3 <br />12 <br />3 <br />1 <br />TYP. <br />3 <br />TYP. <br />2 <br />TYP. <br />4 <br />TYP. <br />7 <br />TYP. <br />6 <br />TYP. <br />9 <br />TYP. <br />11 <br />TYP. <br />5 <br />TYP. <br />10 <br />TYP. <br />09 <br />A901 <br />TYP. <br /> FC1 <br /> FC2 <br /> FC3 <br /> FC1 <br /> FC2 <br /> FC3 <br /> FC1 <br /> FC2 <br /> FC3 <br /> FC1 <br /> FC2 <br /> FC3 <br />ALT.1 <br />ALT.2 <br />ALT.1 <br />ALT.2 <br />ALT.1 <br />ALT.2 <br />ALT.1 <br />ALT.2 <br /> FC3 FC3 <br /> W2A W2A <br /> W2A W2A <br /> W2A <br />T.O.PLATE <br />T.O.SHTG <br />8' <br />- <br />3 <br />" <br />+/ <br />- <br /> <br />6 <br />' <br />- <br />6 <br />" <br />6' <br />- <br />8 <br />" <br />WDW. HDR. <br />T.O.PLATE <br />T.O.SHTG <br />8' <br />- <br />3 <br />" <br />6' <br />- <br />8 <br />" <br />WDW. HDR. <br />+/ <br />- <br /> <br />2 <br />4 <br />' <br />- <br />0 <br />" <br />GARAGES 6-10 GARAGES 1-5 UNIT 2 <br />UNIT 6 <br />UNIT 3 <br />UNIT 7UNIT 8 <br />UNIT 4 <br />UNIT 9 CORRIDOR <br />W1W1 W2 W2 <br />W2 W2W2 <br />T.O.ROOF <br />1 <br />TYP. <br />3 <br />TYP. <br />12 <br />3 <br />12 <br />3 <br />2 <br />TYP. <br />11 <br />TYP. <br />7 <br />TYP. <br />6 <br />TYP. <br />4 <br />TYP. <br />5 <br />TYP. <br />10 <br />TYP. <br />8 9 <br />TYP. <br />09 <br />A901 <br />TYP. <br /> FC1 <br /> FC2 <br /> FC3 <br />ALT.1 <br />ALT.2 <br /> FC1 <br /> FC2 <br /> FC3 <br />ALT.1 <br />ALT.2 <br /> FC1 <br /> FC2 <br /> FC3 <br />ALT.1 <br />ALT.2 <br /> FC1 <br /> FC2 <br /> FC3 <br />ALT.1 <br />ALT.2 <br /> FC3 FC3 <br /> W2A W2A <br /> W2A <br /> W2A <br /> W2A <br />T.O.PLATE <br />T.O.SHTG <br />8' <br />- <br />3 <br />" <br />+/ <br />- <br /> <br />6 <br />' <br />- <br />6 <br />" <br />6' <br />- <br />8 <br />" <br />WDW. HDR. <br />T.O.PLATE <br />T.O.SHTG <br />8' <br />- <br />3 <br />" <br />6' <br />- <br />8 <br />" <br />WDW. HDR. <br />+/ <br />- <br /> <br />2 <br />4 <br />' <br />- <br />0 <br />" <br />UNIT 3 <br />UNIT 7 <br />W1 <br />W1 W1 <br />W1 <br />T.O.ROOF <br />12 <br />3 <br />12 <br />3 <br />1 <br />TYP. <br />3 <br />TYP. <br />2 <br />TYP. <br />4 <br />TYP. <br />7 <br />TYP. <br />6 <br />TYP. <br />10 <br />TYP. <br />5 <br />TYP. <br />9 <br />TYP. <br />01 <br />A901 <br />TYP. <br /> FC1 <br /> FC2 <br /> FC3 <br />ALT.1 <br />ALT.2 <br /> FC3 <br />SCALE:33/16"=1'-0"TRANSVERSE SECTION C <br />BUILDING SECTIONS <br />A400 <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />Zohrabians Art of Design <br />700 Palm Drive, Suite 106 <br />Glendale, CA 91202 <br />zartofdesign.com <br />818.300.9420 <br />4t <br />h <br /> <br />P <br />l <br />a <br />n <br /> <br />C <br />h <br />e <br />c <br />k <br /> <br />S <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l <br />No.Date Description <br />06/05/2024 100% DD SET <br />06/14/2024 50% CD PROGRESS SET <br />06/21/2024 75% CD PROGRESS SET <br />07/02/2024 NEIGHBORHOOD REVIEW <br />07/10/2024 1ST PLAN CHECK SUBMITTAL <br />09/13/2024 2ND PLAN CHECK SUBMITTAL <br />11/07/2024 3RD PLAN CHECK SUBMITTAL <br />12/18/2024 4TH PLAN CHECK SUBMITTAL <br />82 <br />9 <br /> <br />N <br />. <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Santa Ana, CA 92701 <br />829 N. Garfield Street <br />Name: <br />Project Contact: <br />Phone: <br />Email: <br /> <br />Principal: <br />Z.AOD Project No:2024-02 <br />Arthur Zohrabians <br />818.300.9420 <br />Arthur Zohrabians <br />info@zartofdesign.com <br />Phone No.:949.922.7075 <br />Email:vanitapuri@gmail.com <br />Owner <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />Address: <br />Ren.11/30/25 <br />A <br />No. C37490 <br />A <br />A FOILOFC <br />R <br />INTA <br />S <br />ET <br />TC <br />A RCHITE <br />DESNECIL <br />RTHUR <br />HAMAYAK ZOHRABI <br />A <br />SN <br />VVS Estates, LLC <br />1 <br />Vanita Soni PuriAttn: <br />2 <br />3 <br />SCALE:13/16"=1'-0"LONGITUDINAL SECTION A <br />SCALE:23/16"=1'-0"LONDITUDINAL SECTION B <br />BLDG. SEC. SYMBOL LEGEND <br />2X4 WOOD STUD WALL <br />* REFER TO W1e & W2e / A900 FOR (E) ASSEMBLIES <br /> REFER TO W1 & W2 / A900 FOR (PPSD) ASSEMBLIES <br /> REFER TO "FIRE-RESISTANCE NOTES" <br />BLDG. SECTION KEYNOTES <br />DESCRIPTION ( NOT ALL NOTES APPLY TO DRAWING) <br />1 (E) CONVENTIONAL 2x ROOF FRAMING @ 16" O.C. <br />REFER TO STRUCT'L DWGS. <br />2 (E) CONVENTIONAL 2x ATTIC FRAMING @ 16" O.C. <br />REFER TO STRUCT'L DWGS. <br />3 (E) CONVENTIONAL 2x FLOOR FRAMING @ 16" O.C. <br />REFER TO STRUCT'L DWGS. <br />4 (E) CONVENTIONAL 2x SUBFLOOR FRAMING @ 16" O.C. <br />REFER TO STRUCT'L DWGS. <br />5 R-11 INSULATION AT EXTERIOR WALLS. REFER TO THE ENERGY <br />CALCULATIONS ON SHEETS TM00 - TM01 OF THE MECH'L DWGS. <br />6 FIRE-RES. RATED WALL ASSEMBLY. REFER TO WALL TAGS. <br />7 FIRE-RES. RATED FLOOR / CEILING OR ROOF / CEILING ASSEMBLY. <br />REFER TO WALL TAGS. <br />8 (PPSD) WOOD SHEAR WALL. REFER TO STRUCT'L DWGS. <br />9 (E) EXTERIOR FINISH. REFER TO SHEET A300. <br />10 (E) CRAWL SPACE W/ PERIMETER FOUNDATION AT UNITS. <br />11 (E) CONCRETE SLAB ON GRADE AT UTILITY ROOM & GARAGES. <br />FIRE-RESISTANCE NOTES <br />2X4 WOOD STUD WALL ( 1-HR FIRE-RES. REQ * ) <br />FIRE-RES. RATED WALL REFERENCES. <br />REFER TO SHEET A900.W # <br />1.REFER TO SHEET A900 FOR FIRE-RES. RATED WALL & FLOOR / <br />CEILING ASSEMBLIES. REFER TO WALL TAGS ON SHEETS A201 & <br />A202 FOR LOCATIONS OF FIRE-RES. RATED WALL ASSEMBLIES. <br />2.REFER TO SHEET A901 FOR FIRE-RES. RATED CONTINUITY DETAILS. <br />3.REFER TO SHEET A902 FOR TYPICAL FIRE-RES. RATED DETAILS. <br />4.REFER TO SHEET A903 FOR FIRE-RES. RATED PENETRATION <br />DETAILS. <br />5.WHERE PORTIONS OF EXISTING WALL FINISHES ARE REMOVED <br />DURING CONSTRUCTION TO ACHIEVE THE ALTERATIONS <br />PROPOSED, THOSE PORTIONS SHALL BE REPLACED WITH THE <br />PROPOSED WALL ASSEMBLIES, REFERENCED ON SHEETS A201 & <br />A202, & DETAILED ON SHEET A900, FOR THE LENGTH OF EACH <br />FRAMING BAY THAT IS EXPOSED UP TO THE NEAREST STUD IN <br />EACH DIRECTION. <br />6.WHERE EXISTING WALL FRAMING MEMBERS ARE REPLACED WITH <br />NEW WALL FRAMING MEMBERS AT DEMISING WALLS BETWEEN <br />UNITS, RESILIENT CHANNELS SHALL BE ADDED TO ACHIEVE A MIN. <br />STC RATING OF 50, PER DETAIL W2A / A900. <br />7.THE EXISTING FLOOR / CEILING ASSEMBLIES BELOW THE 2ND <br />FLOOR UNITS AND EXTERIOR CORRIDORS, AND THE ROOF / <br />CEILING ASSEMBLIES ABOVE THE 2ND FLOOR, SHALL BE <br />IMPROVED TO 1-HR OF FIRE-RESISTANCE PER THE FLOOR / <br />CEILING AND ROOF / CEILING ASSEMBLIES REFERENCED ON <br />THIS SHEET AND DETAILED ON SHEET A900. <br />8.BUILT-IN FIXTURES, SUCH AS ELECTRICAL SERVICE SUBPANELS, <br />EXCEEDING 16 SQ. IN. IN AREA SHALL BE FIRE-RES. RATED. <br />BUILDING SECTION NOTES <br />1.ALL VERTICAL DIMENSIONS SHOWN ARE FROM TOP OF WOOD <br />SHEATHING AT 1ST & 2ND FLOOR. <br />2.REFER TO DETAIL SHEETS A900-A903 FOR FIRE-RESISTANCE <br />RATED DETAILS AND NOTES. <br />3.REFER TO DETAIL SHEETS A910-A912 FOR MINIMUM WINDOW, <br />DOOR AND WALL VENT MOISTURE BARRIER INSTALLATION <br />REQUIREMENTS. <br />4.ALL WINDOW HEADS SHALL BE SET AT THE SAME HEIGHT AS THE <br />ENTRY DOOR (+/- 6'-8") U.N.O. <br />5.ALL RENOVATED EXTERIOR WALLS SHALL BE SOLID SHEATHED W/ <br />EXTERIOR GRADE PLYWOOD, SAME THICKNESS AS EXTERIOR <br />SHEAR WALLS. REFER TO STRUCTURAL DRAWINGS FOR SHEAR <br />WALL LOCATIONS. <br />6.PROVIDE (2) LAYERS OF MIN. GRADE "D" BUILDING PAPER AT <br />WOOD SHEATHED WALLS RECEIVING EXTERIOR CEMENT PLASTER. <br />7.ALL STUD WALLS & CEILINGS EXTENDING INTO A SOFFIT WILL BE <br />PREBOARDED WITH GYP.BD. PRIOR TO SOFFIT INSTALLATION. <br />8.ALL STEEL FABRICATIONS SHALL HAVE ENDS CAPPED. <br />9.ALL WELDS SHALL BE GROUND SMOOTH AND GALVANIZED OR <br />SHOP-PRIMED FOR THE APPLICATION OF PAINT. <br />10.DUCT TERMINATIONS TO OCCUR MIN. 10'-0" FROM WINDOW OR <br />DOOR OPENINGS IF IN THE SAME PLANE OR LOWER AND 10'-0" + 3" <br />PER DEGREE FROM HORIZONTAL WHEN ABOVE, PER 2022 CMC <br />SEC. 510.9.2.1. <br />FIRE-RES. RATED FLOOR / CEILING OR ROOF / CEILING <br />ASSEMBLY REFERENCES. REFER TO SHEET A900.FC # <br />2X WOOD FLR. / CLG. OR ROOF / CLG. ASSEMBLY <br />** REFER TO FCe / A900 FOR (E) ASSEMBLY <br /> REFER TO FC1 - FC3 / A900 FOR (PPSD) ASSEMBLIES <br /> REFER TO "FIRE-RESISTANCE NOTES" <br />2X WOOD FLR. / CLG. OR ROOF / CLG. ASSEMBLY <br />( 1-HR FIRE-RES. REQ ** ) <br />3 <br />3 <br />3 <br />3 <br />3 3 <br />3 3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />33 <br />3 <br />3 <br />HOLD- 829 N <br />Garfield St1/15/2025
The URL can be used to link to this page
Your browser does not support the video tag.