Laserfiche WebLink
PV-2REV: A 8/30/2024 <br />CONSUELO SMITH <br />931 W 18TH ST <br />SANTA ANA, CALIFORNIA 92706 <br />APN # 39905308 TEL #: (714) 975-0828 <br />CLIENT: <br />SIGNAGE <br />CSLB # 619149 CLASS: B, C-10 <br />NAME: GARY GIETZ, JACK MCCLARY <br />SIGNED: 8/30/2024 PHONE 310.904.6139 <br />ENERGY SERVICE PARTNERS <br />970 W 190TH ST, STE 302 <br />TORRANCE, CA 90502 <br />CONTRACTOR: <br />WEATHER RESISTANT PLASTIC PLACARD <br />PLACEMENT: MAIN PANEL (COVER) <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS AS SHOWN <br />CAUTION: <br />SIGNAGE <br /> WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE <br /> WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />! <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />! <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />(PER CODE: CEC 705.12(C), CEC 690.59) <br />LABEL LOCATION: MAIN SERVICE DISCONNECT <br />PER CEC 705.12(B)(3)(2) <br />LABEL LOCATION: <br />DC DISCONNECT, BREAKER, <br />RECOMBINER BOX <br />(PER CODE: CEC 690.13(B)) <br />[To be used when inverter is ungrounded] <br />LABEL LOCATION: <br />COMBINER BOX, BREAKER PANEL/PULL <br />BOXES, MAIN SERVICE DISCONNECT, AC <br />DISONNECT, POINTS OF CONNECTION <br />(PER CODE: CEC 706.15(C)(4),CEC 690.13(B)) <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL <br />LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, <br />PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN <br />DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) <br />INVERTER <br />LABEL LOCATION: <br />RAPID SHUTDOWN OR ON INVERTER IF RSD IS <br />INTEGRATED <br />CEC 690.56(C)(2) <br />RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br />931 W 18TH ST <br />SANTA ANA, CALIFORNIA 92706 <br />LABEL LOCATION: <br />AC DISCONNECT, INVERTER, POINT OF INTERCONNECTION, <br />BREAKER PANEL/PULL BOXES <br />(PER CODE: CEC 690.54) <br />SIGNAGE REQUIREMENTS: <br />·RED BACKGROUND <br />·WHITE LETTERING <br />·MINIMUM 3/8" LETTER HEIGHT <br />·ALL CAPITAL LETTERS <br />·ARIAL OR SIMILAR FONT, NON-BOLD <br />·REFLECTIVE WEATHER RESISTANT <br />MATERIAL SUITABLE FOR THE <br />ENVIRONMENT (DURABLE ADHESIVE <br />MATERIALS MUST MEET THIS <br />REQUIREMENT) <br />ADHESIVE FASTENED SIGNS: <br />·THE LABEL SHALL BE SUITABLE FOR <br />THE ENVIRONMENT WHERE IT IS <br />INSTALLED. <br />·WHERE REQUIRED ELSEWHERE IN <br />THIS CODE, ALL FIELD APPLIED <br />LABELS, WARNINGS, AND MARKINGS <br />SHOULD COMPLY WITH ANSI Z535.4 <br />[CEC 110.21(B) FIELD MARKING]. <br />·ADHESIVE FASTENED SIGNS MAY BE <br />ACCEPTABLE IF PROPERLY <br />ADHERED. VINYL SIGNS SHALL BE <br />WEATHER RESISTANT <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OPERATING CURRENT 28.1 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />(N) AC DISCONNECT <br />! <br />(N) IQ COMBINER BOX <br />LABEL LOCATION: <br />SERVICE DISCONNECTING MEANS <br />(PER CODE: CEC 690.56(C)) <br />SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID <br />SHUTDOWN <br />TURN RAPID <br />SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION <br />TO <br />SHUTDOWN PV <br />SYSTEM AND <br />REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR <br />ELECTRIC <br />PV PANELS <br />PHOTOVOLTAIC POWER SOURCE <br />SOLAR PV DC CIRCUIT <br />! <br />LABEL LOCATION: EMT/ CONDUIT RACEWAYS <br />PER CEC 690.31(D)(2) <br />LABEL LOCATION: EMT/ CONDUIT RACEWAYS <br />PER CEC 690.31(D)(2) <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER <br />PER CEC 690.13(B) <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />LABEL LOCATION: AC DISCONNECT, BREAKER, <br />POINT OF CONNECTION <br />PER CEC 690.13(B) <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT <br />(PER CODE: CEC 705.12(D)) <br /> CAUTION! <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />W <br />1 <br />8 <br />T <br />H <br /> <br />S <br />T <br />(N) IQ BATTERY <br />(E) MAIN PANEL <br />(N) SOLAR ARRAY <br />931 W Eighteenth <br />St10/18/2024