Laserfiche WebLink
PV-2.1REV: A 8/30/2024 <br />CONSUELO SMITH <br />931 W 18TH ST <br />SANTA ANA, CALIFORNIA 92706 <br />APN # 39905308 TEL #: (714) 975-0828 <br />CLIENT: <br />BATTERY SIGNAGE <br />CSLB # 619149 CLASS: B, C-10 <br />NAME: GARY GIETZ, JACK MCCLARY <br />SIGNED: 8/30/2024 PHONE 310.904.6139 <br />ENERGY SERVICE PARTNERS <br />970 W 190TH ST, STE 302 <br />TORRANCE, CA 90502 <br />CONTRACTOR: <br />SIGNAGE <br />SIGNAGE REQUIREMENTS: <br />·RED BACKGROUND <br />·WHITE LETTERING <br />·MINIMUM 3/8" LETTER HEIGHT <br />·ALL CAPITAL LETTERS <br />·ARIAL OR SIMILAR FONT, NON-BOLD <br />·REFLECTIVE WEATHER RESISTANT <br />MATERIAL SUITABLE FOR THE <br />ENVIRONMENT (DURABLE ADHESIVE <br />MATERIALS MUST MEET THIS <br />REQUIREMENT) <br />·ALL VOLTAGES SHALL BE ENGRAVED <br />NO HANDWRITTEN <br />ADHESIVE FASTENED SIGNS: <br />·THE LABEL SHALL BE SUITABLE FOR <br />THE ENVIRONMENT WHERE IT IS <br />INSTALLED. <br />·WHERE REQUIRED ELSEWHERE IN <br />THIS CODE, ALL FIELD APPLIED <br />LABELS, WARNINGS, AND MARKINGS <br />SHOULD COMPLY WITH ANSI Z535.4 <br />[CEC 110.21(B) FIELD MARKING]. <br />·ADHESIVE FASTENED SIGNS MAY BE <br />ACCEPTABLE IF PROPERLY <br />ADHERED. VINYL SIGNS SHALL BE <br />WEATHER RESISTANT <br />LOCATION: <br />BACKUP INTERFACE <br />MAIN BATTERY DISCONNECT <br />ENERGY STORAGE SYSTEM <br />AC DISCONNCT <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATIONS <br />EMERGENCY DISCONNECT <br />BATTERY STORAGE UNIT <br />CAUTION: BATTERY CIRCUIT <br />ENERGY <br />STORAGE <br />SYSTEM <br />DISCONNECT <br />LABEL LOCATION: <br />BATTERY DISCONNECT <br />(PER CODE: CEC 706.7(D)) <br />NOMINAL ESS AC VOLTAGE: <br />MAXIMUM ESS DC VOLTAGE: <br />AVAILIBLE FAULT CURRENT <br />DERIVED FROM THE ESS <br />DATE CALCULKATION PERFORMED: <br />N/A <br />8.30.24 <br />76.8 <br />86.4 <br />LABEL LOCATION: <br />BATTERY DISCONNECT <br />(PER CODE: CEC 706.7(D)) <br />WARNING <br />ENERGY STORAGE SYSTEM DISCONNECT ARC <br />FLASH AND SHOCK HAZARD <br />LOCATION: <br />ESSENTIAL LOAD CENTER <br />EMERGENCY RESPONSE PROCEDURE. <br />ONLY ESSENTIAL LOADS TO REMAIN <br />ENERGIZED. <br />Appropriate PPE and Tools required while working on this equipment <br />Refer to NFPA 70 E. <br />! WARNING TRI POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />THIRD SOURCE IS ESS SYSTEM <br />! <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />(PER CODE: CEC 705.12(C), CEC 690.59) <br />WEATHER RESISTANT PLASTIC PLACARD <br />PLACEMENT: MAIN PANEL (COVER) PER CEC 710.10 <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS AS SHOWN <br />CAUTION: MULTIPLE <br />SOURCES OF <br />POWER <br />931 W 18TH ST <br />SANTA ANA, CALIFORNIA 92706 <br />LOCATION: <br />SYSTEM AC DISCONNECT <br />F.D. – ELECTRICAL <br />BLDG DISCONNECT <br />#1 of 3 <br />LABEL LOCATION: <br />MIN. SIZE 2" X 3.5" ALL-WEATHER PLASTIC <br />WITH VERBIAGE ENGRAVED <br />MAIN SERVICE PANEL <br />LABEL LOCATION: <br />MIN. SIZE 2" X 3.5" ALL-WEATHER PLASTIC <br />WITH VERBIAGE ENGRAVED <br />ESS AC DISCONECT <br />F.D. – ELECTRICAL <br />BLDG DISCONNECT <br /># 2 of 3 <br />F.D. – ELECTRICAL <br />BLDG DISCONNECT <br /># 3 of 3 <br />LABEL LOCATION: <br />MIN. SIZE 2" X 3.5" ALL-WEATHER PLASTIC <br />WITH VERBIAGE ENGRAVED <br />PV AC DISCONNECT <br />#1 #2 #3 <br />Panel-interior Placards are required to be placed <br />inside a panel to identify specific switches/ <br />breakers when multiple switches within a single <br />panel/enclosure are required to be operated <br />(N) AC DISCONNECT <br />(N) IQ COMBINER BOX <br />(N) IQ BATTERY <br />(E) MAIN PANEL <br />(N) SOLAR ARRAY <br />W <br />1 <br />8 <br />T <br />H <br /> <br />S <br />T <br />931 W Eighteenth <br />St10/18/2024