01 <br />12 AWG PV WIRE, COPPER <br />6 AWG BARE, COPPER <br />FREE AIR <br />N/A <br />20A <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />MAX OUTPUT PER BRANCH (125%) <br />MODULES / MICROINVERTERS TO JUNCTION BOX <br />9B5 <br />B4 <br />9B6 <br />9 <br />01 02 <br />JU <br />N <br />C <br />T <br />I <br />O <br />N <br /> <br />B <br />O <br />X <br />NE <br />M <br /> <br />3 <br />R <br />, <br /> <br />U <br />L <br /> <br />L <br />I <br />S <br />T <br />E <br />D <br />B4 <br />B5 <br />B6 <br />MICROINVERTERS <br />BRANCH 4-6 <br />IQ COMBINER <br />W/ ENPHASE ENVOY <br />240/120 V 1Ø, 3W <br />20A <br />20A <br />20A <br />PV AC DISCONNECT <br />60A, 240V, NEMA 3R <br />VISIBLE/LOCKABLE <br />LABELLED ACD <br />3B <br />TO UTILITY GRID <br />(OVERHEAD) <br />M 400A <br />(E)125A <br />(E) 400A MAIN SERVICE PANEL <br />240/120 V 1Ø, 3W <br />BUS RATING: 400A <br />MCB RATING: 400A <br />INTERCONNECTION STRATEGY: <br />LOAD SIDE 705.12(B)(3)(2) <br />METER NUMBER: <br />222013-114661 <br />(E) GROUNDING <br />ELECTRODE <br />15A <br />ENVOY <br />COMMS <br />3B <br />50A <br />04 <br />COMMS <br />(E) 125A <br />SUB PANEL <br />240/120 V 1Ø, 3W <br />05 <br />60A <br />(N) FRANKLIN WH <br />AGATE <br />240/120 V 1Ø, 3W <br />MAIN BUS: 200A <br />(N) 100A BATTERY <br />SUB PANEL <br />240/120 V 1Ø, 3W <br />30A <br />30A <br />[x2] (N) BATTERIES <br />FRANKLINWH APOWER <br />CAPACITY: 13.6 kWH (EACH) <br />#1 <br />06 <br />COMMS <br />#2 <br />COMMS <br />CONDUCTOR: 10 AWG, THWN-2, Cu <br />GROUND:8 AWG, THWN-2, Cu <br />CONDUIT:0.75" EMT <br />06 <br />60A FUSES <br />VISIBLE/LOCKABLE <br />LABELED ACD <br />ESS AC DISCONNECT <br />60A FUSED <br />240V, NEMA 3R <br />9B2 <br />B1 <br />9B3 <br />10 <br />01 <br />02 <br />JU <br />N <br />C <br />T <br />I <br />O <br />N <br /> <br />B <br />O <br />X <br />NE <br />M <br /> <br />3 <br />R <br />, <br /> <br />U <br />L <br /> <br />L <br />I <br />S <br />T <br />E <br />D <br />B1 <br />B2 <br />B3 <br />MICROINVERTERS <br />BRANCH 1-3 <br />IQ COMBINER <br />W/ ENPHASE ENVOY <br />240/120 V 1Ø, 3W <br />20A <br />20A <br />20A <br />PV AC DISCONNECT <br />60A, 240V, NEMA 3R <br />VISIBLE/LOCKABLE <br />LABELLED ACD <br />3A <br />15A <br />ENVOY <br />COMMS <br />3A <br />(E) SUB PANEL <br />240/120 V 1Ø, 3W <br />BUS RATING: 125A <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />60A <br />125A <br />SUB MCB <br />(E)125A <br />(E)100A <br />BUILDING G <br />BUILDING H <br />PV SYSTEM COMPONENTS <br />INV1 <br />M MODULES (55) HANWHA QCELLS <br /> Q.TRON BLK M-G2+ 425 <br />MICROINVERTERS (55)ENPHASE IQ8A-72-2-US <br />[240] [SI1-JUN20] <br />PV COMPONENT NOTES <br />1. PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER CEC 690.12 <br />2. ENPHASE MICROINVERTERS ARE MODULE-LEVEL RSD COMPLIANT <br />02 <br />10 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />6 (2 PER BRANCH) <br />20A <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />MAX OUTPUT PER BRANCH (125%) <br />JUNCTION BOX TO PV BRANCH BREAKERS <br />8 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />3 <br />40.60A <br />50.75A <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />CONTINUES CURRENT <br />MAX CURRENT (125%) <br />3A IQ COMBINER TO SUB PANEL <br />8 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />3 <br />39.15A <br />48.94A <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />CONTINUOUS CURRENT <br />MAX CURRENT (125%) <br />3B IQ COMBINER TO AGATE <br />3 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />1" EMT <br />3 <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />04 AGATE TO MSP <br />1 AWG THWN-2, COPPER <br />6 AWG THWN-2, COPPER <br />EXITING <br />3 <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />05 AGATE TO SUB PANEL <br />INFINITY SOLAR, INC. <br />749 N MAIN ST. <br />ORANGE, CA 92868 <br />PHONE: (714) 880-8089 <br />LIC NO.: C10 - 824287 <br />TIM POLUJANCEWICZ <br />ELECTRICAL & CONDUIT NOTES <br />A. MAIN PANEL UPGRADES. A TYPE 1 OR TYPE 2 SURGE PROTECTION DEVICE <br />SHALL BE INSTALLED FOR THE NEW MSP EITHER AS AN INTEGRAL PART OF THE <br />SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO. <br />[NEC 230.67] <br />B. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR <br />PURPOSE. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON <br />MINIMUM CODE REQUIREMENT AND ARE NOT MEANT TO LIMIT UP-SIZING AS <br />REQUIRED BY FIELD CONDITIONS. <br />C. CONDUIT RACEWAYS SHALL BE PROVIDED WITH EXPANSION FITTINGS TO <br />COMPENSATE FOR THERMAL EXPANSION AND CONTRACTION. [NEC 110 (B) AND <br />110.14 (D)] <br />D. PROVIDE PULL BOXES AND/OR EXPANSION OR DEFLECTION FITTINGS FOR <br />THE ROOFTOP CONDUITS TO ACCOMMODATE THERMAL EXPANSION AND <br />CONTRACTION. [NEC 300.7(B)] <br />E. ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE INSTALLED A <br />MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR <br />CABLE OF 7/8" IN. (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). <br />F. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND <br />IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. [NEC <br />690.31(C) THROUGH (F), 310.10(D)] <br />G. EXPOSED CONDUCTORS WITHIN THE PV ARRAY SHALL BE PV WIRE/CABLE, <br />OR TYPE USE-2, OR TYPE RHW-2 (UL 4703 & 854 LISTED) [NEC 690.31(C)(1)] <br />H. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN TIGHT AND <br />APPROVED FOR USE IN WET LOCATIONS. (NEC 314.15) <br />I. DC WIRING INSIDE A BUILDING MUST BE IN METAL RACEWAYS, METAL-CLAD <br />CABLE, OR METAL ENCLOSURES. [NEC 690.31(D)] <br />J. EQUIPMENT GROUNDING CONDUCTOR (EGC) SMALLER THAN #6-AWG SHALL <br />BE PROTECTED FROM PHYSICAL DAMAGE BY AN IDENTIFIED RACEWAY OR <br />CABLE ARMOR, UNLESS INSTALLED WITHIN HOLLOW SPACES OF THE FRAMING <br />MEMBERS OF BUILDINGS OR STRUCTURES AND WHERE NOT SUBJECT TO <br />PHYSICAL DAMAGE. [NEC 250.120(C)] <br />K. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE <br />NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED. [NEC 300.4] <br />L. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE <br />REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY <br />FIELD CONDITIONS. <br />6 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />2 <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />06 BATTERY SUB PANEL TO AGATE <br />BATTERY BACKUP CALCULATIONS <br />BATTERY OUTPUT: 60A <br />PV OUTPUT (125%):50.75A <br />TOTAL OUTPUT:110.75A <br />MAX ALLOWED BACKFEED: <br />400A X 1.2 - 400A = 80A <br />80A < 110.75A (PCS REQ.) <br />BATTERY BACKUP CALCULATIONS <br />PV WIRE SCHEDULE <br />SEE CALCULATIONS PAGE FOR FULL WIRE AND CONDUIT CALCULATIONS <br />ADDITIONAL NOTES <br />DRAWN BY: <br />PAPER: 11X17 (ANSI B)DATE: <br />DESIGN LEAD: <br />DESIGNED BY SOLAR DEPLOYED, LLC. <br />931 10TH ST #114, MODESTO, CA 95354 <br />209-671-2001 | HELLO@SOLARDEPLOYED.COM <br />SIGNATURE: <br />CHECKED BY: <br />6/27/2024 <br />T.M. <br />E.V.A.B. <br />SHEET NAME: <br />NEW PV SYSTEM <br /> 23.375 kW DC (STC-DC) | 21.287 kW (CEC-AC) <br />SARAH HAMMARSTROM <br />403 N SUSAN ST, <br />SANTA ANA, CA 92703 <br />APN: 198-261-34 <br />SHEET NO.: <br />ENGINEER OF RECORD <br />LINE DIAGRAM PV.04 <br />B <br />403 N Susan St #G <br />& H10/21/2024