Laserfiche WebLink
DESIGN LOCATION AND TEMPERATURE <br />WEATHER STATION EL TORO MCAS <br />ASHRAE EXTREME LOW TEMP. 1°C <br />ASHRAE 2% HIGH TEMP.32.6°C <br />PV SYSTEM ELECTRICAL SPECIFICATIONS AND CALCULATIONS <br />MODULE SPECIFICATIONS <br />(55) HANWHA QCELLS Q.TRON BLK M-G2+ 425 <br />RATED POWER (PMAX) (W)425W <br />RATED POWER (PTC) (W)399W <br />SHORT CIRCUIT CURRENT (ISC) (A)13.66A <br />MAXIMUM POWER CURRENT (IMP) (A)12.98A <br />OPEN CIRCUIT VOLTAGE (VOC) (V)39V <br />MAXIMUM POWER VOLATGE (VMP) (V)32.7V <br />TEMP. COEFF. OF VOC -0.245%/°C <br />PV SYSTEM COMPONENTS <br />M <br />TOTAL SYSTEM SUMMARY <br />SYSTEM SIZE (STC-DC): 23.375 kW <br />SYSTEM SIZE (CEC-AC): 21.287 kW <br />INVERTER RATED POWER (AC): 19.195 kW <br />MAX PV CURRENT (125%):99.69A <br />INV1 <br />M MODULES (55) HANWHA QCELLS <br /> Q.TRON BLK M-G2+ 425 <br />MICROINVERTERS (55)ENPHASE IQ8A-72-2-US <br />[240] [SI1-JUN20] <br />PV COMPONENT NOTES <br />1. PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER CEC 690.12 <br />2. ENPHASE MICROINVERTERS ARE MODULE-LEVEL RSD COMPLIANT <br />MAX OCPD (A)20A <br />RATED POWER (W)349W <br />MAX OUTPUT (A)1.45A <br />MAX INPUT (A)15A <br />MAX INPUT (V)58V <br />EFFICIENCY (CEC)0.97% <br />SPECIFICATIONS <br />INV1 <br />BRANCH DETAILS B1 B2 B3 B4 B5 B6 <br />(55) ENPHASE IQ8A-72-2-US [240V] [JUN20-SI1] <br />MAX. OVERCURRENT CALCULATION: 1.45A X 55 = 79.75A; 79.75A X 125% = 99.69A MAX <br />MICROINVERTER RATIO [1:1]MICROINVERTER DETAILS <br />10 <br />10 <br />14.50A <br />18.13A <br />3490W <br />9 <br />9 <br />13.05A <br />16.31A <br />3141W <br />9 <br />9 <br />13.05A <br />16.31A <br />3141W <br />INVERTERS PER BRANCH <br />MODULE PER BRANCH <br />AC CURRENT <br />MAX AC CURRENT (125%) <br />MAX AC OUTPUT POWER <br />9 <br />9 <br />13.05A <br />16.31A <br />3141W <br />9 <br />9 <br />13.05A <br />16.31A <br />3141W <br />9 <br />9 <br />13.05A <br />16.31A <br />3141W <br />PV CONDUIT AND CONDUCTOR CALCULATIONS <br />8 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />3 <br />39.15A <br />48.94A <br />0.94 (32.6°C) <br />1.0 <br />55A <br />51.70A > 48.94A OK <br />50A @ 75°C <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />CONTINUOUS CURRENT <br />MAX CURRENT (125%) <br />TEMP. CORR. FACTOR <br />CONDUIT FILL FACTOR <br />BASE AMP <br />DERATED AMP <br />TERMINAL TEMP & AMP <br />3 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />1" EMT <br />3 <br />0.94 (32.6°C) <br />1.0 <br />115A <br />108.10A <br />100A @ 75C <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />TEMP. CORR. FACTOR <br />CONDUIT FILL FACTOR <br />BASE AMP <br />DERATED AMP <br />TERMINAL TEMP & AMP <br />1 AWG THWN-2, COPPER <br />6 AWG THWN-2, COPPER <br />EXITING <br />3 <br />0.94 (32.6°C) <br />1.0 <br />145A <br />136.30A <br />130A @ 75C <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />TEMP. CORR. FACTOR <br />CONDUIT FILL FACTOR <br />BASE AMP <br />DERATED AMP <br />TERMINAL TEMP & AMP <br />01 <br />TEMP. CORR. FACTOR <br />CONDUIT FILL FACTOR <br />BASE AMP @ 90C <br />DERATED AMP <br />TERMINAL AMP @ 75C <br />12 AWG PV WIRE, COPPER <br />6 AWG BARE, COPPER <br />FREE AIR <br />N/A <br />20A <br />0.76 (54.600000°C) <br />N/A <br />40A <br />30.40A > 20A OK <br />40A @ 90°C <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />MAX OUTPUT PER BRANCH (125%) <br />02 <br />TEMP. CORR. FACTOR <br />MAX. CONDUIT FILL FACTOR <br />BASE AMP @ 90C <br />MAX. DERATED AMP <br />TERMINAL AMP @ 75C <br />0.94 (32.6°C) <br />0.8 <br />40A <br />30.08A > 20A OK <br />35A @ 75°C <br />10 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />6 (2 PER BRANCH) <br />20A <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />MAX OUTPUT PER BRANCH (125%) <br />MODULES / MICROINVERTERS TO JUNCTION BOX <br />JUNCTION BOX TO PV BRANCH BREAKERS <br />8 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />3 <br />40.60A <br />50.75A <br />0.94 (32.6°C) <br />1.0 <br />55A <br />51.70A > 50.75A OK <br />50A @ 75°C <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />CONTINUES CURRENT <br />MAX CURRENT (125%) <br />TEMP. CORR. FACTOR <br />CONDUIT FILL FACTOR <br />BASE AMP <br />DERATED AMP <br />TERMINAL TEMP & AMP <br />3A IQ COMBINER TO SUB PANEL <br />05 AGATE TO SUB PANEL <br />04 AGATE TO MSP <br />3B IQ COMBINER TO AGATE <br />6 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />0.75" EMT <br />2 <br />0.94 (32.6°C) <br />1.0 <br />75A <br />70.50A <br />65A @ 75C <br />CONDUCTOR <br />GROUND <br />CONDUIT <br />CURRENT-CARRYING CONDUCTORS <br />TEMP. CORR. FACTOR <br />CONDUIT FILL FACTOR <br />BASE AMP <br />DERATED AMP <br />TERMINAL TEMP & AMP <br />06 BATTERY SUB PANEL TO AGATE <br />INFINITY SOLAR, INC. <br />749 N MAIN ST. <br />ORANGE, CA 92868 <br />PHONE: (714) 880-8089 <br />LIC NO.: C10 - 824287 <br />TIM POLUJANCEWICZ <br />DESIGN CALCULATIONS PV.05 <br />ADDITIONAL NOTES <br />DRAWN BY: <br />PAPER: 11X17 (ANSI B)DATE: <br />DESIGN LEAD: <br />DESIGNED BY SOLAR DEPLOYED, LLC. <br />931 10TH ST #114, MODESTO, CA 95354 <br />209-671-2001 | HELLO@SOLARDEPLOYED.COM <br />SIGNATURE: <br />CHECKED BY: <br />5/23/2024 <br />T.M. <br />E.V.A.B. <br />SHEET NAME: <br />NEW PV SYSTEM <br /> 23.375 kW DC (STC-DC) | 21.287 kW (CEC-AC) <br />SARAH HAMMARSTROM <br />403 N SUSAN ST, <br />SANTA ANA, CA 92703 <br />APN: 198-261-34 <br />SHEET NO.: <br />ENGINEER OF RECORD <br />403 N Susan St #G <br />& H10/21/2024