My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3300 S Bristol St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
3300 S Bristol St
>
3300 S Bristol St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:32:58 AM
Creation date
6/5/2025 7:32:46 AM
Metadata
Fields
Template:
Plan
Permit Number
101120542
Full Address
3300 S Bristol St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1 <br />E-1 SCALE: N.T.S. <br />ONE-LINE DIAGRAM <br />SHEET TITLE <br />JOB NAME <br />CA200040 -CHADEMO SWAP <br />TARGET T0250 <br />3300 S BRISTOL STREET <br />SANTA ANA, CA 92704 <br />ELECTRIFY AMERICA, LLC <br />2003 EDMUND HALLEY <br />DRIVE <br />SUITE 200 <br />RESTON, VA 20191 <br />CHECKED BY: RBH <br />REV DATE DESCRIPTION BY <br />1 3-26-24 S&S GA <br />ONE-LINE DIAGRAM <br />E-1 <br />TOTAL FLA <br />LOAD SUMMARY <br />FLA QTY <br />350 KW POWER CABINET <br />TOTAL LOAD <br />NOTES: <br />1.ALL ITEMS IN GREY ARE PART OF AN EXISTING EVCS SYSTEM. ITEMS IN BOLD ARE <br />PROPOSED. <br />2.NOT USED. <br />3.CONTRACTOR TO FIELD-VERIFY EXISTING CONDUITS AT THE COMMENCEMENT OF <br />CONSTRUCTION. CONTRACTOR TO REVIEW ROUTING (AS SHOWN IN PLANS) AND <br />CONFIRM THE ACTUAL ROUTING (IF DIFFERENT FROM PLANS) CONTACT THE <br />CONSTRUCTION MANAGER. <br />4.NOT USED. <br />5.(2) #10 CU AND (1) #10 CU GND AUX POWER IS REQUIRED TO HAVE ORANGE AND <br />BROWN 6" MINIMUM HEAT-SHRINK AT TERMINATIONS. <br />BTC CONDUIT AND WIRING SCHEDULE <br />FROM TO CONFIGURATION <br />UTILITY TRANSFORMER EXISTING <br />SWITCHBOARD EXISTING <br />EXISTING <br />SWITCHBOARD <br />EXISTING POWER <br />UNIT (EV CHARGER) <br />(3) 350 MCM CU (XHHW-2) + <br />(1) 1/0 CU (THWN-2) EGC <br />IN EACH OF (2) 3" EXISTING CONDUITS <br />EXISTING POWER UNIT <br />(EV CHARGER) <br />EXISTING DC <br />DISPENSER (POST) <br />DC POWER <br />(2) 350 MCM AL (XHHW-2) 1KV+ <br />(1) 1/0 CU (THWN-2) EGC <br />IN (1) 2 1/2" EXISTING CONDUIT <br />EXISTING POWER UNIT <br />(EV CHARGER) <br />EXISTNG DC <br />DISPENSER (POST) <br />DC POWER + <br />AUXILIARY POWER <br />(2) 350 MCM AL (XHHW-2) 1KV+ <br />(1) 1/0 CU (THWN-2) EGC + <br />(2) #10 AWG CU (XHHW-2) 1KV+ <br />(1) #10 AWG CU (THWN-2) EGC <br />IN (1) 2 1/2" EXISTING CONDUIT <br />EXISTING POWER UNIT <br />(EV CHARGER) <br />EXISTNG DC <br />DISPENSER (POST) <br />COMMUNICATION <br />(1) 6 STRAND, 62.5UM OR OM3 BUFFERED I/O <br />MM FIBER (ST/ST CONN) + <br />(1) 2 CONDUCTOR #16 AWG (TW/SH PAIR) + <br />(1) CAT 6 CABLE W/RJ45 CONNECTORS <br />IN (1) 1 1/2" EXISTING CONDUIT <br />1 <br />2 <br />3 <br />3A <br />4 <br />M <br />EXISTING <br />UTILITY <br />GROUND <br />(PER <br />UTILITY) <br />1600AF <br />1200AT <br />W/RELT <br />LSIG <br />INCOMING / <br />METERING SECTION <br />50 <br />A <br />3P <br />1 <br />EXISTING UTILITY EXISTING 1200A GE SWITCHBOARD 277/480V, 3ɸ, 4W 65KAIC WITH GROUND FAULT PROTECTION, NEMA 3RTRANSFORMER, <br />480/277V, 3ɸ, 4W <br />750KVA <br />GR <br />N <br />D <br />NE <br />U <br />T <br />40 <br />0 <br />A <br />F <br />35 <br />0 <br />A <br />T <br />3P <br />10 <br />0 <br />A <br />MA <br />I <br />N <br />20 <br />A <br />1P <br />XFMR <br />30KVA <br />480 <br />120/208V <br />MAIN BREAKER SECTION 277/480V DISTRIBUTION SECTION 120/208V DISTRIBUTION SECTION <br />30 <br />A <br />1P 30 <br />A <br />1P 30 <br />A <br />1P 40 <br />A <br />2P <br />FUTURE <br />BESS <br />EQUIPMENT <br />FUTURE <br />BESS <br />INVERTER <br />SP <br />A <br />C <br />E <br />SP <br />A <br />C <br />E <br />EXISTING GFCI <br />RECEPTACLE IN <br />WEATHERPROOF <br />IN USE <br />ENCLOSURE <br />EXISTING <br />LEVEL <br />2 <br />CHARGER <br />*1600A BUS**125A BUS* <br />60 <br />0 <br />A <br />F <br />60 <br />0 <br />A <br />T <br />3P <br />360 KW <br />POWER <br />UNIT <br />#2 <br />60 <br />0 <br />A <br />F <br />60 <br />0 <br />A <br />T <br />3P <br />DISPENSER <br />2 <br />360 KW <br />POWER <br />UNIT <br />#1 <br />DISPENSER <br />1B <br />2 <br />3 <br />4 <br />3 <br />3A <br />4 <br />PROPOSED <br />DISPENSER <br />1A <br />3A <br />5 <br />7 <br /> 6 <br />EXISTINGEXISTING <br />EXISTING POWER UNIT <br />(EV CHARGER) <br />PROPOSED DC <br />DISPENSER (POST) <br />DC POWER <br />(2) 350 MCM AL (XHHW-2) 1KV <br />(1) 1/0 CU (THWN-2) EGC <br />IN (1) 2 1/2" EXISTING CONDUIT <br />EXISTING POWER UNIT <br />(EV CHARGER) <br />PROPOSED DC <br />DISPENSER (POST) <br />DC POWER + <br />AUXILIARY POWER <br />(2) 350 MCM AL (XHHW-2) 1KV <br />(1) 1/0 CU (THWN-2) EGC <br />(2) #10 AWG CU (XHHW-2) 1KV <br />(1) #10 AWG CU (THWN-2) EGC <br />IN (1) 2 1/2" EXISTING CONDUIT <br />EXISTING POWER UNIT <br />(EV CHARGER) <br />PROPOSED DC <br />DISPENSER (POST) <br />COMMUNICATION <br />(1) 6 STRAND, 62.5UM OR OM3 BUFFERED I/O <br />MM FIBER (ST/ST CONN) <br />(1) 2 CONDUCTOR #16 AWG (TW/SH PAIR) <br />(1) CAT 6 CABLE W/RJ45 CONNECTORS <br />IN (1) 1 1/2" EXISTING CONDUIT <br />5 <br /> 6 <br />7 <br />03/26/2024 <br />VSE Project Number: U5038.0113.241 <br />ELECTRICAL ONLY <br />651 W. galena park blvd. ste. 101 <br />draper, Utah 84020 <br />phone (801) 990-1775 <br />www.vectorse.com <br />® <br />3300 S Bristol St <br />11/13/2024
The URL can be used to link to this page
Your browser does not support the video tag.